Valid

GB/T 37508-2019Determination of preservatives in moulding clay - High performance liquid chromatography method (English PDF)

造型黏土中防腐剂的测定 高效液相色谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 37508-2019 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

June 4, 2019

Implementation date

October 1, 2019

Scope

GB/T 37508-2019 is the English-translated version of 造型黏土中防腐剂的测定 高效液相色谱法.

GB/T 37508-2019 is the Chinese standard "Determination of preservatives in moulding clay - High performance liquid chromatography method". Its scope clause reads: This standard specifies the method for the determination of preservatives in modeling clay (also known as "color mud") by high-performance liquid chromatography.

This standard applies to children's labor, school teaching, model design, art modeling, etc., using flour or polymer resin as the main material 2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, phenol, 1,2-benzyl isothiazolin- 3-keto Determination.

Its clauses include principle; reagents and materials; instruments and equipment; analysis steps; results calculation; limit of detection and limit of quantitation; precision; phenol 108-95-2 c6h5oh.

Found what you need?

Document preview — GB/T 37508-2019

National Standard of the People's Republic of China

ICS
97.190
Classification
Y 57

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Principle
  • 4 Reagents and materials
  • 5 Instruments and equipment
  • 6 Analysis steps
  • 7 Results calculation
  • 8 Limit of detection and limit of quantitation
  • 9 Precision
  • 3 Phenol 108-95-2 C6H5OH

1 Scope

This standard specifies the method for the determination of preservatives in modeling clay (also known as "color mud") by high-performance liquid chromatography.

This standard applies to children's labor, school teaching, model design, art modeling, etc., using flour or polymer resin as the main material

2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, phenol, 1,2-benzyl isothiazolin- 3-keto

Determination.

2 Normative references

The following documents are essential for the application of this document. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest version (including all amendments) applies to this document.

GB/T 6682 Analytical laboratory water specifications and test methods

3 Principle

2-methyl-4-isothiazoline-3-one, 5-chloro-2-methyl-4-isothiazoline-3-one, phenol, 1,2-benzylisothiazoline- 3-keto meridian

Ultrasonic extraction, filtration, determination by high performance liquid chromatography, qualitative analysis based on retention time, quantification by external standard method

4 Reagents and materials

Unless otherwise specified, only analytical grade reagents or above are used.

4.1

Water, GB/T 6682, secondary.

4.2 Methanol

chromatographically pure.

4.3 Reference materials

2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, phenol, 1,2-benzylisothiazoline -3-

Ketone, purity is not less than 98.0%. See Appendix A for the English name, CAS registration number and molecular formula of the reference material.

4.4 Standard stock solution

Weigh 10 mg (accurate to 0.1 mg) of 2-methyl-4-isothiazolin-3-one (4.3) and 5-chloro-2-methyl-4-isothia

The oxazolin-3-one (4.3), phenol (4.3), and 1,2-benzylisothiazolin-3-one (4.3) were placed in 4 different 10 mL volumetric flasks, and

The alcohol (4.2) is dissolved, the volume is adjusted to the mark, and shaken to obtain 2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, Phenol, 1,

A standard stock solution of 2-benzylisothiazolin-3-one at a concentration of 1000 mg/L. Stored at 0 °C ~ 4 °C, the validity period of standard stock solution is

3 months.

4.5 Mixed standard intermediate solution

0.5mL of 2-methyl-4-isothiazoline-3-one and 1mL of 5-chloro-2-methyl-4-isothiazoline-3-

Ketone, 2 mL of phenol, and 2 mL of 1,2-benzyl isothiazolin-3-one standard stock solution (4.4) in the same 10 mL volumetric flask with methanol (4.2)

Make up to volume and shake to obtain 2-methyl-4-isothiazolin-3-one concentration of 50mg/L, 5-chloro-2-methyl-4-isothiazolin-3-one concentration

A mixed standard intermediate solution of 100 mg/L, a phenol concentration of.200 mg/L, and a 1,2-benzylisothiazolin-3-one concentration of.200 mg/L.

4.6 Mixed standard working solution

Pipette mixed standard intermediate solution (4.5) 0.1mL, 0.2mL, 0.4mL, 1mL, 2mL in 5 10mL

In a volumetric flask, make up to volume with methanol (4.2) and shake to obtain 5 mixed standard working solutions of different concentrations. Mixed standard working solution

The concentration of each component is shown in Table 1.

Table 1 Concentration of each component in the mixed standard working solution name concentration mg/L

2-methyl-4-isothiazolin-3-one 0.5 1.0 2.0 5.0 10.0

5-chloro-2-methyl-4-isothiazolin-3-one 1.0 2.0 4.0 10.0 20.0

Phenol 2.0 4.0 8.0 20.0 40.0

1,2-benzylisothiazolin-3-one 2.0 4.0 8.0 20.0 40.0

4.7 Filter

Organic filter with a pore size of 0.45 µm.

