GB/T 4324.18-2012Methods for chemical analysis of tungsten - Part 18: Determination of potassium content - Flame atomic absorption spectrometry (English PDF)
钨化学分析方法 第18部分:钾量的测定 火焰原子吸收光谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 4324.18-2012 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 31, 2012
Implementation date
October 1, 2013
Scope
GB/T 4324.18-2012 is the English-translated version of 钨化学分析方法 第18部分:钾量的测定 火焰原子吸收光谱法.
GB/T 4324.18-2012 is the Chinese standard "Methods for chemical analysis of tungsten - Part 18: Determination of potassium content - Flame atomic absorption spectrometry".
Its scope clause reads: This section GB/T 4324 provisions of the tungsten powder, tungsten, tungsten carbide, tungsten trioxide, tungsten blue, purple tungsten, tungsten acid, ammonium paratungstate, ammonium metatungstate Determination of the amount of potassium.
This Part applies to tungsten powder, tungsten, tungsten carbide, tungsten trioxide, tungsten blue, purple tungsten, tungsten acid, ammonium paratungstate, ammonium metatungstate measured amount of potassium.
Determination range of 0.0005% to 0.080%. Its clauses include method summary; reagents; instrument.
Found what you need?
Document preview — GB/T 4324.18-2012
National Standard of the People's Republic of China
- ICS
- 77.120.99
- Classification
- H 63
- Replacing
- GB/T 4324.18-1984
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Method summary
- 3 Reagents
- 4 Instrument
1 Scope
This section GB/T 4324 provisions of the tungsten powder, tungsten, tungsten carbide, tungsten trioxide, tungsten blue, purple tungsten, tungsten acid, ammonium paratungstate, ammonium metatungstate
Determination of the amount of potassium.
This Part applies to tungsten powder, tungsten, tungsten carbide, tungsten trioxide, tungsten blue, purple tungsten, tungsten acid, ammonium paratungstate, ammonium metatungstate measured amount of potassium.
Determination range of 0.0005% to 0.080%.
2 Method summary
Tungsten powder, tungsten, tungsten carbide, tungsten blue, purple tungsten with hydrogen peroxide and ammonia decomposition; tungsten trioxide, tungstic acid, ammonium paratungstate, ammonium metatungstate with ammonia break down. Cesium chloride as deionization agent, atomic absorption spectrometer, potassium measured absorbance at a selected optimum working conditions.
3 Reagents
Unless otherwise indicated, the reagents used are standard in line with national standards or industry standard analytical reagent, the water should meet the resistivity
>=18Mohm · cm.
3.1
Ammonia (rho = 0.88g/mL), pure class distinctions.
3.2
Hydrogen peroxide (rho = 1.10g/mL), pure class distinctions.
3.3
cesium chloride solution (20g/L).
3.4 Potassium standard stock solution
Weigh 0.1907g advance by burning 550 °C 1h potassium chloride (wKCl>=99.9%), placed in a quartz beaker
In, dissolved in water and transferred to 1000mL volumetric flask, dilute with water to volume, and mix. Stored in a plastic bottle, the solution containing 1mL
100µg potassium.
3.5 Potassium standard solution
Pipette 25.00mL potassium standard stock solution (3.4), placed in 500mL volumetric flask, dilute to the mark with water, mix uniform. Stored in a plastic bottle, 1mL solution containing 5µg potassium.
3.6 tungsten matrix
the composition of the sample is similar to the potassium content of not more than 0.0005%.
4 Instrument
4.1
Atomic absorption spectrometer, with a potassium hollow cathode lamp.
Under optimum working conditions for those who can reach the following indicators can be used.
--- Characteristic concentration. in the solution was measured and consistent substrate solution, wherein the concentration of potassium is not more than 0.01µg/mL.
--- Precision. standard solution with the highest concentration of 10 times the absorbance measurements, the standard deviation should not exceed 1.5% of the average absorbance;
The lowest concentration of standard solution used (instead of "zero concentration" standard solution) absorbance measured 10 times, and the standard deviation should not exceed the maximum
0.5% concentration of the standard average absorbance.
--- Linear curve. the curve according to concentration, is divided into five sections, the difference between the absorbance of the absorbance difference between the highest and the lowest segment of the segment
Ratio of not less than 0.7.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
Editions of GB/T 4324.18
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 4324.18-2012 | Methods for chemical analysis of tungsten - Part 18: Determination of potassium content - Flame atomic absorption spectrometry | current edition | Current |
| GB/T 4324.18-1984 | Methods for chemical analysis of tungsten - Part 18: Determination of potassium content - Flame atomic absorption spectrometry | previous edition | Superseded |
This page sells the current edition, GB/T 4324.18-2012. Earlier editions are listed for reference only.
How to Download GB/T 4324.18-2012
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 4324.1-2012 — Methods for chemical analysis of tungsten - Part 1: Determination of lead content - Flame atomic absorption spectrometry
GB/T 4324.10-2012 — Methods for chemical analysis of tungsten - Part 10: Determination of copper content - Flame atomic absorption spectrometry
GB/T 4324.11-2012 — Methods for chemical analysis of tungsten - Part 11: Determination of aluminum content - Inductively coupled plasma atomic emission spectrometry
Secure payment via Stripe
Payments accepted
GB/T 4324.18-2012