Scope

GB/T 7588.1-2020 is the English-translated version of 电梯制造与安装安全规范 第1部分:乘客电梯和载货电梯.

GB/T 7588.1-2020 is the Chinese safety code for building and installing passenger and goods-passenger lifts, traction and hydraulic, redrafted from ISO 8100-1:2019.

After a list of significant hazards it sets requirements for the well, the machine spaces and the pulley rooms, for landing and car doors with their strength, locking and emergency unlocking, for the car's available area, rated load and permitted number of passengers, for suspension ropes and their sheave diameter ratios, for safety gear, overspeed governors, rupture and throttle valves and the protection against ascending car overspeed and unintended car movement, and for guide rails, buffers, machines, electrical safety devices and programmable PESSRAL systems.

Clause 6 fixes design verification and pre-delivery testing, clause 7 the manuals and logbook. It partly replaces GB 7588-2003 and GB 21240-2007, was issued on 14 December 2020 and applies from 1 July 2022.

Found what you need?

Document preview — GB/T 7588.1-2020

National Standard of the People's Republic of China

ICS
91.140.90
Classification
Q 78

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • IntroductionXI
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 List of major hazards
  • 5 Safety requirements and/or protective measures
  • 5.1 General Rule
  • 5.2 Hoistway, machine space and pulley room
  • 5.2.1 General
  • 5.2.2 Access to the hoistway, machine space and passage between pulleys
  • 5.2.3 Access doors, safety doors, access trap doors and inspection doors
  • 5.2.4 Warning
  • 5.2.5 Hoistway
  • 5.2.6 Machine space and pulley room
  • 5.3 Landing doors and car doors
  • 5.3.1 General
  • 5.3.2 Height and width of entrance
  • 5.3.3 Sills, guides and door suspension mechanisms
  • 5.3.4 Horizontal spacing
  • 5.3.5 Strength of landing door and car door
  • 5.3.6 Protection related to door operation
  • 5.3.7 Local lighting and "car here" signal at landing
  • 5.3.8 Checking the locking and closing of landing doors
  • 5.3.9 Locking and emergency unlocking of landing doors and car doors
  • 5.3.10 Common requirements for verifying the locked state and closed state of landing doors
  • 5.3.11 Multiple sliding landing doors mechanically connected
  • 5.3.12 Closing of power-driven automatic landing doors
  • 5.3.13 Electrical safety device to verify that the car door is closed
  • 5.3.14 Multiple sliding or folding car doors mechanically connected
  • 5.3.15 Opening of the car door
  • 5.4 Car, counterweight and counterweight
  • 5.4.1 Car height
  • 5.4.2 The effective area, rated load and number of passengers of the car
  • 5.4.3 Car wall, car floor and car roof
  • 5.4.4 Car door, floor, car wall, ceiling and decorative materials
  • 5.4.5 Toe guards
  • 5.4.6 Car safety windows and car safety doors
  • 5.4.7 Car top
  • 5.4.8 Devices on the car top
  • 5.4.9 Ventilation
  • 5.4.10 Lighting
  • 5.4.11 Counterweight and counterweight
  • 5.5 Suspension devices, compensation devices and related protective devices
  • 5.5.1 Suspension device
  • 5.5.2 Rope diameter ratio of traction sheaves, pulleys and drums and wire rope or chain termination device
  • 5.5.3 Wire rope traction
  • 5.5.4 Winding of mandatory elevator wire rope
