GB/T 38979-2020Sanitary wares—Test method for flushing noise of toilet (English PDF)

卫生陶瓷 坐便器冲洗噪声试验方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (19 pages)

Need quotation for your management?

Get a formal quotation for GB/T 38979-2020 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 21, 2020

Implementation date

June 1, 2021

Scope

GB/T 38979-2020 is the English-translated version of 卫生陶瓷 坐便器冲洗噪声试验方法.

GB/T 38979-2020 is the Chinese standard "Sanitary wares - Test method for flushing noise of toilet".

Its scope clause reads: This Standard specifies the facility conditions and measuring instruments, sample installation and commissioning, sound pressure level measurement, result calculation, uncertainty of measurement and test report for flushing noise detection of toilets (not including toilets and smart toilets that use pressure flushing devices).

This Standard applies to the flushing noise detection of toilets (not including toilets and smart toilets that use pressure flushing devices).

Its clauses include terms and definitions; facility conditions and measuring instruments; sample installation and commissioning; sound pressure level measurement; result calculation; uncertainty of measurement; test report.

It was issued by the State Administration for Market Regulation on JULY 21, 2020 and took effect on JUNE 01, 2021.

Found what you need?

Document preview — GB/T 38979-2020

National Standard of the People's Republic of China

ICS
91.140.70
Classification
Q 31

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions5
  • 4 Facility conditions and measuring instruments5
  • 5 Sample installation and commissioning6
  • 6 Sound pressure level measurement7
  • 7 Result calculation10
  • 8 Uncertainty of measurement14
  • 9 Test report19

Foreword

This Standard was drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This Standard specifies the facility conditions and measuring instruments, sample installation and commissioning, sound pressure level measurement, result calculation, uncertainty of measurement and test report for flushing noise detection of toilets (not including toilets and smart toilets that use pressure flushing devices).

This Standard applies to the flushing noise detection of toilets (not including toilets and smart toilets that use pressure flushing devices).

2 Normative references

The following documents are indispensable for the application of this document.

For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 3768-2017, Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Survey method using an enveloping measurement surface over a reflecting plane

GB/T 3785.1, Electroacoustics - Sound level meters - Part 1: Specifications

GB/T 6952, Sanitary wares

GB/T 15173, Electroacoustics - Sound calibrators

GB/T 26730, Sanitary ware - Gravity water flushing devices and supports

JC/T 764, WC seats

JC/T 932, Drainage fittings for sanitary wares

ISO 3744, Acoustics - Determination of sound power levels and sound energy levels of noise sources using sound pressure - Engineering methods for an essentially free field over a reflecting plane

3 Terms and definitions

Terms and definitions determined by GB/T 3768-2017, GB/T 6952, and the following ones are applicable to this document.

3.1 Measurement time interval

It is used to determine the time of integration of the sound level meter for the A- weighted cumulative percentage sound pressure level of the flushing noise of the to-be-tested toilet sample.

3.2 Standard test operator

The personnel who are required to operate the to-be-tested toilet sample to complete the flushing process.

4 Facility conditions and measuring instruments

4.1 Test room

The test room should be a semi-anechoic room or a rigid-wall room; the background noise on the hemispherical measurement surface shall be more than 3 dB(A) lower than the average value of the A-weighted equivalent sound level LAeq of the flushing noise of the to-be-tested toilet sample.

4.2 Measuring instruments

The sound level meter for measurement shall meet the requirements for Grade- 2 instrument in GB/T 3785.1; it is recommended to use a Grade-1 instrument.

The sound calibrator shall meet the Grade-1 accuracy requirements in GB/T 15173.

5 Sample installation and commissioning

5.1 Sample quantity and specifications

Take a toilet sample.

5.2 Toilet matching requirements

5.2.1 For matching products, install the to-be-tested toilet sample in accordance with the manufacturer's instructions; conduct a connection tightness test under the test static pressure of 0.14 MPa ± 0.01 MPa, to ensure that the toilet and its flushing devices have the overall tightness in good condition.

