Valid

GB/T 39270-2020Voltage dip indices and severity assessment method (English PDF)

电压暂降指标与严重程度评估方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 39270-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

November 19, 2020

Implementation date

June 1, 2021

Scope

GB/T 39270-2020 is the English-translated version of 电压暂降指标与严重程度评估方法.

GB/T 39270-2020 is the Chinese standard "Voltage dip indices and severity assessment method". Its scope clause reads: This standard specifies the connotation, calculation method and severity process of voltage sag indicators (including single event indicators, node indicators, and system indicators).

Degree evaluation method. This standard applies to AC 50Hz power systems. The index calculation and severity evaluation methods in this standard are also applicable to short-term interruptions. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 39270-2020

National Standard of the People's Republic of China

ICS
29.020
Classification
K 04

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Single event indicator of voltage sag
  • 4.1 Overview
  • 4.2 Energy Index
  • 4.3 Sag severity index
  • 5 Voltage sag node index
  • 5.1 Overview
  • 5.2 Node sag frequency
  • 5.3 Node SARFI indicator
  • 5.4 Node Energy Index
  • 5.5 Node sag severity index
  • 6 Voltage sag system indicators
  • 6.1 Overview
  • 6.2 System sag frequency
  • 6.3 System SARFI Index
  • 6.4 System Energy Index
  • 6.5 System sag severity index
  • 7 Evaluation method of voltage sag severity
  • 7.1 Evaluation Step 5 of the Severity of Voltage Sag
  • 7.2 Evaluation method for the severity of a single event sag
  • 7.3 Evaluation method of node sag severity
  • 7.4 Evaluation method of system sag severity
  • Appendix C (informative appendix) Calculation example of voltage sag severity index

1 Scope

This standard specifies the connotation, calculation method and severity process of voltage sag indicators (including single event indicators, node indicators, and system indicators).

Degree evaluation method.

This standard applies to AC 50Hz power systems. The index calculation and severity evaluation methods in this standard are also applicable to short-term interruptions.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this document.

For undated references, the latest version (including all amendments) applies to this document.

GB/T 30137-2013 Power quality voltage sag and short-term interruption

GB/T 32507-2016 Power quality terminology

3 Terms and definitions

The following terms and definitions defined in GB/T 30137-2013 and GB/T 32507-2016 apply to this document. For convenience

Used, the following repeatedly lists some terms and definitions of GB/T 30137-2013 and GB/T 32507-2016.

3.1 Voltage dip (sag)

The root mean square value of the power frequency voltage at a certain point in the power system suddenly decreases to 0.1pu~0.9pu, and after a short duration of 10ms~1min

Return to normal.

[GB/T 30137-2013, definition 3.1]

3.2 Short interruption

The root-mean-square value of the power frequency voltage at a certain point in the power system suddenly drops below 0.1pu, and resumes after a short duration of 10ms~1min normal phenomenon.

[GB/T 30137-2013, definition 3.2]

3.3 Voltage dip (short interruption) threshold

Used to judge the voltage sag (short-term interrupt) start and end and set the voltage threshold.

[GB/T 30137-2013, definition 3.3]

3.4 Voltage dip (short interruption) duration

The duration of the voltage sag (short-term interrupt) event that reaches the voltage sag (short-term interrupt) threshold.

[GB/T 30137-2013, definition 3.4]

3.5 Suspended (short interruption) frequency

The number of voltage sags (short-term interruptions) in a certain period of time.

[GB/T 30137-2013, definition 3.6] […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 39270-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39270-2020

$240.00