GB/T 37508-2019 is the English-translated version of 造型黏土中防腐剂的测定 高效液相色谱法.
GB/T 37508-2019 is the Chinese standard "Determination of preservatives in moulding clay - High performance liquid chromatography method". Its scope clause reads: This standard specifies the method for the determination of preservatives in modeling clay (also known as "color mud") by high-performance liquid chromatography.
This standard applies to children's labor, school teaching, model design, art modeling, etc., using flour or polymer resin as the main material 2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, phenol, 1,2-benzyl isothiazolin- 3-keto Determination.
Its clauses include principle; reagents and materials; instruments and equipment; analysis steps; results calculation; limit of detection and limit of quantitation; precision; phenol 108-95-2 c6h5oh.
Found what you need?
Document preview — GB/T 37508-2019
National Standard of the People's Republic of China
- ICS
- 97.190
- Classification
- Y 57
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Principle
- 4 Reagents and materials
- 5 Instruments and equipment
- 6 Analysis steps
- 7 Results calculation
- 8 Limit of detection and limit of quantitation
- 9 Precision
- 3 Phenol 108-95-2 C6H5OH
1 Scope
This standard specifies the method for the determination of preservatives in modeling clay (also known as "color mud") by high-performance liquid chromatography.
This standard applies to children's labor, school teaching, model design, art modeling, etc., using flour or polymer resin as the main material
2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, phenol, 1,2-benzyl isothiazolin- 3-keto
Determination.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this article
Pieces. For undated references, the latest version (including all amendments) applies to this document.
GB/T 6682 Analytical laboratory water specifications and test methods
3 Principle
2-methyl-4-isothiazoline-3-one, 5-chloro-2-methyl-4-isothiazoline-3-one, phenol, 1,2-benzylisothiazoline- 3-keto meridian
Ultrasonic extraction, filtration, determination by high performance liquid chromatography, qualitative analysis based on retention time, quantification by external standard method
4 Reagents and materials
Unless otherwise specified, only analytical grade reagents or above are used.
4.1
Water, GB/T 6682, secondary.
4.2 Methanol
chromatographically pure.
4.3 Reference materials
2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, phenol, 1,2-benzylisothiazoline -3-
Ketone, purity is not less than 98.0%. See Appendix A for the English name, CAS registration number and molecular formula of the reference material.
4.4 Standard stock solution
Weigh 10 mg (accurate to 0.1 mg) of 2-methyl-4-isothiazolin-3-one (4.3) and 5-chloro-2-methyl-4-isothia
The oxazolin-3-one (4.3), phenol (4.3), and 1,2-benzylisothiazolin-3-one (4.3) were placed in 4 different 10 mL volumetric flasks, and
The alcohol (4.2) is dissolved, the volume is adjusted to the mark, and shaken to obtain 2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, Phenol, 1,
A standard stock solution of 2-benzylisothiazolin-3-one at a concentration of 1000 mg/L. Stored at 0 °C ~ 4 °C, the validity period of standard stock solution is
3 months.
4.5 Mixed standard intermediate solution
0.5mL of 2-methyl-4-isothiazoline-3-one and 1mL of 5-chloro-2-methyl-4-isothiazoline-3-
Ketone, 2 mL of phenol, and 2 mL of 1,2-benzyl isothiazolin-3-one standard stock solution (4.4) in the same 10 mL volumetric flask with methanol (4.2)
Make up to volume and shake to obtain 2-methyl-4-isothiazolin-3-one concentration of 50mg/L, 5-chloro-2-methyl-4-isothiazolin-3-one concentration
A mixed standard intermediate solution of 100 mg/L, a phenol concentration of.200 mg/L, and a 1,2-benzylisothiazolin-3-one concentration of.200 mg/L.
4.6 Mixed standard working solution
Pipette mixed standard intermediate solution (4.5) 0.1mL, 0.2mL, 0.4mL, 1mL, 2mL in 5 10mL
In a volumetric flask, make up to volume with methanol (4.2) and shake to obtain 5 mixed standard working solutions of different concentrations. Mixed standard working solution
The concentration of each component is shown in Table 1.
Table 1 Concentration of each component in the mixed standard working solution name concentration mg/L
2-methyl-4-isothiazolin-3-one 0.5 1.0 2.0 5.0 10.0
5-chloro-2-methyl-4-isothiazolin-3-one 1.0 2.0 4.0 10.0 20.0
Phenol 2.0 4.0 8.0 20.0 40.0
1,2-benzylisothiazolin-3-one 2.0 4.0 8.0 20.0 40.0
4.7 Filter
Organic filter with a pore size of 0.45 µm.
5 Instruments and equipment
5.1 High Performance Liquid Chromatograph
equipped with UV variable wavelength detector.
