Valid

GB/T 39526-2020Classification and test method for airborne sound insulation performance of curtain wall (English PDF)

建筑幕墙空气声隔声性能分级及检测方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (17 pages)

Need quotation for your management?

Get a formal quotation for GB/T 39526-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 14, 2020

Implementation date

November 1, 2021

Scope

GB/T 39526-2020 is the English-translated version of 建筑幕墙空气声隔声性能分级及检测方法.

GB/T 39526-2020 is the Chinese standard "Classification and test method for airborne sound insulation performance of curtain wall".

Its scope clause reads: This standard specifies the classification, testing methods and testing reports of the airborne sound insulation performance of building curtain walls: This standard is applicable to the classification and testing of airborne sound insulation performance of enclosure building curtain walls with sound insulation performance requirements:. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 39526-2020

National Standard of the People's Republic of China

ICS
91.060.10
Classification
P 32

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Rating
  • 5 Detection method
  • 6 Test report
  • Appendix C (informative appendix) Presentation format of test results

1 Scope

This standard specifies the classification, testing methods and testing reports of the airborne sound insulation performance of building curtain walls:

This standard is applicable to the classification and testing of airborne sound insulation performance of enclosure building curtain walls with sound insulation performance requirements:

2 Normative references

The following documents are indispensable for the application of this document: For dated reference documents, only the dated version applies to this article

Pieces: For undated references, the latest version (including all amendments) applies to this document:

GB/T 3947 Acoustic terms

GB/T 15173 Electroacoustic Sound Calibrator

GB/T 19889:1-2005 Acoustics Measurement of sound insulation of buildings and building components Part 1: Laboratory measurement of suppressed lateral sound transmission

Test facility requirements

GB/T 19889:3-2005 Acoustics Measurement of sound insulation of buildings and building components Part 3: Experiments on airborne sound insulation of building components

Room measurement

GB/T 34327 Terminology for building curtain walls

GB/T 50121-2005 Building Sound Insulation Evaluation Standard

ISO 10848-1 Acoustics Laboratory and site for lateral transmission of airborne sound, impact sound and building service equipment noise between adjacent rooms

Measurement Part 1: Framework document (Acoustics-Laboratoryand fieldmeasurementofflankingtransmissionfor airborne,impactandbuildingserviceequipmentsoundbetweenadjoiningrooms-Part 1:Framedocu- ment)

ISO 10848-2 Acoustics Laboratory and site for lateral transmission of airborne sound, impact sound and building service equipment noise between adjacent rooms

Measurement Part 2: Applied to Class B components (Acoustics-Laboratory and field measurement offlankingtransmissionforairborne, impactandbuildingserviceequipmentsoundbetweenadjoining rooms-Part 2:ApplicationtoTypeBelementswhenthejunctionhasasmalinfluence)

3 Terms and definitions

The following terms and definitions defined in GB/T 3947 and GB/T 34327 apply to this document:

3:1

Airbornesoundinsulationperformanceofcurtainwal

The ability of the building curtain wall to block airborne sound from spreading through it:

Note: The airborne sound insulation performance of building curtain walls includes the direct sound insulation performance of building curtain walls and the lateral sound insulation performance of building curtain walls:

3:2

Directairborne sound insulation performanceofcurtainwal

The ability of the building curtain wall to block airborne sound from the outdoor space through the building curtain wall itself to directly spread to the indoor space:

Note: The direct sound insulation performance of the building curtain wall airborne sound shall be tested according to the method specified in 5:2, characterized by the sound insulation R, and the weighted sound insulation and traffic noise spectrum […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Similar standards

How to Download GB/T 39526-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39526-2020

$300.00