  • 5.5.5 Load distribution between wire ropes or chains
  • 5.5.6 Compensation device
  • 5.5.7 Protection of traction sheaves, pulleys, sprockets, overspeed governors and tensioners
  • 5.5.8 Traction wheels, pulleys and sprockets in the hoistway
  • 5.6 Measures to prevent falling, overspeed, accidental movement of the car and settlement of the car
  • 5.6.1 General
  • 5.6.2 Safety gear and its triggering device
  • 5.6.3 Rupture valve
  • 5.6.4 Throttle valve
  • 5.6.5 Pawl device
  • 5.6.6 Car upward overspeed protection device
  • 5.6.7 Accidental car movement protection device
  • 5.7 Rail
  • 5.7.1 Guidance of car, counterweight and counterweight
  • 5.7.2 Loads and forces
  • 5.7.3 Combination of load and force
  • 5.7.4 Impact factor
  • 5.7.5 Allowable stress
  • 5.7.6 Allowable deformation
  • 5.7.7 Calculation
  • 5.8 Buffer
  • 5.8.1 Car and counterweight buffer
  • 5.8.2 Travel of car and counterweight buffer
  • 5.9 Drive the host and related equipment
  • 5.9.1 General
  • 5.9.2 Drive host for traction and forced elevator
  • 5.9.3 Drive host of hydraulic elevator
  • 5.10 Electrical equipment (devices) and their connections
  • 5.10.1 General
  • 5.10.2 Input power terminal
  • 5.10.3 Contactors, contactor relays and safety circuit components
  • 5.10.4 Protection of electrical equipment
  • 5.10.5 Main switch
  • 5.10.6 Electrical wiring
  • 5.10.7 Lighting and socket
  • 5.10.8 Control of lighting and socket power
  • 5.10.9 Ground protection
  • 5.10.10 Mark
  • 5.11 Electrical fault protection, fault analysis and electrical safety devices
  • 5.11.1 Protection and fault analysis of electrical faults
  • 5.11.2 Electrical safety devices
  • 5.11.3 Elevator data information output
  • 5.12 Controls, limit switches and priority
  • 5.12.1 Elevator operation control
  • 5.12.2 Limit switch
  • 5.12.3 Emergency alarm device and intercom system
  • 5.12.4 Priorities and signals
  • 6 Verification of safety requirements and/or protective measures
  • 6.1 Technical compliance documents
  • 6.2 Design Verification
  • 6.3 Inspection before delivery
  • 6.3.1 General
  • 6.3.2 Braking system (5.9.2.2)
  • 6.3.3 Electrical equipment
  • 6.3.4 Traction inspection (5.5.3)
  • 6.3.5 Car safety gear (5.6.2)
  • 6.3.6 Counterweight or counterweight safety gear (5.6.2)
  • 6.3.7 Pawl device (5.6.5)
  • 6.3.8 Buffer (5.8.1 and 5.8.2)
  • 6.3.9 Rupture valve (5.6.3)
  • 6.3.10 Throttle valve or one-way throttle valve (5.6.4)
  • 6.3.11 Pressure test
  • 6.3.12 Car upward overspeed protection device (5.6.6)
  • 6.3.13 Leveling accuracy and leveling maintaining accuracy (5.12.1.1.4)
  • 6.3.14 Accidental car movement protection device (5.6.7)
  • 6.3.15 Protection measures for falling and shearing (5.3.9.3.4)
  • 7 Use information
  • 7.1 General
  • 7.2 Operation and Maintenance Manual
  • 7.2.1 General
  • 7.2.2 Normal use
  • 7.2.3 Maintenance
  • 7.2.4 Check
  • 7.3 Log
  • Appendix A (Normative Appendix) Electrical Safety Device Table
  • Appendix B (Informative Appendix) Technical Compliance Document
  • Appendix C (informative appendix) Periodic inspection
  • Appendix D (informative appendix) Entrance of machine space
  • Appendix E (informative appendix) Interface with buildings E 1 General
  • Appendix F (Normative Appendix) Ladder in and out of the pit F 1 Types of pit ladders
  • Reference

