GB/T 5598-2015Test method for thermal conductivity of beryllium oxide ceramics (English PDF)
氧化铍瓷导热系数测定方法
This is a limited preview
Buy now to download the full PDF (27 pages)
Need quotation for your management?
Get a formal quotation for GB/T 5598-2015 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
May 15, 2015
Implementation date
January 1, 2016
Scope
GB/T 5598-2015 is the English-translated version of 氧化铍瓷导热系数测定方法.
GB/T 5598-2015 is the Chinese standard "Test method for thermal conductivity of beryllium oxide ceramics". Its scope clause reads: This standard specifies the determination of beryllium oxide ceramic material thermal conductivity (thermal conductivity) of the club shaft and laser flashing method.
This standard specifies the method for measuring rod axis beryllium oxide ceramic temperature of the thermal conductivity in the range of 40 °C ~ 150 °C. This method can also Suitable for measuring other low thermal conductivity ceramic material or a ceramic matrix composite material thermal conductivity within the above temperature range.
Laser specified in this standard Flash method is suitable for the thermal diffusivity and thermal conductivity measurements in the range from room temperature to 1400 °C porosity of less than 10% of beryllium oxide ceramic material rate.
This method is also applicable in the above temperature range in the measurement of thermal diffusivity 10-7 m2/s ~ 10-3 m2/s between completely homogeneous , The energy pulse opaque other solid materials thermal diffusivity and thermal conductivity; suitable for measuring non-uniform or anisotropic material. Its clauses include terms and definitions.
Found what you need?
Document preview — GB/T 5598-2015
National Standard of the People's Republic of China
- ICS
- 31.030
- Classification
- L 90
- Replacing
- GB 5598-1985
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4.1 General
- 4.3 Principle of the laser flash method
- 5 club shaft Act
- 5.1 Test Instruments
- 5.2 Sample
- 5.3 Sample assembly
- 5.4 Test Procedure
- 5.5 Data Analysis
- 5.6 Test Report
- 6 8 the laser flash method
- 6.1 Principle
- 6.1.2 Test principle thermal diffusivity of
- 6.2 Measurement environment
- 6.3 Test Instrument
- 6.3.1 Thermal diffusion coefficient tester
- 6.3.2 pulsed laser source
- 6.3.3 Data acquisition and analysis means
- 6.3.4 Response temperature detector
- 6.3.5 Sample Base
- 6.3.6 Sample steady-state temperature measurement with a thermometer
- 6.3.7 Temperature control device
- 6.4 Sample
- 6.4.1 shape and size
- 6.4.2 Surface Treatment
- 6.4.3 Reference Sample
- 6.5 Test procedures and steps
- 6.5.1 Sample size measuring
- 6.5.2 Sample density measurements
- 6.5.3 Surface Treatment
- 6.5.5 sample temperature stability of
- 6.5.6 pulse heating energy
- 6.5.7 Temperature Measurement
- 6.5.8 Test data input
- 6.5.9 Test Record
- 6.6 Data Analysis
- 6.6.1 Calculation half the rise time of the principle of law
- 6.6.2 Semi-rise time range of 13 applicable law
- 6.7 Measurement Report
- Appendix A (informative) Thermal conductivity of copper hot electrode
- Annex B (informative) Principle of the laser flash method thermal diffusivity test
- Annex D (informative) Additional error factors
- References
1 Scope
This standard specifies the determination of beryllium oxide ceramic material thermal conductivity (thermal conductivity) of the club shaft and laser flashing method.
This standard specifies the method for measuring rod axis beryllium oxide ceramic temperature of the thermal conductivity in the range of 40 °C ~ 150 °C. This method can also
Suitable for measuring other low thermal conductivity ceramic material or a ceramic matrix composite material thermal conductivity within the above temperature range. Laser specified in this standard
Flash method is suitable for the thermal diffusivity and thermal conductivity measurements in the range from room temperature to 1400 °C porosity of less than 10% of beryllium oxide ceramic material rate. This method is also applicable in the above temperature range in the measurement of thermal diffusivity 10-7 m2/s ~ 10-3 m2/s between completely homogeneous , The energy pulse opaque other solid materials thermal diffusivity and thermal conductivity; suitable for measuring non-uniform or anisotropic material.
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein
Member. For undated references, the latest edition (including any amendments) applies to this document.
GB/T 2413-1980 piezoelectric ceramic material bulk density measurement method
GB/T 9530-1988 electronic ceramics Terminology
3 Terms and Definitions
GB/T 9530-1988 and defined the following terms and definitions apply to this document.
3.1 Thermal conductivity
Thermal Conductivity
Under steady-state thermal conditions, the density of heat flow rate divided by the temperature gradient. It means the unit area, the direction perpendicular to the plane of the unit temperature gradient
Steady-state rate of heat flow caused.
Note. The thermal conductivity of the material with temperature changes, and should therefore be given at the same time the average temperature measurement of thermal conductivity of the material.
3.2 Thermal diffusivity
Thermal diffusivity
Under non-steady state thermal conditions, the temperature of the physical parameters characterizing the ability to communicate. Thermal diffusivity is equal to thermal conductivity divided by the product of density and specific heat.
alpha =
Cprho (1)
Where.
alpha --- thermal diffusivity, in square meters per second (m2/s);
lambda --- thermal conductivity in watts per meter open [W/(m · K)];
CP --- specific heat units per kg of coke opening [J/(kg · K)];
p --- Density (rho = m/V, that is approximately the density p in the above temperature range to remain unchanged), in kilograms per cubic meter (kg/m3).
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB/T 5598
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 5598-2015 | Test method for thermal conductivity of beryllium oxide ceramics | current edition | Current |
| GB 5598-1985 | Test method for thermal conductivity of beryllium oxide ceramics | previous edition | Superseded |
This page sells the current edition, GB/T 5598-2015. Earlier editions are listed for reference only.
How to Download GB/T 5598-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 5598-2015
$455.00