5 Instruments and equipment

5.1 High Performance Liquid Chromatograph

equipped with UV variable wavelength detector.

5.2 Electronic balance

Sensitivity 0.1mg.

5.3

Ultrasonic cleaner.

5.4

Vortex mixer.

6 Analysis steps

6.1 Sample processing

Cut the sample into small pieces less than 3mm × 3mm × 3mm, and weigh 0.5g (accurate to 0.1mg) small samples in 10mL

In a centrifuge tube with a stopper, add 10 mL of methanol (4.2), seal, vortex on a vortex mixer (5.4) for 1 min, sonicate for 60 min, and cool

It was measured at room temperature after filtration through a filter (4.7).

6.2 Instrument settings

The measurement conditions of the high performance liquid chromatography (5.1) are set as follows.

a) Chromatographic column. C18 column (250mm × 4.6mm, 5µm), or equivalent column;

b) Mobile phase. methanol water = 20 80 (volume ratio);

c) Flow rate. 1.0mL/min;

d) Detection wavelength. 2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, phenol, 275nm; different

Thiazolin-3-one, 320nm;

e) Column temperature. 35 °C;

f) injection volume. 10 µL;

g) running time. 30min;

h) Post-running time. 10min.

Note. The chromatographic conditions such as flow ratio and flow rate vary with the instrument.The operator can choose the best operating conditions according to the test to make the target peak and interference peaks completely

Separation.

6.3 Determination

Under the chromatographic conditions set in 6.2, take the mixed standard working solution (4.6) and inject them separately. Record the chromatogram.

The area is the ordinate and a standard working curve is drawn.

Take a sample of the test solution obtained in 6.1 and record the chromatogram to characterize the retention time. Measure the peak area and obtain it according to the standard working curve.

The mass concentration of each component in the test solution. The response value of the test object in the sample solution should be within the linear range of the standard curve and exceed the line.

The range should be determined after dilution.

2-methyl-4-isothiazolin-3-one, 5-chloro-2-methyl-4-isothiazolin-3-one, phenol, and 1,2-benzylisothiazolin-3-one Mixed standard

See Appendix B for the liquid chromatogram of the working solution.

6.4 Blank test

Except that the sample is not weighed, the same test procedure (6.1 ~ 6.3) as the sample test is adopted.

7 Results calculation

The result is calculated according to formula (1).

wi = (ci-c0) × m × f (1)

Where.

wi --- the content of the measured component in the sample, the unit is milligram per kilogram (mg/kg);

ci --- Obtain the mass concentration of the component to be measured in the sample solution from the standard working curve, the unit is milligram per liter (mg/L);

c0 --- Obtain the mass concentration of the component to be measured in the blank solution from the standard working curve, the unit is milligram per liter (mg/L);

V --- sample solution volume, unit is milliliter (mL);

f --- dilution factor;

m --- sample mass in grams (g).

The calculation results retain two significant digits.

8 Limit of detection and limit of quantitation

The detection limit of 2-methyl-4-isothiazolin-3-one and 5-chloro-2-methyl-4-isothiazolin-3-one is 0.9 mg/kg, and the limit of quantification is 3.0 mg/kg;

The detection limit of phenol and 1,2-benzylisothiazolin-3-one was 1.8 mg/kg, and the limit of quantification was 6.0 mg/kg.

9 Precision

The absolute difference between two independent determination results obtained under repeatable conditions should not exceed 10% of the arithmetic mean.

Appendix A (Normative appendix)

Chinese name, English name, CAS number and molecular formula of the standard substance

The Chinese name, English name, CAS number and molecular formula of the standard substance are shown in Table A.1.

Table A.1 Chinese name, English name, CAS number and molecular formula of the reference material

Serial number Chinese name English name CAS number Molecular formula

1 2-methyl-4-isothiazolin-3-one 2-Methyl-4-isothiazolin-3-one 2682-20-4 C4H5NOS

2 5-chloro-2-methyl-4-isothiazolin-3-one 5-Chloro-2-methyl-4-isothiazolin-3-one 26172-55-4 C4H5Cl2NOS

3 Phenol 108-95-2 C6H5OH

4 1,2-Benzylisothiazolin-3-one 1,2-Benzisothiazolin-3-one 2634-33-5 C7H5NOS

Appendix B (Informative appendix)

Liquid chromatogram of mixed standard working solution

A typical chromatogram of a mixed standard working solution is shown in Figure B.1.

Explanation.

1--2-methyl-4-isothiazolin-3-one (3.529min);

2 --- 5-chloro-2-methyl-4-isothiazolin-3-one (11.367min);

3--phenol (18.423min);

4 --- 1,2-benzylisothiazolin-3-one (25.100min).

Figure B.1 Liquid chromatogram of a mixed standard working solution […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

How to Download GB/T 37508-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Fast delivery

    After payment you'll receive an email confirmation. The English PDF is sent to the same address, usually within minutes and at the latest within 1 business day.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Fast delivery
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37508-2019

$85.00