Foreword

GB/T 7588 "Safety Code for Elevator Manufacturing and Installation" is divided into the following parts.

---Part 1. Passenger elevators and freight elevators;

---Part 2. Design principles, calculations and inspections of elevator components.

This part is Part 1 of GB/T 7588.

This section was drafted in accordance with the rules given in GB/T 1.1-2009.

GB/T 7588.1 and GB/T 7588.2 replace GB 7588-2003 "Safety Code for Elevator Manufacturing and Installation" (including the first amendment Single) and GB 21240-2007 "Safety Code for Manufacturing and Installation of Hydraulic Elevators". This part is based on GB 7588-2003 and integrates The content of GB 21240-2007, compared with GB 7588-2003 and GB 21240-2007, except for structural adjustments and editorial changes. The main technical changes are as follows:

---Changed part of the content in the introduction;

---Added some terms and definitions;

---Added a list of major hazards;

---Added design principles for related hazards not covered in this section;

---The definition of machine space and its specific requirements have been added;

---Changed the lighting requirements of the shaft, engine room and pulley room;

---The location and quantity requirements of the pit stop devices have been changed, and the requirements for setting up pit maintenance operation control devices have been added;

---Changed the requirements for emergency relief;

---Changed the requirements for entering the pit;

---Changed the requirements for access doors, safety doors and inspection doors;

---Changed the setting requirements of the car and counterweight in the hoistway;

---Added the provisions of horizontal protrusions and horizontal beams protruding from the hoistway wall into the hoistway;

---The requirements for the minimum wall height of the partially enclosed hoistway and the distance from the moving parts of the elevator have been changed;

---Change the protection requirements of the space under the hoistway;

---Changed the barrier requirements for counterweight (or counterweight);

---Changed the requirements for barriers in the hoistway;

---Changed the requirements of the car top hazard space and the top floor spacing;

---Changed the requirements for pit avoidance space and spacing;

---The requirement for identifying the minimum engagement depth of the holding device at the bottom of the landing door and the car door has been added, and the requirements for the mechanical strength of the car door have been changed.

The hydraulic elevator has also changed the requirements of the mechanical strength of the landing door;

---The requirements for the protection device of the power-driven automatic door are changed;

---Added the position requirements of the triangular unlocking device;

---Added the requirement that the personnel in the pit can operate the locking device of the floor door;

---For hydraulic elevators, the requirements for opening the car door have been changed;

---The requirements for the effective area of the car have been changed;

---Relevant requirements for excess cargo elevators have been deleted;

---Added relevant requirements for the loading and unloading devices of cargo elevators;

---Changed the mechanical strength requirements of the car wall;

---The requirements for car structure and decoration materials have been changed;

--- Increased the rigidity requirements of the toe guard;

---The mechanical strength requirements of the car top have been changed, and the anti-skid requirements have been added;

---Change the requirements of the car top guardrail;

---The requirement for the upper guard plate of the car is deleted;

---The requirements for car lighting and emergency lighting have been changed;

---Added the requirement for identification of the number of heavy blocks;

---Change the regulations of wire rope termination device;

---Change the regulations of wire rope traction;

---Added the requirements for the safety factor of the compensation device;

---Added the requirements of the wire rope anti-drop groove device;

---Added the requirements for traction wheels, pulleys and sprockets in the hoistway;

---Added the load condition and release method of the release safety gear;

--- Deleted the "clamping device" provisions in the anti-settling measures of hydraulic elevator machinery;

---Deleted the provision of specially designed speed limiter for elevators with large rated load and low rated speed;

---The regulation of the speed limiter of the counterweight (or counterweight) safety gear has been changed;

---Changed the requirements for inspection and adjustment of the rupture valve;

---Added the effective working condition requirements of the car's upward overspeed protection device and the self-monitoring requirement of using the brake as the deceleration component;

---Changed the requirements for the speed monitoring components and movement speed of the car's upward overspeed protection device;

---Changed the requirements for the position of the car's upward overspeed protection device;

---For traction and forced elevators, the accidental movement protection device of the car is changed to adopt the brake as the self-monitoring of the stopping component Requirements. For hydraulic elevators, the requirements for accidental car movement protection devices have been added;

---The requirements for the force acting on the guide rail are changed;

---Changed the method of guide rail calculation;

---Added the requirement of the maximum peak deceleration of the non-linear buffer;

---Changed the provisions of the buffer reduction stroke design;

---The requirement of driving the main engine brake has been changed, and the requirement of monitoring the brake has been added;

---Added the requirement of moving to nearby landings when manually releasing the brake;

---Changed the requirements of static components for motor power supply and control;

---Change the requirements of electromagnetic compatibility;

---Added the requirements for electric shock protection;

---Changed the requirements for contactors and contactor relays;

---Changed the requirements after the hydraulic elevator overheating protection action;

---Changed the power supply requirements of the sockets required for the car roof, machine room, pulley room and pit;

---Added the provisions of the programmable electronic system (PESSRAL) related to elevator safety;

---Added the regulations for elevator data output;

---For hydraulic elevators, the requirements for leveling accuracy and leveling maintenance accuracy are increased;

---Changed the car overload regulations;

---Changed the requirements for overhaul operation control;

---Changed the speed requirements for maintenance operation and emergency electric operation;

---Deleted the regulation of "docking operation" control of freight elevator;

---Added protection requirements for maintenance operations;

---Added the regulations for the bypass device of the landing door and car door;

---Added the requirement to prevent the normal operation of the elevator when the door contact circuit fails;

---Increase the verification method of safety requirements and (or) protective measures;

---Change the requirements for inspection before delivery;

---Added the content of the machine space entrance;

---Added the content of the interface with the building;

---Added the requirement of entering the pit ladder.

