GB/T 7409.2-2020Excitation systems for synchronous machines—Part 2: Models for power system studies (English PDF)

同步电机励磁系统 第2部分:电力系统研究用模型

Preview PDF

This is a limited preview

Buy now to download the full PDF (61 pages)

Need quotation for your management?

Get a formal quotation for GB/T 7409.2-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 2, 2020

Implementation date

January 1, 2021

Scope

GB/T 7409.2-2020 is the English-translated version of 同步电机励磁系统 第2部分:电力系统研究用模型.

GB/T 7409.2-2020 is the Chinese standard "Excitation systems for synchronous machines - Part 2: Models for power system studies".

Its scope clause reads: This Part of GB/T 7409 specifies the simulation diagram of the excitation system, the mathematical model of the exciter and control functions, and the terminology definitions of its related parameters and variables.

This Part is applicable to the excitation system models of steam (gas) turbine generators, hydroelectric generators, pumped storage power generators / motors and nuclear power units used in the power system studies and analysis.

Its clauses include terms and definitions; mathematical models of control functions; excitation system models; terminology; classification of exciters - graphical method and.

It was issued by the State Administration for Market Regulation on JUNE 2, 2020 and took effect on DECEMBER 1, 2020.

Found what you need?

Document preview — GB/T 7409.2-2020

National Standard of the People's Republic of China

ICS
29.160.20
Classification
K 21
Replacing
GB/T 7409.2-2008

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword4
  • Introduction6
  • 1 Scope8
  • 2 Normative References8
  • 3 Terms and Definitions8
  • 4 Classification of Exciters - Graphical Method and Mathematical Model for Stability Studies9
  • 4.1 DC Exciters9
  • 4.2 AC Exciters10
  • 4.3 Potential Source Static Exciter15
  • 4.4 Compound Source Static Exciter16
  • 5 Mathematical Models of Control Functions17
  • 5.1 Voltage Measurement and Load Current Compensation Link Model17
  • 5.2 Proportional-integral-derivative (PID) Correction Link Model19
  • 5.3 Excitation Feedback Link Model20
  • 5.4 Amplitude Limiting Link21
  • 5.5 Power System Stabilizer Model21
  • 5.6 General Structure of Main Voltage Control22
  • 5.7 Auxiliary Limiter Model23
  • 5.8 Mode of Auxiliary Limiter's Intervention in Main Voltage Control27
  • 6 Excitation System Models28
  • 6.1 Overview28
  • 6.2 Excitation System Models for AC Exciters28
  • 6.3 Excitation System Models for DC Exciters31
  • 6.4 Static Excitation System Model31
  • 7 Terminology33
  • 7.1 Parameters33
  • 7.2 Variables36
  • Appendix A (informative) Transformer High-voltage Side Voltage Control Model39
  • Appendix B (normative) Amplitude Limiting Expression Method40
  • Appendix C (informative) Multi-band Power System Stabilizer Model44
  • Appendix D (normative) Inverse Time Characteristic Calculation46
  • Appendix E (informative) UEL Model Table Lookup Function48
  • Appendix F (informative) Integral Reset Representation49
  • Appendix G (normative) Saturation Function50
  • Appendix H (normative) Rectifier Regulation Characteristics51
  • Appendix I (informative) Estimation of Over Excitation Limiter (OEL) Reference Value53
  • Appendix J (normative) Per-unit System60
  • Bibliography61

1 Scope

This Part of GB/T 7409 specifies the simulation diagram of the excitation system, the mathematical model of the exciter and control functions, and the terminology definitions of its related parameters and variables.

This Part is applicable to the excitation system models of steam (gas) turbine generators, hydroelectric generators, pumped storage power generators / motors and nuclear power units used in the power system studies and analysis.

2 Normative References

The following documents are indispensable to the application of this document. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.

GB/T 7409.1 Excitation Systems for Synchronous Electrical Machines - Definitions

3 Terms and Definitions

The terms and definitions defined in GB/T 7409.1, and the following are applicable to this document.

3.1 Main voltage control

The link of comparing the actual measured value of the synchronous generator terminal voltage with the given value and adjusting the excitation output with appropriate control rules in accordance with its deviation.

NOTE: its main functions also include load current compensation, excitation feedback link and power system stabilizer (PSS) functions.

3.2 Auxiliary limiters

The limiting link in the excitation regulator other than the main voltage control.

NOTE: it includes V/Hz limiter, over excitation limiter, maximum current limiter, stator current limiter and under excitation limiter, etc.

