Valid

GB/T 9089.1-2021Electrical installations for outdoor sites under heavy conditions—Part 1: Vocabulary (English PDF)

户外严酷条件下的电气设施 第1部分:术语

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 9089.1-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 11, 2021

Implementation date

May 1, 2022

Scope

GB/T 9089.1-2021 is the English-translated version of 户外严酷条件下的电气设施 第1部分:术语.

GB/T 9089.1-2021 is the vocabulary part of the Chinese series on electrical installations for outdoor sites under heavy conditions, such as open-cut mines and quarries.

It defines the terms used across the series, from the sites themselves, electrical installations and electrical equipment to the normal operating area, the electrical operating area and the closed electrical operating area, and it covers operators, live parts, enclosures, barriers, conductors, overhead lines and working systems, with a new term for authorized personnel.

It has no normative references. It serves those who draft and revise standards and technical documents for these installations or prepare and translate professional manuals, and staff in the production, research and use of such equipment.

It replaces GB/T 9089.1-2008, was issued on 11 October 2021 and has applied since 1 May 2022.

Found what you need?

Document preview — GB/T 9089.1-2021

National Standard of the People's Republic of China

ICS
29.020
Classification
K 31
Replacing
GB/T 9089.1-2008

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.

This document is Part 1 of GB/T 9089 "Electrical Facilities under Harsh Outdoor Conditions". GB/T 9089 has released the following part.

---Part 1: Terminology;

---Part 2: General protection requirements;

---Part 3: General requirements for equipment and accessories;

---Part 4: Device requirements;

---Part 5: Operational requirements.

This document replaces GB/T 9089.1-2008 "Electrical facilities under severe outdoor conditions Part 1: Scope and definitions", and Compared with GB/T 9089.1-2008, in addition to structural adjustments and editorial changes, the main technical changes are as follows.

---Changed the name of the file;

--- Changed the description of the scope (see Chapter 1, Chapter 1 of the 2008 edition);

--- The explanation of "safety" and "protection" has been deleted (see Chapter 3, Chapter 3 of the 2008 edition);

---Changed the terms related to electrical equipment, three types of operators, live parts, shells, barriers, conductors, overhead lines, and working systems Definition (see 3.3, 3.4, 3.8, 3.9, 3.10, 3.17, 3.18, 3.19, 3.26, 3.27, 3.28, 3.31, 3.32, 3.33, 3.34, 3.43, 3.44, 3.45, 3.46, 3.47, 3.49, 3.50, 3.51, 3.58, 3.59, 3.63, the 2008 version of 3.3, 3.4, 3.10, 3.9, 3.8, 3.17, 3.16, 3.18, 3.25, 3.26, 3.27, 3.30, 3.31, 3.32, 3.33, 3.42, 3.43, 3.44, 3.46, 3.45, 3.48, 3.49, 3.50, 3.57, 3.58, 3.62);

---Added the terms and definitions of "authorized personnel" (see 3.11).

Introduction

GB/T 9089 "Electrical facilities under severe outdoor conditions" is to determine the It is formulated based on the requirements for the operation and installation of electrical equipment and systems, and generally includes the following electrical equipment and systems.

a) Mining, stacking and preliminary processing machinery;

b) Secondary processing machinery;

c) Conveying system;

d) Drainage and water supply system;

e) Mobile railway system;

f) Fixed railway system (only refers to operation);

g) Electric truck;

h) Power generation and distribution equipment;

i) Control, monitoring, signal and communication systems; j) Auxiliary equipment.

GB/T 9089 aims to provide guidelines for the installation and operation of electrical equipment and systems under severe outdoor conditions to ensure that The safety of the equipment and the normal operation of the equipment. GB/T 9089 is composed of five parts.

---Part 1: Terminology. The purpose is to give GB/T 9089 terms and definitions used in electrical installations under severe outdoor conditions.

---Part 2: General protection requirements. The purpose is to show that electrical facilities under normal operation and failure conditions under severe outdoor conditions, To ensure personal safety from electric shock protection and the selection requirements of protective devices and systems.

---Part 3: General requirements for equipment and accessories. The purpose is to provide electrical components, rotating motors, transformers under severe outdoor conditions General equipment, static converters, switching appliances, cables and related components, brake circuits, safety circuits, fire protection systems, etc. Require.

---Part 4: Device requirements. The purpose is to give requirements for mining, stacking and preliminary processing machinery and conveying systems.

---Part 5: Operational requirements. The purpose is to give the normal operating procedures to ensure personal safety.

This document is Part 1 of GB/T 9089, which defines the terms and definitions of electrical facilities under severe outdoor conditions.

1 Scope

This document defines the terms and definitions of electrical installations under severe outdoor conditions.

This document is suitable for the preparation and revision of electrical facilities standards under severe outdoor conditions, the preparation of technical documents, the preparation and translation of professional manuals, etc.

It is used by personnel in related departments such as production, scientific research, and use of electrical facilities under severe outdoor conditions.

2 Normative references

There are no normative references in this document.

3 Terms and definitions

3.1 Open-cut mine

An open site for mining materials or minerals such as coal, bauxite, iron ore, etc.

3.2 Quarry

An open field where materials such as limestone, stones, clay, etc. are excavated.

3.3 Electrical installation

The combination of related electrical equipment (3.4) has the characteristics of mutual coordination required to achieve a specific purpose. [Source: GB/T 2900.71-2008, 826-10-01, with modification]

3.4 Electrical equipment

Equipment used for power generation, transformation, transmission, distribution or utilization of electrical energy, such as motors, transformers, switchgear and control equipment, measuring instruments, Protection devices, wiring systems and electrical equipment. [Source: GB/T 2900.71-2008,826-16-01]

3.5 (Normal) operating area

A high-level direct contact protected electrical area accessible by the operator during the normal performance of his duties.

3.6 Electrical operating area

A medium-level direct contact protected electrical area that can only be accessed by opening the door or removing the barrier. This area should be clear and easy to see symbols of.

3.7 Closed electrical operating area

Electrical areas that can only be accessed with tools or keys or have a low level of direct contact protection with interlocking measures.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 9089.1

EditionTitleRevisionStatus
GB/T 9089.1-2021Electrical installations for outdoor sites under heavy conditions—Part 1: Vocabularycurrent editionCurrent
GB/T 9089.1-2008Electrical installations for outdoor sites under heavy conditions—Part 1: Vocabularyprevious editionSuperseded

This page sells the current edition, GB/T 9089.1-2021. Earlier editions are listed for reference only.

How to Download GB/T 9089.1-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 9089.1-2021