This part uses the redrafting law to amend and adopt ISO 8100-1:2019 ``Elevators for Carrying People and Goods Part 1. Passenger Elevators And cargo passenger elevator.

Compared with ISO 8100-1:2019, this part has made the following structural adjustments.

---In 5.2.5.2.2.2b), 5.2.6.6.2c), 5.3.4.3, 5.4.3.2.2a), 5.4.4, 5.5.7, 5.6.7.6, 5.7.2.2, 5.7.2.3. 3. 5.7.2.

In 3.5, 5.7.2.3.6, 5.9.2.3.4, 5.9.3.9.1.1, 5.12.1.7, Appendix B, Appendix C, E 1 and E 3.2, clauses have been added Number for easy application;

---The 5.7.4.5, 5.7.4.6, and 5.7.4.7 clause numbers were revised to 5.7.5, 5.7.6, and 5.7.7 respectively, and editorial errors were corrected to facilitate application;

---In 6.3, the number and title of the suspended paragraph have been added, that is, "6.3.1 General Provisions", and the number of subsequent clauses has been adjusted to comply with GB/T 1.1-2009 regulations and ease of application;

---Renumbered some formulas to meet the requirements of GB/T 1.1-2009.

The technical differences between this part and ISO 8100-1:2019 and the reasons are as follows:

---Regarding normative reference documents, this section has made adjustments with technical differences to adapt to my country's technical conditions and adjustments.

The situation is collectively reflected in Chapter 2 "Normative Reference Documents", and the specific adjustments are as follows:

- Replace ISO 1219-1 with GB/T 786.1 which is equivalent to adopting international standards;

- Replace IEC 60529 with GB/T 4208 which is equivalent to adopting international standards;

- Replace IEC 60617 with GB/T 4728 (all parts) that is equivalent or modified to adopt international standards;

- Replace IEC 60245-5 with GB/T 5013.5, which is equivalent to adopting international standards;

- Replace IEC 60227-6 with GB/T 5023.6 which is equivalent to adopting international standards;

- Replace ISO 8100-2 with GB/T 7588.2-2020 which is modified to adopt international standards;

- Replace ISO 4344 with GB/T 8903, which is modified to adopt international standards;

- Replace IEC 60947-4-1 with GB/T 14048.4-2010 modified to adopt international standards;

- Replace IEC 60947-5-1 with GB/T 14048.5-2017 modified to adopt international standards;

- Replace IEC 60947-5-5 with GB/T 14048.14 which is equivalent to the international standard;

- Replace IEC 60664-1 with GB/T 16935.1 which is equivalent to adopting international standards;

- Replace IEC 61310-3 with GB/T 18209.3 which is equivalent to adopting international standards;

- Replace IEC 61810-1 with GB/T 21711.1 which is equivalent to adopting international standards;

- Replace EN13501-1 with GB 8624;

- Replace EN13015 with GB/T 18775;

- Replace EN81-28 with GB/T 24475;

- Replace EN81-58 with GB/T 24480;

- Replace ISO 22199 with GB/T 24807;

- Replace ISO 22200 with GB/T 24808;

- Added references to GB/T 3639, GB 4053.1, GB 4053.2, GB/T 13793, GB/T 24476-2017, GB/T 27903,

GB/T 32957, GB 50017, GA494 and JB/T 8734.6;

- Deleted ISO 3008-2, ISO 29584:2015, EN1993-1-1, EN10305 (all parts), EN12385-5 and EN50214.

---In terms of 3.4 "balance weight", 3.20 "installation unit", 3.21 "instantaneous safety gear" and 3.50 "safety parts", the definitions are modified Righteousness to suit our national conditions.

---In 5.2.1.5.1a)3), replace with "a stop device at a height of 1.10m~1.30m from the pit ground" "Set a stop device at a height of 1.2m from the pit ground" to improve operability.

---In 5.2.2.3, delete the relevant content that is allowed to pass through the private space for maintenance and rescue, in order to improve safety requirements and Workability.

