GB/T 6020-2008Butadiene for industrial use -- Determination of tert-butyl-catechol (TBC) (English PDF)
工业用丁二烯中特丁基邻苯二酚(TBC)的测定
This is a limited preview
Buy now to download the full PDF (6 pages)
Need quotation for your management?
Get a formal quotation for GB/T 6020-2008 in 30 minutes.
Issued by
Standardization Administration of China
Level / Type
National · Recommended
Issue date
June 19, 2008
Implementation date
February 1, 2009
Scope
GB/T 6020-2008 is the English-translated version of 工业用丁二烯中特丁基邻苯二酚(TBC)的测定.
GB/T 6020-2008 — 1.1 standard provides industry with tert - butyl catechol [ie, 4- (1,1-dimethyl-ethyl) -1,2-hydroquinone] measured spectral Spectrophotometry and high performance liquid chromatography.
This standard applies spectrophotometric measurement range of 1mg/kg ~ 300mg/kg, high performance liquid chromatography Spectroscopy measurement range applies to 1mg/kg ~ 250mg/kg.
1.2 This standard is not intended to illustrate its use of all safety-related issues. Therefore, the user has the responsibility to take appropriate safety and prevention Protective measures to ensure compliance with the provisions of the relevant national regulations.
Found what you need?
Document preview — GB/T 6020-2008
National Standard of the People's Republic of China
- ICS
- 71.080.10
- Classification
- G 15
- Replacing
- GB/T 6020-1999; GB/T 12702-1999
Issued by: Standardization Administration of China
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Spectrophotometry
- 3.1 Method summary
- 3.2 Reagents and materials
- 3.3 Instrument
Foreword
This revised standard adopts ASTMD1157:1991 (2004) "Determination of light hydrocarbons in t-butyl catechol (TBC) standard Standard Test Method "(in English), this Standard and structural differences ASTMD1157 in Appendix A.
This standard ASTMD1157:1991 (2004) of the main differences are.
--- Increased liquid chromatography;
--- Measured by the scope of ASTMD1157 prescribed 50mg/kg ~ 500mg/kg to 1mg/kg ~ 300mg/kg;
--- Calibration curve TBC directly to the quality of the abscissa;
--- Introduction of density in the results calculation.
This standard replaces GB/T 6020-1999 "industrial use of tert - butyl catechol (TBC) spectrophotometric determination" and GB/T 12702-1999 "industrial use of tert - butyl catechol (TBC) High performance liquid chromatography." this standard spectrometry and GB/T 6020-1999 The main differences are as follows.
--- The name was changed to "industrial use of tert - butyl catechol (TBC) Measurement";
--- The measurement process of the reference solution for the reunification of distilled water.
This standard HPLC and GB/T 12702-1999 main differences are as follows.
--- The name was changed to "industrial use of tert - butyl catechol (TBC) Measurement";
--- Chromatographic conditions in the original specifications and particle size column has been modified.
Appendix A of this standard is an informative annex.
The standard proposed by China Petroleum and Chemical Corporation.
This standard by the National Standardization Technical Committee Petrochemical Chemical Club (SAC/TC63/SC4) centralized.
This standard was drafted. China Petroleum & Chemical Corporation Shanghai Research Institute of Petrochemical.
1 Scope
1.1 standard provides industry with tert - butyl catechol [ie, 4- (1,1-dimethyl-ethyl) -1,2-hydroquinone] measured spectral Spectrophotometry and high performance liquid chromatography. This standard applies spectrophotometric measurement range of 1mg/kg ~ 300mg/kg, high performance liquid chromatography Spectroscopy measurement range applies to 1mg/kg ~ 250mg/kg.
1.2 This standard is not intended to illustrate its use of all safety-related issues. Therefore, the user has the responsibility to take appropriate safety and prevention Protective measures to ensure compliance with the provisions of the relevant national regulations.
2 Normative references
The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequently Some amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Study whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.
GB/T 8170 numerical rounding rules GB/T 6682 analytical laboratory use specifications and test methods (GB/T 6682-2008, ISO 3639. 1987, MOD) GB/T 13290 Industrial liquid propylene and butadiene sampling method
3 Spectrophotometry
3.1 Method summary
Butadiene After evaporation, the remaining residue was dissolved with water and an excess of ferric chloride. At 425nm wavelength, with a spectrophotometer Yellow complex was measured by absorbance and the calibration curve for determination of the content of TBC.
3.2 Reagents and materials
The method used reagents were analytical grade, third grade water as the water requirements of GB/T 6682 regulations.
3.2.1 Ethanol. 95% (volume fraction).
3.2.2 hydrochloric acid (density 1.19g/mL).
3.2.3 ferric chloride solution. Weigh 20.0g of ferric chloride (FeCl3 · 6H2O), with 95% ethanol (3.2.1) dissolved moved 1000mL volumetric flask, was added 9.2mL of hydrochloric acid (3.2.2), with 95% ethanol diluted to the mark.
3.2.4 t-butyl catechol (TBC) standard solution.
TBC standard solution 3.2.4.1 6.7mg/mL for. Weigh 0.67gTBC (accurate to 0.0001g), was dissolved in ethanol 10mL95% , And transferred to 100mL volumetric flask, dilute with water to the mark. This solution is unstable and must be formulated immediately prior to use.
3.2.4.2 0.67mg/TBC mL of the standard solution. A standard solution TBC 6.7mg/mL of the diluted 10-fold with water, and mix. this Unstable solution shall be formulated immediately prior to use.
Note. TBC potentially harmful, can cause skin irritation or burns, it can be absorbed through the skin and may cause harm to the respiratory system, swallowing may cause fatal harm retropharyngeal. Avoid contact with the eyes should be, otherwise it will burn eye tissue damage eyesight. Should pay attention to ventilation, should be stored Flammable liquids stored in the area.
3.3 Instrument
3.3.1 Spectrophotometer. with 1cm absorption cell.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 6 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 8170Rules of rounding off for numerical values & expression and judgement of limiting values
- GB/T 6682Water for analytical laboratory use - Specification and test methods
- GB/T 6682-2008Water for analytical laboratory use - Specification and test methods
- GB/T 13290Propylene and butadiene for industrial use -- Sampling in the liquid phase
ISO 3639
How to Download GB/T 6020-2008
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 13290-2014 — Propylene and butadiene for industrial use -- Sampling in the liquid phase
GB/T 6682-2008 — Water for analytical laboratory use - Specification and test methods
GB/T 8170-2008 — Rules of rounding off for numerical values & expression and judgement of limiting values
Secure payment via Stripe