GB/T 37254-2018High purity silicon carbide—Determination of trace elements (English PDF)
高纯碳化硅 微量元素的测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 37254-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 28, 2018
Implementation date
September 1, 2019
Scope
GB/T 37254-2018 is the English-translated version of 高纯碳化硅 微量元素的测定.
GB/T 37254-2018 gives two methods for measuring trace elements in high purity silicon carbide with a mass fraction of at least 99.9%: inductively coupled plasma optical emission spectrometry (ICP-OES) and inductively coupled plasma mass spectrometry (ICP-MS).
It covers 16 elements: aluminium, arsenic, calcium, chromium, copper, iron, mercury, potassium, magnesium, manganese, sodium, nickel, lead, sulfur, titanium and zinc.
The standard lists the reagents and standard solutions, the instruments and the sample preparation, either by fusion with sodium carbonate and borax in a platinum crucible or by pressurized acid digestion in a PTFE vessel, plus the blank solution.
It then describes the calibration curves, the blank test, the four parallel determinations, the calculation of results and the precision, with recommended instrument conditions and spectral lines in Annex A. It was issued on 28 December 2018 and has applied since 1 September 2019.
Found what you need?
Document preview — GB/T 37254-2018
National Standard of the People's Republic of China
- ICS
- 71.040.50
- Classification
- A 43
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Principles5
- 4 Reagents or materials5
- 5 Instruments and equipment6
- 6 Samples6
- 7 Test steps8
- 8 Results calculation and expression9
- 9 Precision10
- Appendix A (Informative) Recommended instrument working conditions and wavelength list of spectral lines of each element analysis11
1 Scope
This standard specifies a method for determining the content of trace elements in high-purity silicon carbide, by inductively coupled plasma atomic emission spectroscopy (ICP-OES) method and inductively coupled plasma mass spectroscopy (ICP-MS) method.
This standard is applicable to the determination of 16 elements such as aluminum, arsenic, calcium, chromium, copper, iron, mercury, potassium, magnesium, manganese, sodium, nickel, lead, sulfur, titanium, zinc in high-purity silicon carbide materials, which have a mass fraction content of more than or equal to 99.9%. The measurement range of each element is shown in Table 1 (based on mass fraction).
2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard.
GB/T 602 Chemical reagent -- Preparations of standard solutions for impurity
GB/T 6682 Water for analytical laboratory use -- Specification and test methods
3 Principles
3.1 ICP-OES method
After the sample is melted and decomposed with sodium carbonate and borax at high temperature or dissolved with acid pressurization, it is excited in an inductively coupled plasma torch flame, to emit the characteristic spectrum lines of the elements contained.
The content of the corresponding elements is determined according to the intensity of the characteristic spectrum lines of the elements to be measured.
3.2 ICP-MS method
After the sample is dissolved with acid pressurized, it is excited in an inductively coupled plasma torch flame. The ionized ions are separated by a quadrupole and collected by a photomultiplier tube. The content of the corresponding element is determined based on the intensity of the mass number of elements to be measured.
4 Reagents or materials
Unless otherwise stated, only reagents that are confirmed to be superior or superior or above are used in the analysis.
4.1 Water, first-grade water specified in GB/T 6682.
4.2 Sodium carbonate and borax.
4.3 Hydrochloric acid: density 1.19 g/mL.
4.4 Hydrochloric acid solution (1 + 1): Take hydrochloric acid (4.3) and water; dilute it 1:1 in volume ratio.
4.5 Hydrofluoric acid: Density 1.15 g/mL.
4.6 Sulfuric acid: Density 1.84 g/mL.
4.7 Nitric acid: Density 1.41 g/mL.
4.8 Single-element standard stock solution: Each single-element standard stock solution is prepared according to the method specified in GB/T 602, or the national standard solution is directly used, its mass concentration is 1.000 mg/mL.
4.9 ICP-OES calibration standard solution series: The ICP-OES calibration standard solution series is diluted and grouped by single-element standard stock solution. The recommended mass concentrations of each element are shown in Appendix A.
6 Samples
6.3.2 Sodium carbonate borax melting method
6.3.2.1 This method is suitable for the determination of all elements except potassium and sodium in the ICP-OES method.
6.3.2.2 Mix a portion of sample, 1g of sodium carbonate, 1 g of borax into a platinum crucible; cover it. Place it in a muffle furnace; heat it from room temperature to 800 °C at a heating rate of no more than 10 °C/min; then heat it to 1000 °C at a heating rate of no more than 5 °C/min; keep it in heat for 30 minutes; take it out with the furnace to cool below 100 °C.
