GB/T 4698.8-2017Methods for chemical analysis of titanium sponge, titanium and titanium alloys—Part 8: Determination of aluminum content—Separation with sodium hydroxide-EDTA complex-metric titration and inductively coupled plasma atomic emission spectrometry (English PDF)
海绵钛、钛及钛合金化学分析方法 第8部分:铝量的测定 碱分离-EDTA络合滴定法和电感耦合等离子体原子发射光谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 4698.8-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
September 29, 2017
Implementation date
April 1, 2018
Scope
GB/T 4698.8-2017 is the English-translated version of 海绵钛、钛及钛合金化学分析方法 第8部分:铝量的测定 碱分离-EDTA络合滴定法和电感耦合等离子体原子发射光谱法.
GB/T 4698.8-2017 is the Chinese standard "Methods for chemical analysis of titanium sponge, titanium and titanium alloys - Part 8: Determination of aluminum content - Separation with sodium hydroxide-EDTA complex-metric titration and inductively coupled plasma atomic emission spectrometry".
Its scope clause reads: This Part of GB/T 4698 specifies the methods to determine aluminum content in sponge titanium, titanium and titanium alloys. This Part is applicable to the determination of aluminum content in sponge titanium, titanium and titanium alloys.
The determination range: 0.80%~8.50% for Method One; 0.010%~8.50% for Method Two. When the determination ranges overlap, Method One is the arbitration analysis method.
Its clauses include test report; method one - alkali separation - edta. It was issued by the General Administration of Quality Supervision, Inspection and Quarantine on SEPTEMBER 29, 2017 and took effect on APRIL 01, 2018.
Found what you need?
Document preview — GB/T 4698.8-2017
National Standard of the People's Republic of China
- ICS
- 77.120.50
- Classification
- H 14
- Replacing
- GB/T 4698.8-1996
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope6
- 2 Method One - Alkali separation - EDTA complexometric titration6
- 3 Method Two -- Inductively coupled plasma atomic emission spectrometry11
- 4 Test report14
1 Scope
This Part of GB/T 4698 specifies the methods to determine aluminum content in sponge titanium, titanium and titanium alloys.
This Part is applicable to the determination of aluminum content in sponge titanium, titanium and titanium alloys. The determination range: 0.80%~8.50% for Method One; 0.010%~8.50% for Method Two. When the determination ranges overlap, Method One is the arbitration analysis method.
2 Method One - Alkali separation -
EDTA complexometric titration
2.1 Method summary
The test material is dissolved with sulfuric acid. Separate the elements such as titanium, iron, chromium, zirconium, copper, manganese and part of vanadium by sodium hydroxide precipitation. In a weakly acidic medium of pH5, add EDTA complex aluminum. Use zinc acetate standard titration solution to titrate excessive EDTA. Add potassium fluoride to complex aluminum and release quantitative EDTA. Then use zinc acetate standard titration solution to titrate EDTA released, so as to obtain the aluminum content.
For tin interference determination, add potassium iodide to volatilize to remove.
Vanadium affects the judgment of the end point of titration. Add hydroxylamine hydrochloride to eliminate its interference.
2.2 Reagents
Unless otherwise stated, only the confirmed analytically-pure reagents and laboratory grade two water are used in the analysis.
2.2.1 Nitric acid (rho=1.42g/mL).
2.2.2 Sulfuric acid (1+1).
2.2.3 Hydrochloric acid (1+1).
2.2.4 Potassium iodide solution (200g/L).
2.2.5 Ferric chloride solution (50g/L): Weigh 5g of iron trichloride (FeCl3·6H2O) and dissolve it in 100mL of hydrochloric acid (1+99).
2.2.6 Sodium hydroxide solution (300g/L).
2.2.7 Sodium hydroxide solution (150g/L).
2.2.8 Copper chloride solution (10g/L): Weigh 1g of copper chloride (CuCl2·2H2O) and dissolve it in 100mL of water.
2.2.9 Hydroxylamine hydrochloride solution (100g/L).
2.2.10 Disodium ethylenediaminetetraacetic acid (Na2EDTA) solution
[c(Na2EDTA)]=0.05mol/L]: Weigh 18.6g of Na2EDTA (C10H14N2O8Na2·2H2O) into a 500mL beaker. Add 300mL of water to dissolve. Transfer to a 1000mL volumetric flask. Use water to dilute to the scale mark. Mix well.
2.2.11 Hexamethylenetetramine buffer solution (pH5): Weigh 150g of hexamethylenetetramine in a 1000mL beaker. Add 400mL of water to dissolve. Add about 50mL of hydrochloric acid (rho=1.19g/mL) to adjust the solution to about pH 5 (check with pH test paper). Use water to dilute to 500mL. Mix well.
2.2.12 Potassium fluoride solution (200g/L): Stored in plastic bottles.
2.2.13 Aluminum standard storage solution
Weigh 1.0000g of metallic aluminum (wAl>=99.99%) into a 300mL beaker. Add 20mL of sodium hydroxide solution (2.2.6). After the violent reaction stops, heat to dissolve. Remove it and cool. Add hydrochloric acid (2.2.3) until the precipitated precipitate is dissolved with an excess of 20mL. Cool. Transfer to a 1000mL volumetric flask. Use water to dilute to the scale mark. Mix well. 1mL of this solution contains 1.0mg of aluminum.
2.2.14 Standard titration solution of zinc acetate [c(Zn2+)~0.014mol/L]
2.2.14.1 Preparation: Weigh 3g of zinc acetate [Zn(CH3COO)2·2H2O] into a 200mL beaker. Add 50mL of water to dissolve. Add 2mL of glacial acetic acid (rho=1.05g/mL). Transfer to a 1000mL volumetric flask. Use water to dilute to the scale mark. Mix well.
