GB/T 39090-2020Adiabatic storage test method for dangerous goods (English PDF)

危险品绝热储存试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 39090-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

September 29, 2020

Implementation date

April 1, 2021

Scope

GB/T 39090-2020 is the English-translated version of 危险品绝热储存试验方法.

GB/T 39090-2020 fixes the method for the adiabatic storage test of dangerous goods, covering the safety measures, the test equipment, the test procedure, the data processing and the test report.

Clause 1 states that it applies to the adiabatic storage test of dangerous goods, and the body opens with a warning that the test carries a potential explosion hazard and that the equipment must give test personnel enough protection.

The standard has no normative references clause: its contents run Scope, Terms and definitions, Safety measures, Test equipment, Test Step, Data processing and Test report, followed by four informative appendices on the adiabatic storage test device, the calculation of the heat loss rate per unit mass of packaging, IBC or tank, the determination of the self-accelerating decomposition temperature and an example of adiabatic storage test results.

The terms clause carries a single definition, self-accelerating decomposition temperature, quoted from GB 21178-2007 as the lowest ambient temperature at which self-accelerating decomposition of the substance may occur in a container used for transportation; a note there explains that the test determines how the heating rate of dangerous goods varies with temperature and that the heating parameters obtained, combined with heat loss data for the packaging concerned, give the self-accelerating decomposition temperature of the goods in their container, for every type of container including medium-sized bulk containers and tanks.

The safety clause warns that the sample may explode if the cooling system is switched on when the heat generation rate exceeds its cooling capacity, requires a safe test site to limit both the explosion hazard and a second explosion of decomposition gases, and requires the sample to be disposed of safely as soon as the test ends, since it may become more unstable and more sensitive afterwards.

The equipment clause calls for a 1.0 L or 1.5 L glass Dewar for the sample, a heat-insulating oven held to a temperature difference of plus or minus 0.1 degrees Celsius, an inert Dewar cap through which a tubular internal heater and a cooling tube of inert materials are inserted into the sample, a 2 m PTFE capillary that keeps the pressure inside the Dewar from rising, and auxiliary safety devices that cut off the oven power supply when the safe temperature limit is exceeded.

It also requires an armored thermocouple or platinum resistance sensor accurate to at least 0.1 degrees Celsius for the sample centre and a second one at the same height for the oven ambient temperature, with continuous measuring and recording equipment, the test equipment standing in a separate observation area, and samples whose self-accelerating decomposition temperature is below the ambient temperature tested in a cooling chamber or a solid carbon dioxide cooling oven.

The standard was proposed and is managed by the National Standardization Technical Committee for Management of Hazardous Chemicals (SAC/TC251), and the page records it under ICS 13.300 and the Chinese classification A80. It was issued on 2020-09-29 and has applied since 2021-04-01.

Found what you need?

Document preview — GB/T 39090-2020

National Standard of the People's Republic of China

ICS
13.300
Classification
A 80

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Preface
  • 1 Scope
  • 2 Terms and definitions
  • 3 Safety measures
  • 4 Test equipment
  • 5 Test Step
  • 6 Data processing
  • 7 Test report
  • Appendix A (informative appendix) Adiabatic storage test device
  • Appendix B (informative appendix) Calculation of heat loss rate (L) per unit mass of packaging, IBC or tank
  • Appendix C (informative appendix) Example 7 for determining the self-accelerating decomposition temperature
  • Appendix D (Informative Appendix) Example 8 of Dangerous Goods Adiabatic Storage Test Results

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies safety measures, test equipment, test procedures, data processing and test reports for the adiabatic storage test of dangerous goods.

This standard applies to the adiabatic storage test of dangerous goods.

2 Terms and definitions

The following terms and definitions apply to this document.

2.1 Self-accelerating decomposition temperature; SADT

The lowest ambient temperature at which self-accelerating decomposition of the substance may occur in a container used for transportation. [GB 21178-2007,3.3]

Note: The adiabatic storage test of dangerous goods is used to determine the heating rate of dangerous goods with temperature, and the obtained heating parameters are combined with the heat loss data of the relevant packaging It is used to determine the self-accelerating decomposition temperature of dangerous goods in its container. It is suitable for every type of container, including medium-sized bulk containers and tanks.

3 Security measures

3.1 If the cooling system is turned on when the heat generation rate exceeds the cooling capacity of the cooling system, the sample may explode. So it should be opened in time Cooling system and choose a safe test site to minimize possible explosion hazards and decomposition products to cause gas explosions (Second explosion) danger.

3.2 As soon as the test is completed, the sample should be treated safely and harmlessly. The sample may become more unstable and more sensitive after the test. You should be cautious. deal with.

4 Test equipment

4.1 The test equipment for the adiabatic storage of dangerous goods includes a glass Dewar (1.0L or 1.5L) for the sample, a A heat-insulating oven with a temperature difference of ±0.1°C and an inert Dewar cap. Under special circumstances, other materials can be used for the sample container. Pick A disc tubular internal heater and cooling tube made of inert materials are inserted into the sample through the bottle cap. Insert a 2m length into the heat-insulating bottle cap The PTFE capillary tube prevents the pressure inside the Dewar from rising. The heating power of the internal heater can be adjusted to heat the Set temperature or use for calibration. When the sample in the Dewar reaches the preset temperature, it can automatically stop internal heating or start cooling. In addition to the cooling system, The equipment should also be equipped with auxiliary safety devices to cut off the power supply of the oven when the safe temperature limit is exceeded. Schematic diagram of adiabatic storage test see Appendix A.

4.2 Use an armored thermocouple or platinum resistance sensor with an accuracy of at least 0.1°C to measure the temperature of the sample at the center of the sample. Same use The thermocouple or platinum resistance sensor is measured at the same height as the temperature point of the measurement sample to obtain the ambient temperature in the oven. Need to use continuous The temperature measuring and recording equipment monitors the sample temperature and the ambient temperature in the oven. The test equipment should be placed in a separate observation area. for For samples whose self-accelerating decomposition temperature is lower than the ambient temperature, the test should be carried out in a cooling chamber, or a solid carbon dioxide cooling oven.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 39090-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 39090-2020

$210.00