Valid

GB/T 5456-2009Textiles -- Burning behaviour -- Flame spread properties of vertically oriented specimens (English PDF)

纺织品 燃烧性能 垂直方向试样火焰蔓延性能的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (9 pages)

Need quotation for your management?

Get a formal quotation for GB/T 5456-2009 in 30 minutes.

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Level / Type

National · Recommended

Issue date

September 30, 2009

Implementation date

February 1, 2010

Scope

GB/T 5456-2009 is the English-translated version of 纺织品 燃烧性能 垂直方向试样火焰蔓延性能的测定.

GB/T 5456-2009 — This standard specifies the test method for the flame spread time in the vertical direction of the textile. This standard applies to all kinds of single or multi-component (coating, quilting, multi-layer, sandwich products and similar combinations) of textile fabrics and industrial use Products.

Found what you need?

Document preview — GB/T 5456-2009

National Standard of the People's Republic of China

ICS
59.080.30; 13.220.40
Classification
W 04
Replacing
GB/T 5456-1997

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative reference documents
  • 3 Terms and definitions
  • 4 Principle
  • 5 Instruments
  • 5.1 Support frame

Foreword

This standard is modified using the international standard ISO 6941.:2003 "Textile fabric combustion performance Vertical direction sample flame spread performance Determination ".

This standard is redrafted according to ISO 6941.:2003 and the main differences with ISO 6941.:2003 are as follows.

--- normative reference documents in the international standard replaced by the corresponding national standards, an increase of the reference document GB/T 6529.

--- the air conditioning in Chapter 8 of the atmosphere from the "temperature 20 °C ± 2 °C, relative humidity 65% ± 5% humidity 24h" to "in GB/T 6529 under the standard atmospheric conditions for humidity control. " - Added "note" in Chapter 10.

This standard replaces GB/T 5456-1997 "Determination of Flame Propagation Performance in Vertical Direction Specimen of Textile Flammability", mainly the change is as follows.

- the scope of application of the standard is simplified as "all kinds of single or multi-component (coating, Yan, multi-layer, sandwich products and similar combinations) of the textile Fabric and industrial products ".

- GB/T 8746 and GB/T 3291.3 were added to the normative reference document.

- In Chapter 3, the words "continued burning", "continued burning time", "smoldering" and "smoldering time" were added, adding "ignition time".

- in the principle of the deletion of "can also observe, measure and record the sample of other flame spread performance." - Added support for the support frame in equipment and materials.

--- increase the gas igniter level or tilt the location of the ignition when the tip of the distance from the description of the sample.

--- Change the "sample holder" to "sample frame" and modify the specification.

--- Change the drilling description on the template to "Drill 12 holes with a diameter of about 4mm on the template".

--- ignition gas source increased "propane/butane mixture gas".

--- Change the mark line to "Line density 45tex to 50tex".

The size of the specimen is changed from (560 × 170) mm to (560 × 170) mm ± 2mm.

- the original standard in the three humidity conditions to a standard humidity control conditions, as "GB/T 6529 in the provisions of the standard atmospheric conditions Under the humidity control ".

--- Flame height adjustment mode from vertical adjustment to horizontal adjustment and vertical adjustment in two ways.

--- The provisions of the ignition time were modified.

- the recording of other burning properties of the fabric is canceled.

--- Added Chapter 11 "Precision".

Appendix A of this standard is a normative appendix, Appendix B is an informative appendix.

This standard is proposed by China Textile Industry Association.

This standard is under the jurisdiction of the National Standard Committee on Textile Standardization Technical Standards (SAC/TC209/SC1).

The drafting of this standard. Shanghai Entry-Exit Inspection and Quarantine Bureau, Textile Standardization Institute, Shanghai Aili Garment Inspection and Repair Co., Ltd.

1 Scope

This standard specifies the test method for the flame spread time in the vertical direction of the textile.

This standard applies to all kinds of single or multi-component (coating, quilting, multi-layer, sandwich products and similar combinations) of textile fabrics and industrial use Products.

2 Normative reference documents

The terms of the following documents are hereby incorporated by reference into this standard. Whichever is the date of the reference file, which is followed by all (Excluding corrigenda) or revisions do not apply to this standard, however, encourage the parties to reach an agreement under this standard Whether you can use the latest version of these files. For undated references, the latest edition applies to this standard.

Textiles - Properties and test terms for textile and textile materials - Part 3. General purpose GB/T GB/T 6529 Standard atmosphere for textiles for humidity control and testing (GB/T 6529-2008, ISO 139.:2005, MOD) GB/T 8746 Textiles - Combustion properties - Determination of easy ignitability in vertical direction (GB/T 8746-2009, ISO 6940.

2004, MOD)

3 Terms and definitions

GB/T 3291.3 and the following terms and definitions apply to this standard.

The time at which the flame of the ignition source is applied to the specimen.

The time required for the flame on the burning material to extend a certain distance or surface area, in seconds, under specified test conditions.

4 Principle

With the specified ignition of the flame, the vertical direction of the sample surface or the bottom edge of the ignition 10s. The flame was spread on the sample to three the time the mark line is used separately.

5 Instruments

5.1 Support frame

Should be able to maintain the specified relative position between the igniter (5.2, see Fig. 1) and the specimen frame (5.3, see Fig. 2) (see Fig. 3).

The instrument can be loaded with three markings on the position shown in Figure 2 (see 5.7). Install a ring at the location of each marker line both sides of the specimen to the front surface of 1mm and 5mm. A chronograph (5.6.2) is installed at each ring.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 9 pages — is available in the English PDF.

Referenced standards

How to Download GB/T 5456-2009

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
9 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 5456-2009