Valid

GB/T 9340-2009Methods for color measurement of fluorescent specimens (English PDF)

荧光样品颜色的测量方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 9340-2009 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 11, 2009

Implementation date

November 1, 2009

Scope

GB/T 9340-2009 is the English-translated version of 荧光样品颜色的测量方法.

GB/T 9340-2009 gives two ways of measuring the colour of fluorescent specimens, spectrophotometry and photoelectric integration, and the way the results are expressed.

It applies to the relative measurement of reflecting specimens emitting in the visible region, and not to electroluminescent, chemiluminescent or phosphorescent specimens, nor to fluorescence measured for chemical analysis.

It defines fluorescence and its excitation by ultraviolet or visible radiation, the whiteness meter and the colorimeter, both working under a simulated D65 source, and the spectral consistency factor, whose calculation is in normative Appendix A. Its tables give the relative spectral power distribution of CIE standard illuminant D65, the colour-matching functions and chromaticity coordinates of the CIE 1931 and 1964 observers and the tristimulus values of the perfect diffuser.

It replaces GB/T 9340-2001, was issued on 11 March 2009 and has applied since 1 November 2009.

Found what you need?

Document preview — GB/T 9340-2009

National Standard of the People's Republic of China

ICS
17.180.20
Classification
G 56
Replacing
GB/T 9340-2001

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and Definitions GB/T 5698 and established the following

Foreword

The standard reference ASTME991:1998 "Standard method for measurement of fluorescent samples color" and ASTME991:2006 "with a monochrome Measurement of the fluorescence color sample standard method ", and ASTME991:1998 and ASTME991:2006 are non-degree of consistency Equivalent. This standard ASTME991:1998 main differences are as follows.

--- Increasing the photoelectric integral measurement method; And ASTME991:2006 main differences are as follows.

1998 light consistency factor (SCF) of the definition and calculation; retain the use of SCF method sentence. --- ASTME991 Reserved Off the instrument light source and illuminant D65 consistent level of content.

This standard replaces GB/T 9340-2001 "Relative fluorescence measurement sample color." This standard compared with GB/T 9340-2001 The main changes are as follows.

--- Standard Chinese name was changed to "color sample fluorescence measurement method"; English name changed to "Methodsforcolormeas-urementoffluorescentspecimens ";

--- Terms and definitions added "light consistency factor" to increase the "ultraviolet excitation fluorescence" in the definition of fluorescence, the "visible fluorescence excitation" Content;

--- Edit "colorimeter Law" as "photoelectric integration", see Chapter 6; 5.2.4.2,5.2.4.3;

--- Modify the original standard 5.1.3 source level; increase consistent with the SCF process method to determine the light source and instrument of standard illuminant D65 Degree, see 5.2.1; increase SCF calculation method, see Appendix A;

--- 5.1.2 deletes the original standard, increasing standard colorimetric tristimulus values CIE1931 observer under the chromaticity coordinates and CIE whiteness meter Calculation formula, see equation (1), (3), (5), (6); calculating tristimulus values increased normalization coefficient k;

--- Increasing the CIE standard illuminant D65 relative spectral power distribution, CIE1931 standard colorimetric observer color matching functions and color products Coordinate, CIE1964 standard colorimetric observer color matching functions and color coordinates, completely diffuse reflector in the CIE standard illuminant D65 Tristimulus values and chromaticity coordinates, and are shown in Table 1, Table 2, Table 3, Table 4. Appendix A of this standard is a normative appendix.

The standard color by the National Standardization Technical Committee and centralized.

1 Scope

This standard specifies the color of fluorescent samples two measurement methods --- spectrum spectrophotometry, optical integration and measurement results indicate method.

This standard applies to relative measurements in the visible region of the light emitting reflection fluorescence sample color.

This standard does not apply to an electroluminescent samples, chemiluminescent sample and measuring the phosphorescent color sample; does not apply to chemical analysis applications Measuring fluorescence characteristics.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 3978 standard lighting and geometric conditions

GB/T 5698 color

ASTME308 Quality evaluation methods used in CIE Publication 51.2 chromaticity daylight simulator

3 Terms and Definitions

GB/T 5698 and established the following terms and definitions apply to this standard. terms The method of the object is calculated according to CIE color system

3.1 Fluorescence

Certain substances are or after exposure to radiation of a certain wavelength band, of the emitted light differs from the wavelength of irradiation, called fluorescence.

Called UV fluorescence produced after absorbing ultraviolet radiation excited fluorescence; fluorescence produced after absorbing visible radiation known as visible fluorescence excitation.

3.2 Fluorescent whitening agent

After absorption of shortwave ultraviolet radiation in the visible region of the emitted fluorescence, thereby increasing a chemical visual whiteness of the material.

3.3 Fluorescent whiteness meter

Samples for measuring fluorescence whiteness whiteness meter. Its main feature is to sample fluorescence measured under simulated standard illuminant D65 light source The whiteness.

3.4 For measuring

the fluorescence color sample tristimulus values or chromaticity coordinates colorimeter. Its main feature is to simulate measured in standard illuminant Chroma value of fluorescent samples under D65 light source.

3.5 Spectral consistency factor

Relative spectral sampling hole measuring instrument lighting relative spectral irradiance distribution curve CIE standard lighting and specific body points Cloth curves square root of the variance.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 9340

EditionTitleRevisionStatus
GB/T 9340-2009Methods for color measurement of fluorescent specimenscurrent editionCurrent
GB/T 9340-2001Methods for color measurement of fluorescent specimensprevious editionSuperseded

This page sells the current edition, GB/T 9340-2009. Earlier editions are listed for reference only.

How to Download GB/T 9340-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 9340-2009

$225.00