GB/T 4698.10-2020Methods for chemical analysis of titanium sponge, titanium and titanium alloys - Part 10: Determination of chromium content - Ammonium ferrous sulfate titration and inductively coupled plasma atomic emission spectrometry (with vanadium) (English PDF)
海绵钛、钛及钛合金化学分析方法 第10部分:铬量的测定 硫酸亚铁铵滴定法和电感耦合等离子体原子发射光谱法(含钒)
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 4698.10-2020 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 6, 2020
Implementation date
February 1, 2021
Scope
GB/T 4698.10-2020 is the English-translated version of 海绵钛、钛及钛合金化学分析方法 第10部分:铬量的测定 硫酸亚铁铵滴定法和电感耦合等离子体原子发射光谱法(含钒).
GB/T 4698.10-2020 is the Chinese standard "Methods for chemical analysis of titanium sponge, titanium and titanium alloys - Part 10: Determination of chromium content - Ammonium ferrous sulfate titration and inductively coupled plasma atomic emission spectrometry (with vanadium)".
Its scope clause reads: This part of GB/T 4698 specifies the method for determining the amount of chromium (including vanadium) in sponge titanium, titanium and titanium alloys.
This section applies to the determination of chromium in sponge titanium, titanium and titanium alloys (the main component of titanium alloys contains vanadium).
Method one measurement range Circumference. 0.30%~15.00%; Method 2 measurement range. 0.010%~15.00%. When the scope of determination overlaps, method one in this section is arbitration method.
Its clauses include method-ferrous ammonium sulfate titration method; test report.
Found what you need?
Document preview — GB/T 4698.10-2020
National Standard of the People's Republic of China
- ICS
- 77.120.50
- Classification
- H 14
- Replacing
- GB/T 4698.10-1996
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Method-Ferrous ammonium sulfate titration method
- 3 Method two inductively coupled plasma atomic emission spectrometry
- 4 Test report
1 Scope
This part of GB/T 4698 specifies the method for determining the amount of chromium (including vanadium) in sponge titanium, titanium and titanium alloys.
This section applies to the determination of chromium in sponge titanium, titanium and titanium alloys (the main component of titanium alloys contains vanadium). Method one measurement range
Circumference. 0.30%~15.00%; Method 2 measurement range. 0.010%~15.00%. When the scope of determination overlaps, method one in this section is arbitration method.
2 Method-Ferrous ammonium sulfate titration method
2.1 Principle
The sample is dissolved in sulfuric acid, and in a sulfuric acid medium at room temperature, the vanadium is oxidized to a high price with potassium permanganate, and the standard drop of ferrous ammonium sulfate is used.
Titrate vanadium with a constant solution.
Under heating conditions, using silver nitrate as a catalyst, ammonium persulfate is used to simultaneously oxidize vanadium and chromium to high prices, and then use ferrous ammonium sulfate standard
The titration solution titrates vanadium and chromium.
The difference between the volume of the titrant consumed in the two titrations is the volume of the titrant required for the titration of chromium, from which the amount of chromium is obtained.
2.2 Reagents
Unless otherwise stated, only reagents and laboratory secondary water confirmed to be analytically pure are used in the analysis.
2.2.1
Nitric acid (rho=1.42g/L).
2.2.2
Sulfuric acid (1 1).
2.2.3
Potassium permanganate solution (5g/L).
2.2.4
Urea solution (100g/L).
2.2.5
Sodium nitrite solution (10g/L).
2.2.6
Silver nitrate solution (10g/L).
2.2.7
Ammonium persulfate solution (250g/L), prepared immediately after use.
2.2.8
Sodium chloride solution (100g/L).
2.2.9 Chromium standard solution
weigh 2.8290g of potassium dichromate (reference reagent) dried at 105°C for 1h and cooled to room temperature in 500mL
In the beaker, add about 100mL of water to dissolve it, transfer to a 1000mL volumetric flask, dilute to the mark with water, and mix. This solution 1mL contains
1.0mg chromium.
2.2.10
Preparation of ferrous ammonium sulfate standard titration solution [c(Fe2)~0.025mol/L]. Weigh 10.0g ferrous ammonium sulfate [Fe(SO4)· (NH4)2SO4·6H2O] was placed in a 500mL beaker, and.200mL sulfuric acid (2.2.2) was added to dissolve it. Transfer into 1000mL capacity
In the bottle, dilute to the mark with water and mix well.
2.2.11
Calibration of ferrous ammonium sulfate standard titration solution. Pipette three 10.00mL chromium standard solutions (2.2.9) into three 500mL cones.
In the flask, add 25mL sulfuric acid (2.2.2), 2 drops of manganese sulfate solution (50g/L), and perform the other operations according to 2.4.4.5~2.4.4.7.parallel
The volume range of the standard titration solution (2.2.10) of ferrous ammonium sulfate consumed for calibration should be no more than 0.10mL, whichever is the average value. According to formula (1)
Calculate the actual concentration of the ferrous ammonium sulfate titration solution (2.2.10).
