Valid

GB/T 37382-2019Optical functional films—Films for backlight unit of liquid crystal display—High temperature and high humidity aging measurement (English PDF)

光学功能薄膜 液晶显示背光模组用薄膜 高温高湿老化性能测定方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 37382-2019 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

March 25, 2019

Implementation date

February 1, 2020

Scope

GB/T 37382-2019 is the English-translated version of 光学功能薄膜 液晶显示背光模组用薄膜 高温高湿老化性能测定方法.

GB/T 37382-2019 is the Chinese standard "Optical functional films - Films for backlight unit of liquid crystal display - High temperature and high humidity aging measurement".

Its scope clause reads: This Standard specifies the measurement method of high temperature and high humidity aging of optical functional films for backlight unit of liquid crystal display.

This Standard is applicable to the measurement of high temperature and high humidity aging of optical functional films for backlight unit of liquid crystal display.

Its clauses include devices; specimen; test environment; test steps; result expression; test report. It was issued by the State Administration for Market Regulation on MARCH 25, 2019 and took effect on FEBRUARY 01, 2020.

Found what you need?

Document preview — GB/T 37382-2019

National Standard of the People's Republic of China

ICS
71.080.99
Classification
G 15

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Devices4
  • 4 Specimen5
  • 5 Test environment5
  • 6 Test steps5
  • 7 Result expression7
  • 8 Test report7

1 Scope

This Standard specifies the measurement method of high temperature and high humidity aging of optical functional films for backlight unit of liquid crystal display.

This Standard is applicable to the measurement of high temperature and high humidity aging of optical functional films for backlight unit of liquid crystal display.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB/T 2410, Determination of the luminous transmittance and haze of transparent plastics

GB/T 6739, Paints and varnishes - Determination of film hardness by pencil test

GB/T 9286, Paints and varnishes - Cross cut test for films

GB/T 25257, Optical functional films - Determination of warping degree

HG/T 4915, White reflective films - Determination of reflectance

3 Devices

3.1 Constant temperature and humidity aging box

Meet: maximum temperature >=65°C, maximum relative humidity >=95%, and continuous operation for more than 500h. Temperature accuracy: ±0.5°C.

2 - Specimen.

6 Test steps

6.5 Aging test

Set the constant temperature and humidity aging box as: testing temperature is 65°C and the relative testing humidity is 95%. When the set temperature and humidity are reached, put the specimen into the box. Conduct the 500h aging test to Group A3, Group A4, Group A5, Group A6, Group B1 and Group B2 specimens obtained according to 6.4. It must not interrupt during the test process.

6.6 Specimen balance after aging

After the test ends, place Group A3, Group A4, Group A5, Group A6, Group B1 and Group B2 specimens obtained according to 6.5 on the platform. Treat them according to the provisions of Clause 5.

6.7 Performance testing after aging

Respectively test adhesion, hardness, light transmittance, haze and warpage to post-test specimens of Group A3, Group A4, Group A5 and Group A6 obtained according to 6.6. Respectively test warpage and reflectivity to post-test specimens of Group B1 and Group B2.

In addition, the testing areas of specimen adhesion, hardness, light transmittance, haze and reflectance shall be beyond by 5mm or more around the edges and the clamping area.

7 Result expression

Compare with the testing results of Group A1, Group A2, Group A5, Group A6, Group B1 and Group B2 specimens before aging test, record, compare, calculate and analyze each performance parameter of Group A3, Group A4, Group A5, Group A6, Group B1 and Group B2 specimens after aging test. And determine the results.

8 Test report

The test report shall contain the following information:

a) reference to this Standard;

b) detailed instructions required to identify specimen, such as specimen […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 37382-2019

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 37382-2019

$75.00