--- In 5.2.2.5d), use "The distance between the back of the running stick and the wall should not be less than 200mm, and no "Should be less than 150mm" instead of "The distance between the back of the running stick and the wall should not be less than 0.15m" in order to be in line with GB/T 17888.4- The provisions of 4.4.4 in 2008 are consistent.

---In 5.2.3.1, the regulation when the distance between two adjacent door sills is greater than 11m is modified to meet the requirements of my country's high-rise building development Needs of development.

--- In 5.2.3.3e), "non-porous, meeting the requirements of relevant building fire protection codes" replaced "non-porous, meeting the same requirements as landing doors Mechanical strength requirements, and meet the requirements of relevant building fire protection regulations," to improve operability and suit my country's national conditions.

--- In 5.2.5.2.2.2b)1), 5.2.5.3.2b)1) and 5.4.7.1a), "permanent deformation is not greater than 1mm" instead of "no permanent deformation" "Shape" is more scientific and reasonable.

---In 5.2.5.2.3b) and Figure 2, the minimum wall height of partially enclosed hoistway and the distance from elevator moving parts have been revised. To improve safety requirements and operability.

---In 5.2.5.7.1 and 5.2.5.8.1, "In addition, a green frame with a width of not less than 100mm shall be used to mark each The edge of the vertical projection of the avoidance space" to improve safety requirements and operability.

--- In 5.2.5.8.1, the specific requirements for flexible parts to enter the hazard space have been added to improve operability.

--- In 5.3.5.3.2, the requirement to set the minimum meshing depth sign or mark is added to improve safety requirements and operability.

--- In Table 5 and Figure 11, according to 5.3.5.3.4 provisions have been modified to make the provisions consistent with the relevant requirements of the chart.

--- In 5.3.9.3.2, "only authorized personnel can obtain" has been added to improve safety requirements and suit my country's national conditions.

---In 5.3.14.1, "No need to consider the simultaneous damage of the upper and lower guides", in order to coordinate with 5.3.11.1 Suitable for my country's national conditions.

--- In 5.4.4.2, the provisions of car door decoration materials have been added to improve safety requirements.

--- In 5.4.4.3, the regulations for mirrors and other glass decorations used in the car have been modified to improve operability and suit my country National conditions.

--- In 5.4.11.2, "Should have measures to quickly identify the number of counterweights (for example. indicating the number or total height of counterweights) Degree, etc.)" to improve safety requirements and operability.

---In 5.5.2.3.1, "or other devices with equivalent safety" have been added to suit my country's national conditions.

--- In 5.6.1.3, the provisions of the hydraulic elevator counterweight fall protection measures have been added to improve safety requirements.

---In 5.6.2.2.1.2, the regulation of the maximum distance between the operating points of the overspeed governor corresponding to the movement of the overspeed The provisions of 5.3.2.3.1 in GB/T 7588.2-2020 are harmonized.

--- In 5.6.2.2.1.3c), the "nominal diameter of the overspeed governor rope should not be less than 6mm" has been added to improve safety requirements.

---In 5.6.6.2 and 5.6.7.3, the regulations in the case of using the main engine brake are modified to improve safety requirements and fitness In line with our national conditions.

--- In 5.7.2.1.2, 5.7.2.3.5 and 5.7.6, the regulations on the calculation of guide rails have been modified to make the relevant safety requirements more reasonable.

---In 5.9.2.2.2.1, the provision of monitoring brakes has been added to improve safety requirements.

---In 5.9.2.2.2.6, the warning information about replacement of worn brake pads has been added to improve safety requirements.

--- In 5.9.3.3.3.3, the requirement to indicate "allowable bending radius" is added to improve safety requirements.

---In 5.11.3, the regulation of elevator data information output was added to improve safety requirements and meet the needs of elevator technology development. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 230 pages — is available in the English PDF.

Referenced standards

Editions of GB/T 7588.1

EditionTitleRevisionStatus
GB/T 7588.1-2020Safety rules for the construction and installation of lifts - Part 1: Passenger and goods passenger lifts—Current
GB 21240-2007Safety rules for the construction and installation of hydraulic lifts—Superseded

This page sells the current edition, GB/T 7588.1-2020. Earlier editions are listed for reference only.

How to Download GB/T 7588.1-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation.

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
230 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 7588.1-2020

$3,260.00