2.2.12 N-phenylanthranilic acid solution (2g/L). Weigh 0.2g of N-phenylanthranilic acid and dissolve in 100mL sodium carbonate solution.
Solution (2g/L).
2.3 Sample
Follow the published sampling standards for titanium sponge, titanium and titanium alloys.
2.4 Test procedure
2.4.1 Sample
Weigh the sample (2.3) according to Table 1, accurate to 0.0001g.
2.4.2 Parallel test
Do two tests in parallel and take the average value.
2.4.3 Blank test
Do a blank test with the sample.
2.4.4 Determination
2.4.4.1
Place the sample (2.4.1) in a 500mL conical flask, add 25mL sulfuric acid (2.2.2), heat to dissolve the sample, and add nitric acid dropwise (2.2.1) To the solution purple disappears, heat to remove nitrogen oxides, and cool.
2.4.4.2
Dilute with water to about 100mL, add potassium permanganate solution (2.2.3) dropwise until the solution is stable red, and leave it for 3min.
2.4.4.3
Add 10mL urea solution (2.2.4), add sodium nitrite solution (2.2.5) dropwise under shaking until the red color of the solution disappears, and place
2min.
2.4.4.4
Add 5 drops of N-phenylanthranilic acid solution (2.2.12) and titrate to solution with ferrous ammonium sulfate standard titration solution (2.2.10)
The end point is the change from pink to yellow-green.
2.4.4.5
Dilute the solution (2.4.4.4) with water to.200mL, add 5mL silver nitrate solution (2.2.6), 10mL ammonium persulfate solution (2.2.7), heat the solution until the red color of permanganic acid appears, and boil until big bubbles appear.
2.4.4.6
Remove, add 5mL sodium chloride solution (2.2.8), heat and boil until the solution red disappears, remove, cool to room temperature with running water.
2.4.4.7
Add 10mL sulfuric acid (2.2.2), 5 drops of N-phenylanthranilic acid solution (2.2.12), and use ferrous ammonium sulfate standard titration solution (2.2.10) Titration until the solution changes from pink to yellow-green is the end point.
2.5 Test data processing
2.6 Precision
2.6.1 Repeatability
The measured values of two independent test results obtained under repeatability conditions are within the average range given in Table 2.These two test results
The absolute difference does not exceed the repeatability limit (r), and the case of exceeding the repeatability limit (r) does not exceed 5%. Repeatability limit (r) adopts the line according to the data in Table 2
Obtained by sexual interpolation or extension method.
2.6.2 Reproducibility
The measured values of two independent test results obtained under reproducibility conditions are within the range of the average value given in Table 3.
The absolute difference does not exceed the reproducibility limit (R), and does not exceed 5% in the case of exceeding the reproducibility limit (R). Reproducibility limit (R) is adopted according to the data in Table 3
Obtained by linear interpolation or extension method.
3 Method two inductively coupled plasma atomic emission spectrometry
3.1 Principle
Dissolve the sample with hydrochloric acid and hydrofluoric acid, and add titanium oxide nitrate dropwise. Use inductively coupled plasma atomic emission spectrometry to determine
Calculate the mass concentration of chromium by curve method, and express the measurement result by mass fraction.
3.2 Reagents
Unless otherwise stated, only reagents and laboratory secondary water confirmed to be analytically pure are used in the analysis.
3.2.1
Hydrochloric acid (rho=1.18g/mL).
3.2.2
Hydrofluoric acid (rho=1.15g/mL).
3.2.3
Nitric acid (rho=1.42g/mL).
3.2.4 Chromium standard storage solution
weigh 2.8290g of potassium dichromate (reference reagent) dried at 105°C for 1h and cooled to room temperature in 500mL
In the beaker, add about 100mL of water to dissolve it, transfer to a 1000mL volumetric flask, dilute to the mark with water, and mix. This solution 1mL contains
1.0mg chromium.
3.2.5
Chromium standard solution A. Pipette 10.00mL chromium standard stock solution (3.2.4) into a 100mL volumetric flask, add 5mL hydrochloric acid (3.2.1), dilute to the mark with water, and mix well. This solution 1mL contains 100µg chromium.
3.2.6 Chromium standard solution B
Pipette 10.00mL chromium standard solution A (3.2.5) into a 100mL volumetric flask, add 5mL hydrochloric acid (3.2.1), dilute to the mark with water, and mix well. This solution 1mL contains 10µg chromium.
3.2.7
Titanium (wTi>=99.95%, wCr< 0.001%).
3.2.8
Argon (volume fraction >=99.99%).
3.3 Apparatus
3.3.1 Inductively coupled plasma atomic emission spectrometer
equipped with a hydrofluoric acid resistant sampling system, with a resolution of less than 0.006nm (at.200nm).
3.3.2
The recommended wavelength of the chromium element analysis line is 283.56nm.
3.4 Sample
Follow the published sampling standards for titanium sponge, titanium and titanium alloys.
3.5 Test procedure
3.5.1 Sample
Weigh 0.10g sample (3.4), accurate to 0.0001g.