5.2 Electronic balance
Sensitivity 0.1mg.
5.3
Ultrasonic cleaner.
5.4
Vortex mixer.
6 Analysis steps
6.1 Sample processing
Cut the sample into small pieces less than 3mm × 3mm × 3mm, and weigh 0.5g (accurate to 0.1mg) small samples in 10mL
In a centrifuge tube with a stopper, add 10 mL of methanol (4.2), seal, vortex on a vortex mixer (5.4) for 1 min, sonicate for 60 min, and cool
It was measured at room temperature after filtration through a filter (4.7).
6.2 Instrument settings
The measurement conditions of the high performance liquid chromatography (5.1) are set as follows.
a) Chromatographic column. C18 column (250mm × 4.6mm, 5µm), or equivalent column;
b) Mobile phase. methanol water = 20 80 (volume ratio);
c) Flow rate. 1.0mL/min;
d) Detection wavelength. 2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, phenol, 275nm; different
Thiazolin-3-one, 320nm;
e) Column temperature. 35 °C;
f) injection volume. 10 µL;
g) running time. 30min;
h) Post-running time. 10min.
Note. The chromatographic conditions such as flow ratio and flow rate vary with the instrument.The operator can choose the best operating conditions according to the test to make the target peak and interference peaks completely
Separation.
6.3 Determination
Under the chromatographic conditions set in 6.2, take the mixed standard working solution (4.6) and inject them separately. Record the chromatogram.
The area is the ordinate and a standard working curve is drawn.
Take a sample of the test solution obtained in 6.1 and record the chromatogram to characterize the retention time. Measure the peak area and obtain it according to the standard working curve.
The mass concentration of each component in the test solution. The response value of the test object in the sample solution should be within the linear range of the standard curve and exceed the line.
The range should be determined after dilution.
2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, phenol, and 1,2-benzylisothiazolin-3-one Mixed standard
See Appendix B for the liquid chromatogram of the working solution.
6.4 Blank test
Except that the sample is not weighed, the same test procedure (6.1 ~ 6.3) as the sample test is adopted.
7 Results calculation
The result is calculated according to formula (1).
wi = (ci-c0) × m × f (1)
Where.
wi --- the content of the measured component in the sample, the unit is milligram per kilogram (mg/kg);
ci --- Obtain the mass concentration of the component to be measured in the sample solution from the standard working curve, the unit is milligram per liter (mg/L);
c0 --- Obtain the mass concentration of the component to be measured in the blank solution from the standard working curve, the unit is milligram per liter (mg/L);
V --- sample solution volume, unit is milliliter (mL);
f --- dilution factor;
m --- sample mass in grams (g).
The calculation results retain two significant digits.
8 Limit of detection and limit of quantitation
The detection limit of 2-methyl-4-isothiazolin-3-one and 5-chloro-2-methyl-4-isothiazolin-3-one is 0.9 mg/kg, and the limit of quantification is 3.0 mg/kg;
The detection limit of phenol and 1,2-benzylisothiazolin-3-one was 1.8 mg/kg, and the limit of quantification was 6.0 mg/kg.
9 Precision
The absolute difference between two independent determination results obtained under repeatable conditions should not exceed 10% of the arithmetic mean.
Appendix A (Normative appendix)
Chinese name, English name, CAS number and molecular formula of the standard substance
The Chinese name, English name, CAS number and molecular formula of the standard substance are shown in Table A.1.
Table A.1 Chinese name, English name, CAS number and molecular formula of the reference material
Serial number Chinese name English name CAS number Molecular formula
1 2-methyl-4-isothiazolin-3-one 2-Methyl-4-isothiazolin-3-one 2682-20-4 C4H5NOS
2 5-chloro-2-methyl-4-isothiazolin-3-one 5-Chloro-2-methyl-4-isothiazolin-3-one 26172-55-4 C4H5Cl2NOS
3 Phenol 108-95-2 C6H5OH
4 1,2-Benzylisothiazolin-3-one 1,2-Benzisothiazolin-3-one 2634-33-5 C7H5NOS
Appendix B (Informative appendix)
Liquid chromatogram of mixed standard working solution
A typical chromatogram of a mixed standard working solution is shown in Figure B.1.
Explanation.
1--2-methyl-4-isothiazolin-3-one (3.529min);
2 --- 5-chloro-2-methyl-4-isothiazolin-3-one (11.367min);
3--phenol (18.423min);
4 --- 1,2-benzylisothiazolin-3-one (25.100min).
Figure B.1 Liquid chromatogram of a mixed standard working solution […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Similar standards
How to Download GB/T 37508-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Fast delivery
After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
GB/T 37508-2019
$85.00