GB/T 41013-2021Evaluation of energy performance of motor system (English PDF)
电机系统能效评价
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 41013-2021 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 31, 2021
Implementation date
July 1, 2022
Scope
GB/T 41013-2021 is the English-translated version of 电机系统能效评价.
GB/T 41013-2021 sets out how to evaluate the energy performance of a motor system and give it an energy efficiency level.
It covers stable-running systems made up of small and medium-sized electric motors below 1000 kW, a single driven machine - fan, pump or air compressor - and its control device, transmission and pipe network; more complex systems and motor system stations can use it as a reference.
The standard defines the efficiency levels and the procedure, from the documents collected to the scoring carried out against the index system and scoring method of normative Annex A, where any item without supporting evidence scores zero, and it lists what the evaluation report must contain, including energy-saving recommendations.
It is intended for system operators and evaluation bodies. It was issued on 31 December 2021 and has applied since 1 July 2022.
Found what you need?
Document preview — GB/T 41013-2021
National Standard of the People's Republic of China
- ICS
- 27.010
- Classification
- F 01
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Terms and definitions6
- 4 Energy efficiency level6
- 5 Evaluation procedures6
- Annex A (normative) Comprehensive scoring index system and scoring method for energy efficiency of motor system9
- Bibliography17
1 Scope
This Standard specifies evaluation levels, evaluation procedures for energy performance of motor system.
This Standard is applicable to evaluation of the energy efficiency of the stable running motor system (hereinafter referred to as the system) composed of small and medium-sized electric motors (below 1000kW), single driving equipment (fan, pump, air compressor) and its control device, transmission device and pipe network. Other complex motor systems, motor system stations can use this document as reference.
2 Normative references
The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
GB/T 12497, Three-phase induction motors economic operation
GB/T 13466, The general principles of economic operation for AC driven fan (pump air compressor) system
GB/T 13469, Economical operation for centrifugal, mixed flow and axial flow pump systems
GB/T 13470, Economical operation for the fan system
GB/T 15913, Monitoring and testing for energy saving of fan's unit and distribute tube system
GB/T 16665, Monitoring and testing for energy saving of air compressor unit and air distribution system
GB/T 16666, Monitoring and testing for energy saving of motor-pump liquid transport system
GB 17167, General principle for equipping and managing of the measuring instrument of energy in organization of energy using
GB 18613, Minimum allowable values of energy efficiency and values of efficiency grades for motors
GB 19153, Minimum allowable values of energy efficiency and energy efficiency grades for displacement air compressors
GB 19761, Minimum allowable values of energy efficiency and energy efficiency grades for fan
GB 19762, The minimum allowable values of energy efficiency and evaluating values of energy conservation of centrifugal pump for fresh water
GB/T 21056, Specification for adjustable speed drive systems of electricity conservation with VF for fans and pumps
GB/T 26921, The guide of design optimization for motor systems (fans, pumps, air compressors)
GB/T 27883, Economical operation for displacement air compressor system
GB 28381, Minimum allowable values of energy efficiency and evaluating values of energy conservation for centrifugal blower
GB/T 29314, Specification for the Reconstruction of Motor System for Energy-saving
GB 30253, Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for Permanent Magnet Synchronous Motors
GB 30254, Minimum Allowable Values of Energy Efficiency and the Energy Efficiency Grades for Cage Three-phase High Voltage Induction Motor
GB/T 30256, Technical Requirements of Measurement and Verification of Energy Savings, Pumped Liquid Delivery System
GB/T 30257, Technical Requirements of Measurement and Verification of Energy Savings, Fan System
GB 32029, Minimum allowable values of energy efficiency and energy efficiency grades for small-size submersible motor-pumps
GB 32030, Minimum allowable values of energy efficiency and energy efficiency grades for submersible pumps for deep well
GB 32031, Minimum allowable values of energy efficiency and energy efficiency grades for waste submersible motor-pumps
GB 32284, Minimum allowable values of energy efficiency and energy efficiency grades for petrochemical centrifugal pumps
5 Evaluation procedures
5.4 Evaluation implementation
5.4.1 The operator or management party of the motor system shall ensure that the operation of the system complies with the requirements of laws, regulations and mandatory standards such as safety, energy saving and environmental protection.
5.4.2 The evaluation agency or personnel shall evaluate the energy efficiency of the motor system according to the scoring index system and scoring method given in Annex A and give quantitative results.
5.4.3 The evaluation agency or personnel shall give scores by consulting and checking design documents, statistical reports, original records, declaration documents, analysis/test reports, relevant third-party certification certificates and other supporting materials. Relevant evaluation information can also be collected through discussions, field investigations, sample surveys, and field tests. Each scoring result shall be supported by documented information. The score for the scoring item without corroborating materials is 0.
5.4.4 The evaluation agency or personnel can give suggestions on energy-saving measures in terms of system optimization and transformation, strengthening management based on the scoring results.
5.5 Preparation of evaluation report
The content of the evaluation report shall include:
a) A brief description of the evaluation work process;
b) Evaluation of the implementation team;
c) Scope of evaluation;
d) Evaluation of the list of information collected;
e) Description of the score sheet and the certified materials;
f) Energy efficiency rating and comprehensive score;
g) Recommendations for energy saving measures; […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 12497Three-phase induction motor's economic operation
- GB/T 13466The general principles of economic operation for AC driven fan (pump, air compressor) system
- GB/T 13469Economical operation for centrifugal, mixed flow and axial flow pump systems
- GB/T 13470Economical operation for the fan system
- GB/T 15913Monitoring and testing for energy saving of fan's unit and distribute tube system
- GB/T 16665Monitoring and testing for energy saving of air compressor unit and air distribution system
GB/T 30257
Similar standards
How to Download GB/T 41013-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 17167-2025 — General rules for energy measuring instrument equipping and managing of energy user
GB 18613-2020 — Minimum allowable values of energy efficiency and values of efficiency grades for motors
GB 19153-2019 — Minimum allowable values of energy efficiency and energy efficiency grades for displacement air compressors
Secure payment via Stripe
Payments accepted
GB/T 41013-2021