GB/T 40496-2021Determination of antioxidant content in jet fuel—High performance liquid chromatography (English PDF)

喷气燃料中抗氧剂含量的测定 高效液相色谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 40496-2021 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

August 20, 2021

Implementation date

March 1, 2022

Scope

GB/T 40496-2021 is the English-translated version of 喷气燃料中抗氧剂含量的测定 高效液相色谱法.

GB/T 40496-2021 describes how to measure antioxidants in jet fuel by high performance liquid chromatography.

It targets two additives, 2,6-di-tert-butyl-p-cresol (T501) and 2,4-dimethyl-6-tert-butylphenol, and offers two methods: Method A, with ultraviolet or diode array detection, for hydrocracked jet fuel, and Method B, liquid chromatography-mass spectrometry, for T501 in hydrocracked and hydrorefined jet fuel.

Under Method A the measuring range is 4.0 mg/L to 40.0 mg/L for T501 and 5.0 mg/L to 40.0 mg/L for the phenol; under Method B it is 3.5 mg/L to 50.0 mg/L for T501.

The sample is filtered through a membrane to remove particles, separated by liquid chromatography and quantified with an external standard. It was issued on 20 August 2021 and has applied since 1 March 2022.

Found what you need?

Document preview — GB/T 40496-2021

National Standard of the People's Republic of China

ICS
75.160.20
Classification
E 31

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Method summary
  • 5 Instruments

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.

1 Scope

This document describes the determination of 2,6-di-tert-butyl-p-cresol (T501) and 2,4-dimethyl-6-tert-butyl in jet fuel by high performance liquid chromatography Method of phenol content.

This document provides two methods. Method A (High Performance Liquid Chromatography-UV Detection) and Method B (Liquid Chromatography-Mass Spectrometry). Method A It is suitable for the determination of 2,6-di-tert-butyl-p-cresol (T501) and 2,4-dimethyl-6-tert-butylphenol in hydrocracking jet fuel.

The measuring range of 2,6-di-tert-butyl-p-cresol (T501) is 4.0mg/L~40.0mg/L, the determination of 2,4-dimethyl-6-tert-butylphenol content The range is 5.0mg/L~40.0mg/L; Method B is suitable for hydrocracking and hydrorefining 2,6-di-tert-butyl-p-cresol in jet fuel (T501) content determination, the determination range is 3.5mg/L~50.0mg/L.

2 Normative references

The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.

GB/T 4756 Manual sampling method for petroleum liquids

GB/T 6682 Analytical laboratory water specifications and test methods

GB/T 6683 Petroleum products test method precision data determination method

GB/T 27867 Petroleum liquid pipeline automatic sampling method

3 Terms and definitions

There are no terms and definitions that need to be defined in this document.

4 Method summary

The jet fuel sample is filtered through a filter membrane to remove particulate impurities, and then imported into high performance liquid chromatography for separation.

Method A is detected by ultraviolet detector or diode array detector, and method B is detected by mass detector. Method A sample 2,4- Dimethyl-6-tert-butylphenol and 2,6-di-tert-butyl-p-cresol (T501) content, method B sample contains 2,6-di-tert-butyl-p-cresol (T501) The quantities were quantified separately by the external standard method.

5 Instruments

5.1 High performance liquid chromatograph (HPLC): equipped with diode array detector or ultraviolet detector, the maximum allowable sample injection volume of the sample valve system […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 40496-2021

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 40496-2021

$225.00