3.3 Maximum current limiter

Under any operating conditions, the output current of the excitation system is instantaneously limited to not exceed the specified maximum value.

3.4 Volts per hertz limiter; VEL

An additional unit or function in a voltage regulator that prevents the voltage-to-frequency ratio of a synchronous machine or its connected transformer from exceeding an allowable range.

3.5 Over excitation limiter; OEL

An additional unit or function in a voltage regulator that limits the output current of the excitation system to an allowable value.

3.6 Stator current limiter; SCL

An additional unit or function in a voltage regulator that limits the stator current within an allowable value by adjusting the reactive component of the stator current of the synchronous generator during over excitation or under excitation.

3.7 Under excitation limiter; UEL

An additional unit or function in a voltage regulator that limits the reactive power of the synchronous generator to no less than a specified value under different active loads.

4 Classification of Exciters - Graphical Method and Mathematical Model for Stability Studies

4.1 DC Exciters

In recent years, although DC exciters have been rarely used in new units, some synchronous machines are still equipped with such exciters. Figure 2 is a schematic diagram of an DC exciter using separately excited windings, and Figure 3 demonstrates the model of the exciter. In the model, the constant KE of the self-excited magnetic field of the AC and DC exciters is used to describe the characteristics of the exciter with self-excited components. Please be noted that when adopting the separately excited exciters, KE = 1.

XE---rectifier load factor, which is proportional to the commutation reactance of the voltage source and current source, or the combined equivalent commutation reactance of the voltage and current source, see Appendix H. Fe---commutation pressure drop coefficient, see Appendix H. Xgamma---commutation reactance. KI---current loop input constant. KP---voltage loop input constant.

Uf max, Uf min---maximum and minimum voltage output by the excitation system.

Ur max, Ur min---maximum and minimum output of the regulator UFE max---exciter magnetic field current limiting parameter.

UP+, UP----at the rated voltage of the generator, the maximum and minimum no-load output voltage of the potential source exciter. KG---feedback gain of the inner loop magnetic field regulator. KR---gain of voltage measurement link.

KZ---static difference compensation coefficient of the control link, which is generally set to the reciprocal of the proportional gain KS of the control link. TR---time constant of terminal voltage converter and load current compensator. XP---rectifier load factor of potential source converter, see Appendix H. KMAX---proportional gain constant coefficient, which is generally set to 1,000,000.

KA, KA1, KFF, KV, KAP, KAD, KAI, KB, KBP, KBI---voltage regulator gain constant. KF, KH---gain constant of excitation feedback link.

TB1, TB2, TC1, TC2, TA, TB, TAD, TG---voltage regulator time constant. TF---time constant of excitation feedback link. XC, RC---current and power compensator gain constants.

UA max, UA min, UA1 max, UA1 min, UA2 max, UA2 min, UB max, UB min, UD max, UD min, UI max, UI min---voltage regulator amplitude limiting values.

KL1---over excitation instantaneous limit gain.

UL1R---over excitation instantaneous setting value. KPSS, KS1, KS2, KS3---power system stabilizer gain.

TS1, TS2---time constant of power system stabilizer signal measurement link.

TW1, TW2, TW3, TW4---time constant of DC blocking link of power system stabilizer.

TP1, TP2, TP3, TP4, TP5, TP6, TP7, TP10, TP11---power system stabilizer time constant. A1, A2, M, N, TP8, TP9---power system stabilizer filter parameters. USS max, USS min---power system stabilizer output amplitude limiting values.

USI1 max, USI1 min, USI2 max, USI2 min---power system stabilizer input amplitude limiting values.

UfB, IfB, RfB UefB, IefB, RefB---respectively: generator magnetic field voltage, field current and field winding resistance reference value, exciter field voltage, field current and field winding resistance reference value.

UVF_REF---fixed value amplitude limiting value (expressed by the per-unit value of the rated value). Kinv, Kcool---heat accumulation and heat dissipation integral coefficient. KexpVEL---inverse time characteristic exponential coefficient of V/Hz limiter.

UVFL_th---inverse time timing start setting value of V/Hz limiter (expressed by the per-unit value of the rated value).

UVFL_rth---action return fixed value of V/Hz limiter (expressed by the per-unit value of the rated value).

UREF max---output maximum setting value of V/Hz limiter (expressed by the per-unit value of the rated value). KexpOEL---inverse time characteristic exponential coefficient of OEL limiter.

Ifth---inverse time limit timing start setting value of OEL limiter (expressed by the per-unit value of the rated value, and the setting value setting can be found in Appendix I).

