Valid

GB/T 5475-2013Methods for sampling ion exchange resins (English PDF)

离子交换树脂取样方法

Open the GB/T 5475-2013 preview as PDF

Preview — first pages of GB/T 5475-2013 (full document: 15 pages)

This is a limited preview

Buy now to download the full PDF (15 pages)

Issued by

AQSIQ; SAC

Level / Type

National · Recommended

Issue date

September 6, 2013

Implementation date

January 31, 2014

Scope

GB/T 5475-2013 is the English-translated version of 离子交换树脂取样方法.

China's national method for sampling ion exchange resins. Ion exchange resin is supplied as millions of small polymer beads in a wet bed, and every property that is measured on it - capacity, moisture, particle size distribution, whole bead count - is measured on a sample of a few grams taken from a drum or a vessel holding hundreds of kilograms. Sampling is therefore the step that determines whether the analysis means anything, and a resin bed is unusually good at defeating careless sampling: the beads segregate by size as soon as the container is moved, the fines migrate to the top of a settled bed, and a sample scooped from the surface is systematically unrepresentative of what is below. The resin must also stay wet, since a bead that dries shrinks and cracks and is then counted as damaged. The standard specifies the method for sampling wet ion exchange resin and applies to wet resin sampling.

Document preview — GB/T 5475-2013

National Standard of the People's Republic of China

ICS
83.080.10
Classification
G 31

Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Instruments and devices
  • 2.1 Sampler
  • 3 Sampling Rules

Foreword

This standard is prepared in accordance with GB/T 1.1-2009 given rules. This standard replaces GB/T 5475-1985 "ion exchange resin sampling method", compared with the GB/T 5475-1985, the main technical change Of the following.

--- Amend the provisions of the sampling tool. The standard proposed by China Petroleum and Chemical Industry Association. This standard by the National Standardization Technical Committee plastic universal methods and products Club (SAC/TC15/SC4) centralized. This standard was drafted. Xi'an Thermal Power Research Institute Co., Ltd., Zibo East Chemical Co., Ltd., the National Quality Supervision, synthetic resin Inspection Center, Ningbo win glory Resin Co., Ltd., Jiangsu Su Qing water treatment engineering company. The main drafters. Zhang Peng Hua, Cuihuan Fang, Di Jinghua, Hu Jinjiang, Cai Xiaohua, Wangyong Gui. This standard replaces the standards previously issued as follows:

--- GB/T 5475-1985. Ion exchange resin sampling

1 Scope

China's national method for sampling ion exchange resins. Ion exchange resin is supplied as millions of small polymer beads in a wet bed, and every property that is measured on it - capacity, moisture, particle size distribution, whole bead count - is measured on a sample of a few grams taken from a drum or a vessel holding hundreds of kilograms. Sampling is therefore the step that determines whether the analysis means anything, and a resin bed is unusually good at defeating careless sampling: the beads segregate by size as soon as the container is moved, the fines migrate to the top of a settled bed, and a sample scooped from the surface is systematically unrepresentative of what is below. The resin must also stay wet, since a bead that dries shrinks and cracks and is then counted as damaged. The standard specifies the method for sampling wet ion exchange resin and applies to wet resin sampling.

2.2 points like container Flat enamel or plastic container.

2.3 sample container Clean sealable container.

2.1 Sampler

2.1.1 Material. stainless steel or plastic.

2.1.2 Size. inner diameter of 25mm ~ 30mm, opening width of 18mm ~ 20mm, the length of the opening is not less than the ion exchange resin storey 80% of degrees. As shown in Figure 1. The total length of the sampler can adjust the height of the exchange resin layer according to the container lon sampler probe into the bottom of the container opening paragraph After the trailing end of the surface layer is higher than the ion exchange resin is not less than 200mm.

Note. The sub-sampler can be made to facilitate different ion exchange resin layer height of specimen sampling. Millimeters Figure

3 Sampling Rules

3.1 Sampling We need resin samples from the same batch of ion exchange, when there are n the package, when n is less than or equal to

3.00 each sample shall not be less than 3; when n is greater than

3.00 to take a random sampling method, the total number of samples calculated according to the formula n 1 (whichever occurs decimals rounded up method Integer), each sample shall not be less than 2 times.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

How to Buy GB/T 5475-2013

  1. 1Add to cart. Click the "Buy GB/T 5475-2013" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 5475-2013

$50.00

$45.00for partners