3.5.2 Parallel test
Do two tests in parallel and take the average value.
3.5.3 Blank test
Do a blank test with the sample.
3.5.4 Preparation of test solution
3.5.4.1 Preparation of analysis test solution
Place the sample (3.5.1) in a polytetrafluoroethylene beaker, blow in a small amount of water, add 5 mL of hydrochloric acid (3.2.1), and add 1 mL of hydrofluoric acid (3.2.2), heat at low temperature until the sample is completely dissolved, then add 0.5mL nitric acid (3.2.3) dropwise until the solution is clear. Remove and cool to room temperature,
Transfer to a 100mL plastic volumetric flask, dilute to the mark with water, and mix.
For samples containing chromium >= 8%, it is necessary to separate them for determination. Pipette 10.00mL of the above test solution into a 100mL volumetric flask, add 2mL of salt
Acid (3.2.1), dilute to the mark with water, and mix well.
3.5.4.2 Preparation of standard series solutions
Curve 1 (the mass fraction of chromium is 0.010%~8.00%). Weigh 7 parts of titanium metal (3.2.7) equivalent to the titanium content of the sample (3.5.1)
In a series of 100mL PTFE beakers, dissolve the sample according to 3.5.4.1 along with the sample. After the solution is cooled, transfer 7 100mL plastic
Material in a volumetric flask. Add 0mL, 1.00mL chromium standard solution B (3.2.6), 1.00mL chromium standard solution A (3.2.5), 1.00mL,
2.00mL, 4.00mL, 8.00mL chromium standard stock solution (3.2.4), dilute to the mark with water, and mix.
Curve 2 (the mass fraction of chromium is 8.00%~15.00%). Weigh the metal titanium (3.2.7) with the titanium content of the sample (3.5.1) into one
In a 100mL polytetrafluoroethylene beaker, dissolve, cool and dilute with the sample according to 3.5.4.1.Divide 10.00mL test solution into 6
100mL plastic volumetric flask. Add 0mL, 3.00mL, 6.00mL, 9.00mL chromium standard solution A (3.2.5), 1.20mL,
1.60mL chromium standard stock solution (3.2.4), dilute to the mark with water, and mix.
3.6 Determination
Measure the working curve solution on the inductively coupled plasma emission spectrometer at the recommended wavelength, when the linear correlation coefficient of the working curve
When k>=0.999, measure the emission intensity of the test element in the analysis test solution (3.5.4.1) and the accompanying sample blank solution (3.5.3), from the working curve
Check the mass concentration of chromium.
3.7 Test data processing
The amount of chromium is calculated by the mass fraction wCr of chromium, calculated according to formula (3).
When the result is less than or equal to 0.10%, two significant digits are reserved; when the result is greater than 0.10%, it is reserved to two decimal places.
3.8 Precision
3.8.1 Repeatability
The measured values of two independent test results obtained under repeatability conditions are within the average range given in Table 4, and the two test results
The absolute difference does not exceed the repeatability limit (r), and the repeatability limit (r) does not exceed 5%. The repeatability limit (r) is based on the data in Table 4.
Obtained by sexual interpolation or extension method.
3.8.2 Reproducibility
The measured values of two independent test results obtained under reproducibility conditions are within the range of the average value given in Table 5.
The absolute difference does not exceed the reproducibility limit (R), and the reproducibility limit (R) does not exceed 5%. The reproducibility limit (R) is based on the data in Table 5.
Obtained by sexual interpolation or extension method.
4 Test report
The test report should include the following.
---Test object;
--- Standards used (including release and publication year number);
---Method used;
---result;
--- Anomalies observed;
---Test date.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
Editions of GB/T 4698.10
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 4698.10-2020 | Methods for chemical analysis of titanium sponge, titanium and titanium alloys - Part 10: Determination of chromium content - Ammonium ferrous sulfate titration and inductively coupled plasma atomic emission spectrometry (with vanadium) | current edition | Current |
| GB/T 4698.10-1996 | Methods for chemical analysis of titanium sponge, titanium and titanium alloys - Part 10: Determination of chromium content - Ammonium ferrous sulfate titration and inductively coupled plasma atomic emission spectrometry (with vanadium) | previous edition | Superseded |
This page sells the current edition, GB/T 4698.10-2020. Earlier editions are listed for reference only.
How to Download GB/T 4698.10-2020
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 4698.1-2017 — Methods for chemical analysis of titanium sponge, titanium and titanium alloys - Part 1: Determination of copper content - Flame atomic absorption spectrometry
GB/T 4698.11-1996 — Sponge titanium,titanium and titanium alloys--Determination of chromium content in the absence of Vanadium--Ammonium ferrous sulfate titration method
GB/T 4698.12-2017 — Methods for chemical analysis of titanium sponge, titanium and titanium alloys - Part 12: Determination of vanadium content - Ammonium ferrous sulfate titration and inductively coupled plasma atomic emission spectrometry
Secure payment via Stripe
Payments accepted
GB/T 4698.10-2020
$145.00