Scope

GB/T 39269-2020 is the English-translated version of 电压暂降/短时中断 低压设备耐受特性测试方法.

GB/T 39269-2020 is the Chinese standard "Voltage dip and short interruption—Immunity testing method for low voltage equipment".

Its scope clause reads: This standard specifies the test dimensions of the voltage sag and short-term interruption withstand characteristics of low-voltage equipment, the performance criteria of the equipment under test, the test equipment, Test layout, test requirements, test procedures and test results, reports and data formats.

This standard applies to electrical equipment with a rated voltage not exceeding 1kV and a rated frequency of 50Hz. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 39269-2020

National Standard of the People's Republic of China

ICS
29.020
Classification
K 04

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Test dimension
  • 4.1 Dimension order
  • 4.2 Residual voltage and duration
  • 4.3 Other features
  • 4.4 Types of voltage sag
  • 4.5 Working condition 3 of the equipment under test
  • 5 Performance criteria of the equipment under test
  • 6 Test equipment
  • 6.1 Voltage sag generator
  • 6.2 Data Acquisition System
  • 7 Test layout
  • 8 Test requirements
  • 8.1 Single-phase equipment
  • 8.2 Three-phase equipment
  • 9 Test process
  • 9.1 Test preparation
  • 9.2 Test implementation
  • 10 Test results
  • 11 Test report
  • 12 Test data format
  • Appendix A (normative appendix) Three-phase system voltage sag test phasor
  • Appendix B (informative appendix) Description of incremental method
  • Appendix C (informative appendix) Test report template

1 Scope

This standard specifies the test dimensions of the voltage sag and short-term interruption withstand characteristics of low-voltage equipment, the performance criteria of the equipment under test, the test equipment,

Test layout, test requirements, test procedures and test results, reports and data formats.

This standard applies to electrical equipment with a rated voltage not exceeding 1kV and a rated frequency of 50Hz.

2 Normative references

The following documents are indispensable for the application of this document. For dated reference documents, only the dated version applies to this article

Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB/T 17626.11-2008 Electromagnetic compatibility test and measurement technology Voltage sag, short-term interruption and voltage change immunity test

GB/T 17626.34-2012 Electromagnetic compatibility test and measurement technology The voltage of equipment with main power supply current greater than 16A per phase

Immunity test for dips, short interruptions and voltage changes

GB/T 30137-2013 Power quality voltage sag and short-term interruption

GB/T 32507-2016 Power quality terminology

3 Terms and definitions

GB/T 17626.34-2012, GB/T 30137-2013 and GB/T 32507-2016 defined and the following terms and definitions apply to

This document. For ease of use, GB/T 17626.34-2012, GB/T 30137-2013 and GB/T 32507-

Some terms and definitions in.2016.

3.1 Voltage dip

The root mean square value of the power frequency voltage at a certain point in the power system suddenly decreases to 0.1pu~0.9pu, and after a short duration of 10ms~1min

Return to normal.

[GB/T 30137-2013, definition 3.1]

3.2 Short interruption

The root-mean-square value of the power frequency voltage at a certain point in the power system suddenly drops below 0.1pu, and resumes after a short duration of 10ms~1min normal phenomenon.

[GB/T 30137-2013, definition 3.2]

3.3 Voltage sag tolerance

The ability of electrical equipment to maintain normal operation even when a voltage sag occurs in its power supply.

Note. Rewrite GB/T 32507-2016, definition 2.8.22.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 39269-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39269-2020

$240.00