2.2.14.2 Calibration: Pipette three portions of 5.00mL of aluminum standard
3 Method Two -- Inductively coupled plasma atomic emission spectrometry
3.2.3 Nitric acid (rho=1.42g/mL)
3.2.4 Titanium (wTi>=99.9%, wAl< 0.005%)
3.2.5 Aluminum standard storage solution: Weigh 1.0000g of metallic aluminum
(wAi>=99.99%) into a 300mL beaker. Add 20mL of sodium hydroxide solution (300g/L). After the violent reaction stops, heat to dissolve. Remove and cool.
Add hydrochloric acid (3.2.1) until the precipitated precipitate is dissolved with an excess of 20mL. Cool. Transfer to a 1000mL volumetric flask. Use water to dilute to the scale mark. Mix well. 1mL of this solution contains 1mg of aluminum.
3.2.6 Aluminum standard solution A: Pipette 10.00mL of aluminum standard
stock solution (3.2.5) into a 100mL volumetric flask. Add 5mL of hydrochloric acid (3.2.1). Use water to dilute to the scale mark. Mix well. 1mL of this solution contains 100µg of aluminum.
3.2.7 Aluminum standard solution B: Pipette 10.00mL of aluminum standard
solution A (3.2.6) into a 100mL volumetric flask. Add 5mL of hydrochloric acid (3.2.1). Use water to dilute to the scale mark. Mix well. 1mL of this solution contains 10µg of aluminum.
3.2.8 Argon (volume fraction>=99.99%)
3.3 Instruments
Inductively coupled plasma atomic emission spectrometer: Equipped with hydrofluoric acid resistant sampling system, of which the resolution is less than 0.006nm (at 200nm).
3.4 Specimen
Follow the promulgated standards for sample preparation of sponge titanium, titanium and titanium alloys.
3.5 Analysis steps
3.5.1 Test material
Weigh 0.10g of specimen (3.4), to the nearest of 0.0001g.
3.5.2 Number of determinations
Conduct two determinations independently. Take the average value.
3.5.3 Blank test
Conduct the blank test with test material.
3.5.4 Preparation of analytical test solution
3.5.4.1 Place the test material (3.5.1) in a 100mL PTFE beaker. Blow in a small amount of water. Add 5mL of hydrochloric acid (3.2.1). Add 1mL of hydrofluoric acid (3.2.2). Heat at low temperature until the sample is completely dissolved.
Then add 0.5mL of nitric acid (3.2.3) dropwise until the solution is clear.
Continue heating to drive off nitrogen oxides. Remove and cool to room temperature.
3.5.4.2 Transfer to a 100mL plastic volumetric flask. Use water to dilute to the scale mark. Mix well.
3.5.5 Preparation of working curve solution
3.5.5.1 Weigh 6 portions of titanium metal (3.2.4) equivalent to the titanium content of the test material (3.5.1) in a series of 100mL PTFE beakers. Operate according to 3.5.4.1 along with the test material.
3.5.5.2 Transfer the solution to six 100mL plastic volumetric flasks. Add 0mL, 1.00mL of aluminum standard solution B (3.2.7), 1.00mL of aluminum standard solution A (3.2.6), 1.00mL, 3.00mL, 6.00mL, 9.00mL of aluminum standard storage solution (3.2.5) in sequence. Use water to dilute to the scale mark. Mix well.
3.5.6 Measurement
In the inductively coupled plasma atomic emission spectrometer, at the selected wavelength (the spectrum line is not specifically specified; the recommended analysis line wavelength of aluminum is 237.312nm, 394.401nm, and the interference of the spectrum line shall be checked when using it), determine the working curve solution (3.5.5.2). When the working curve is linear r>=0.999, conduct the determination of analysis test solution (3.5.4.2). Check the background of the element spectrum and correct it at the appropriate position.
The mass concentration of aluminum element is automatically given by the computer.
3.6 Calculation of analysis results
The amount of aluminum is calculated as the mass fraction of aluminum wAl, calculated according to formula (3):
Where, rho 1 - The mass concentration of aluminum in the measured solution obtained from the working curve, in micrograms per milliliter (µg/mL); […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB/T 4698.8
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 4698.8-2017 | Methods for chemical analysis of titanium sponge, titanium and titanium alloys—Part 8: Determination of aluminum content—Separation with sodium hydroxide-EDTA complex-metric titration and inductively coupled plasma atomic emission spectrometry | current edition | Current |
| GB/T 4698.8-1996 | Methods for chemical analysis of titanium sponge, titanium and titanium alloys—Part 8: Determination of aluminum content—Separation with sodium hydroxide-EDTA complex-metric titration and inductively coupled plasma atomic emission spectrometry | previous edition | Superseded |
This page sells the current edition, GB/T 4698.8-2017. Earlier editions are listed for reference only.
How to Download GB/T 4698.8-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 4698.9-2017 — Methods for chemical analysis of titanium sponge,titanium and titanium alloys - Part 9: Determination of tin content - Potassium iodate titration and inductively coupled plasma atomic emission spectrometry
GB/T 4698.7-2011 — Methods for chemical analysis of titanium sponge,titanium and titanium alloys - Determination of oxygen and nitrogen content
GB/T 4698.10-2020 — Methods for chemical analysis of titanium sponge, titanium and titanium alloys - Part 10: Determination of chromium content - Ammonium ferrous sulfate titration and inductively coupled plasma atomic emission spectrometry (with vanadium)
Secure payment via Stripe
Payments accepted
GB/T 4698.8-2017
$145.00