Valid

GB/T 40688-2021Internet of things—Data interface of vital signs sensing devices (English PDF)

物联网 生命体征感知设备数据接口

Preview PDF

This is a limited preview

Buy now to download the full PDF (36 pages)

Need quotation for your management?

Get a formal quotation for GB/T 40688-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

October 11, 2021

Implementation date

May 1, 2022

Scope

GB/T 40688-2021 is the English-translated version of 物联网 生命体征感知设备数据接口.

GB/T 40688-2021 specifies the data interface between vital signs sensing devices and vital signs monitoring systems in Internet of Things applications.

It sets general rules on the communication protocol, interface description, coded character set and data types, the formats of request and response messages, and the basic functions and parameters of the general interfaces, both request-type and event-push, and of the service interfaces for heart rate, blood pressure, body temperature, respiration and blood oxygen saturation.

An informative annex gives JSON code examples for the general interface parameters. It defines vital signs, sensing devices, monitoring systems, coded character sets and transactions.

It applies to the design, production and use of vital signs sensing devices for IoT applications. It was issued on 11 October 2021 and has applied since 1 May 2022.

Found what you need?

Document preview — GB/T 40688-2021

National Standard of the People's Republic of China

ICS
35.040
Classification
L 78

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Abbreviations
  • 5 General
  • 5.1 Communication protocol
  • 5.2 Interface description
  • 5.3 Coded character set
  • 5.4 Data Type
  • 6 Interface message format
  • 6.1 Request message format
  • 6.2 Response message format
  • 7 Basic functions and parameters of general interface
  • 7.1 Request class interface
  • 7.2 Event Push Class Interface
  • 8 Basic functions and parameters of service interface
  • 8.1 Heart rate category
  • 8.2 Blood Pressure
  • 8.3 Body temperature category
  • 8.4 Respiratory
  • 8.5 Blood oxygen saturation class
  • Appendix A (informative) General data interface parameter JSON code example of vital sign sensing equipment
  • Reference

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.

1 Scope

This document specifies the general rules and interfaces for the data interface from vital sign sensing equipment to vital sign monitoring system for IoT applications The message format and the basic functions and parameter requirements of the general interface and business interface.

This document applies to the design, production and use of vital signs sensing devices for IoT applications.

2 Normative references

The content of the following documents constitutes an indispensable clause of this document through normative references in the text. Among them, dated quotations Only the version corresponding to the date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 13000-2010 Information Technology Universal Multi-octet Coded Character Set (UCS)

RFC2616 Hypertext Transfer Protocol 1.1 (Hypertext Transfer Protocol -- HTTP/1.1)

RFC4627 JSON Application and Media Type [The application/json Media Type for JavaScript Object Notation (JSON)]

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Vital signs

An indication used to determine the vital signs of the human body.

Note 1: Vital signs can be measured, and the normal range of indicators varies with race, gender, age, and weight.

Note 2: Including but not limited to five kinds of body temperature, blood pressure, heart rate, respiration and blood oxygen saturation.

3.2 Vital signs sensing device

A device that can obtain vital sign data or an IoT application-oriented device that obtains the status of vital signs based on vital sign data.

Note: Generally have data acquisition, data processing and communication capabilities.

3.3 Vital signs monitoring system

Receive, process and store vital sign perception data, and provide vital sign monitoring and management services for individuals, families, medical institutions and other users The information system can be equipped with vital signs sensing equipment.

3.4 Code character set

A set of clear rules, which establishes a one-to-one correspondence between the character set and the characters in the character set and their bit groups. [Source: GB/T 1988-1998, 4.6]

3.5 Transaction

The process of communication and interaction between the vital sign sensing device and the vital sign monitoring system.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 36 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 40688-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
36 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 40688-2021

$500.00