6.3.2.3 After the platinum crucible is cooled to room temperature, add 20 mL ~ 25 mL of water; soak until the frit is loose; transfer to a 250 mL beaker. Add 10 mL of hydrochloric acid solution (1 + 1) in a total amount of 10 mL to the platinum crucible and beaker; rinse the wall of the platinum crucible with water and cover, until there is no residue; heat and boil until all the salts dissolve; cool to room temperature. Transfer the solution into a 100 mL volumetric flask; wash the platinum crucible and cap with water; transfer the wash solution into the volumetric flask; dilute it with water to the marking line; shake it well to prepare for testing.
6.3.3 Pressurized acid dissolution method
6.3.3.1 This method is suitable for the determination of all elements tested by ICP-MS method.
6.3.3.2 Place a portion of the sample in a polytetrafluoroethylene inner tank; add 5 mL of hydrofluoric acid and 8 mL of nitric acid; then slowly add 5 mL of sulfuric acid.
6.3.3.3 After covering the inner cover, put it in the stainless steel jacket; cover the outer cover; tighten the center screw; put it in an electric oven at 240 °C for 16 hours. After cooling, unscrew the center screw; open the outer tank; remove the inner tank; transfer the solution to the platinum evaporation dish; clean the inner tank with deionized water three times; add the washing liquid to the evaporation dish. Place the platinum dish on the electric stove; heat it until no white sulfuric acid smoke appears. After cooling, add 5 mL of nitric acid and a small amount of water. After heating and dissolving, transfer the residue into a 25 mL volumetric flask; wash the evaporation dish 3 times; add the washing solution to the volumetric flask; use water to dilute it to the mark.
6.4 Blank solution
Take the same amount of all reagents as 6.3.2 and 6.3.3, but do not add samples.
7 Test steps
7.1 Calibration curve
7.1.1 ICP-OES method
According to the ICP-OES instrument instructions, the recommended working conditions and the wavelength of the spectral line analysis for each element (see Appendix A), ignite the plasma torch flame. After the torch flame is stabilized, the spectral intensity of the mixed standard series solution (recommended in Appendix A) is sequentially measured on ICP-OES; the intensity of each element is used as the dependent variable; the concentration of the element is used as the independent variable to perform linear regression, to draw the correction curve; the intercept (a), slope (b), linear correlation coefficient (R2) are calculated. If the linear correlation coefficient (R2) is less than 0.999, re-draw the calibration curve.
7.1.2 ICP-MS method
According to the ICP-MS instrument instructions, the recommended working conditions, the mass of each element (see Appendix A), ignite the plasma torch flame.
After the torch flame is stabilized, the mass intensity of the mixed standard series solution (recommended in Appendix A) is sequentially determined on ICP-MS. The intensity of each element's mass number is used as the dependent variable; the concentration of the element is used as the independent variable to perform linear regression to draw the correction curve; the intercept (a), slope (b), linear correlation coefficient (R2) are calculated. If the linear correlation coefficient (R2) is less than 0.995, re-draw the calibration curve.
7.2 Blank test
The blank test shall be carried out in parallel with the test (7.3) and the same steps shall be taken.
7.3 Test
Four tests are performed in parallel.
According to the instrument conditions set in 7.1, the spectral intensity of each measured element in the sample solution (6.3) is measured; the concentration of each measured element is calculated from the calibration curve.
If the concentration of the element being measured exceeds the maximum concentration value of the standard solution, refer to Appendix A to prepare a mixed standard solution with a maximum concentration value slightly higher than the concentration value of the element being measured; repeat the operation steps 7.1 ~ 7.3. […]
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Similar standards
How to Download GB/T 37254-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 602-2026 — Chemical reagent - Preparation of standard solutions for impurity determination
GB/T 6020-2008 — Butadiene for industrial use -- Determination of tert-butyl-catechol (TBC)
GB/T 6022-2008 — Butadiene for industrial use - Determination of oxygen in gaseous phase above liquid butadiene
Secure payment via Stripe
Payments accepted
GB/T 37254-2018
$125.00