Ifn---heat accumulation rotor current reference value of OEL limiter (expressed by the per-unit value of the rated value, and the setting value setting can be found in Appendix I).

Ifrth---inverse time limit setting value of OEL (expressed by the per-unit value of the rated value, and the setting value setting can be found in Appendix I).

If max---maximum magnetic field current setting value allowed by OEL (expressed by the per-unit value of the rated value, and the setting value setting can be found in Appendix I). C---upper amplitude limiting value of heat accumulation integral.

P, Q---active power and reactive power of the generator (expressed by the per-unit value of the apparent rated value).

IP, IQ---active current and reactive current of the generator (expressed by the per-unit value of the apparent rated value). delta---generator power angle.

Ue---exciter voltage after commutation reactance (expressed by the per-unit value of the generator air gap magnetic field voltage).

UREF---voltage regulator setting value (determined in accordance with the initial conditions). Upss---output of power system stabilizer.

Upss1, Upss2, Upss3---outputs of the power system stabilizer intervening in the main voltage control at different positions. UERR---deviation signal of the voltage control channel. Uess---output of excitation feedback link. Uie---a signal proportional to the exciter magnetic field current. UC---voltage measurement and compensator output. UA---output of voltage correction link.

USI1, USI2---input signals of power system stabilizer. fG---generator frequency (expressed by the per-unit value of power frequency 50 Hz). UVF_REF---fixed value output of V/Hz limiter. UVFL---output of V/Hz limiter.

UVFL1, UVFL2, UVFL3---outputs of V/Hz limiter intervening in the main voltage control at different positions. SOEL---OEL action flag bit (expressed by 0 and 1). UOEL---inverse time limit output of OEL limiter.

UOEL1, UOEL2, UOEL3, UOEL4, UOEL5---outputs of OEL limiter intervening in the main voltage control at different positions.

USCL1, USCL2---outputs of SCL limiter adopting the superposition mode to intervene in the main voltage control at different positions.

USCLind, USCLcap---SCL delayed phase side limit output and advanced phase side limit output.

Appendix J (normative)

Per-unit System In power system studies, the voltage and current of the generator and exciter, as well as the input and output quantities of the regulator are expressed by per-unit values. The per-unit system shall be established in accordance with the following requirements:

a) The per-unit value is equal to the actual value divided by the reference value.

b) The reference value of the generator voltage is the generator rated voltage. The reference value of the generator current is the generator rated current. The reference value of the generator power is the rated apparent power of the generator. The reference value of the generator frequency is the generator rated frequency.

c) The reference value IfB of the generator magnetic field current is the magnetic field current required to generate the rated voltage on the generator's no-load characteristic air gap curve. The reference value RfB of the generator magnetic field winding resistance is the generator's rated magnetic field voltage divided by the generator's rated magnetic field current. Under certain circumstances, the influence of the loop resistance needs to be considered. The reference value UfB of the generator magnetic field voltage is the reference value of the magnetic field current multiplied by the reference value of the magnetic field winding resistance.

d) The reference values of the output current and voltage of the exciter are respectively the reference values of the generator magnetic field current and voltage.

e) The reference value IefB of the exciter magnetic field current is the exciter magnetic field current value required to generate a per-unit value of generator magnetic field voltage on the air gap curve of the exciter no-load characteristic curve. The reference value RefB of the exciter magnetic field winding resistance is the resistance of the excitation circuit of the exciter under the rated operating conditions of the generator.

The reference value UefB of the exciter magnetic field voltage is the reference value of the exciter magnetic field current multiplied by the reference value of the exciter magnetic field winding resistance.

f) The reference values of the input voltage, current and power of the regulator are equal to the reference values of the generator voltage, current and power. When controlling the generator magnetic field voltage, the reference value of the regulator output voltage is equal to the reference value of the generator magnetic field voltage. When controlling the exciter magnetic field voltage, the reference value of the regulator output voltage is equal to the reference value of the exciter magnetic field voltage. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 61 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 7409.2

EditionTitleRevisionStatus
GB/T 7409.2-2020Excitation systems for synchronous machines—Part 2: Models for power system studiescurrent editionCurrent
GB/T 7409.2-2008Excitation systems for synchronous machines—Part 2: Models for power system studiesprevious editionSuperseded

This page sells the current edition, GB/T 7409.2-2020. Earlier editions are listed for reference only.

How to Download GB/T 7409.2-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
61 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 7409.2-2020

$490.00