5.2.2 For non-matching products, the to-be-tested toilet sample can be equipped with a gravity flushing device that meets the requirements of rated water consumption, has an anti-siphon function and meets the requirements of GB/T 26730; the working water level of the flushing tank shall meet the needs of the normal flushing process.

5.3 Installation and orientation of the toilet sample

Place the to-be-tested floor-type toilet sample or the sanitary ware support that contains the wall-mounted toilet sample on the floor of the semi-anechoic room or rigid-wall room; make the distance between the center and any wall not less than 1.5 m.

6 Sound pressure level measurement

6.1 Determination of size of the sound source reference body

Use the to-be-tested toilet sample as the sound source reference body; put down the toilet seat; lift the cover.

6.4 Sound pressure level measurement procedures

6.4.1 In a semi-anechoic room or a rigid-wall room that meets the requirements, locate each measurement point according to the microphone position coordinates on the hemispherical measurement surface. Then, move the sound level meter to the position of each measurement point in turn; ensure that the orientation of the microphone is the same as the incident angle of the sound wave when it is calibrated and it perpendicularly points to the measuring surface. Position number

6.4.4 Before testing the flushing noise of the toilet sample, it shall meet the requirements for water consumption in GB/T 6952.

6.4.5 Under the specified test static pressure, start the flushing device and time it in the normal way (generally no more than 1 s); use the A-weighted fast-time weighting characteristic "F" of the sound level meter to respectively measure the A-weighted cumulative percentage sound pressure levels LpAi(50) and LpAi(10) of the toilet flushing noise on the hemispheric measurement surface and record them.

7 Result calculation

7.1 Calculation of the average value of A-weighted cumulative percentage

sound pressure level

7.2 Background noise correction

The background noise correction values K1A(50) and K1A(10) of the A-weighted cumulative percentage sound pressure level are calculated according to Formula (5) and Formula (6) respectively.

7.3 Test environment correction

Calculate the environment correction value K2A according to Formula (7).

7.5 Calculation of the sound power level

During the normal flushing cycle, the sound power levels LWA (50) and LWA (10) under the meteorological conditions of the test site are calculated according to Formula (10) and Formula (11) respectively.

8 Uncertainty of measurement

8.1 Combined standard uncertainty uLWA of the A-weighted sound power

level measurement The uncertainty uLWA of the toilet flushing noise sound power level that is measured according to this Standard is characterized by its total standard deviation sigma tot; it's calculated according to Formula (12).

8.2 Determination of sigma omc

Under the test static pressure of 0.14 MPa ± 0.01 MPa, the same standard test operator uses the same sound level meter, and, according to the test procedures that are specified in Chapter 6, uses the point that is numbered 10 on the hemispheric measurement surface as the microphone position coordinate,

8.3 Determination of sigma R0

8.3.1 Reproducibility standard deviation sigma R0

Reproducibility standard deviation sigma R0 includes measurement method, repeatability of sound pressure level measurement, measurement surface area, background noise correction, test environment correction, meteorological condition correction, sound level meter performance, number of measurement points, angle difference between the noise source acoustic emission direction and the measurement surface normal, frequency spectrum shape and tuned sound and other uncertainty components; it's calculated according to Formula (15).

8.3.7 Uncertainty caused by the meteorological condition correction

The uncertainty, which is caused by the reference quantity difference that is used for sound pressure level and sound power level, and the change of sound power level with temperature and pressure, is umet = 0.3 dB; the sensitivity coefficient is cmet = 1.When the altitude of the test site is less than 1 500 m, no meteorological condition correction is required; when the altitude is greater than 1 500 m, perform the meteorological condition correction in accordance with ISO 3744.

8.3.10 Uncertainty caused by the angle difference between the sound

source acoustic emission direction and the measurement surface normal In a semi-anechoic room, the uncertainty which is caused by the angle difference between the acoustic emission direction of the toilet flushing noise and the hemispherical measurement surface normal is uangle = 0.25 dB; the sensitivity coefficient is cangle = 10-0.1K2A. For a rigid-walled room, it is recommended to analyze the influence of the sound source and its directivity, measurement distance and other factors to determine the standard uncertainty reasonably.

9 Test report

The test report shall include the following. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 38979-2020

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
19 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 38979-2020

$210.00