GB/T 36490-2018Wind turbines—Technical specification of lightning protection system inspection (English PDF)
风力发电机组 防雷装置检测技术规范
This is a limited preview
Buy now to download the full PDF (17 pages)
Need quotation for your management?
Get a formal quotation for GB/T 36490-2018 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
July 13, 2018
Implementation date
February 1, 2019
Scope
GB/T 36490-2018 is the English-translated version of 风力发电机组 防雷装置检测技术规范.
GB/T 36490-2018 sets out how the lightning protection systems of wind turbines are inspected.
It specifies the inspection items; general requirements on the basis of inspection, the testing equipment, the inspection period and the procedure; and the requirements and methods for inspecting blade lightning protection, nacelle lightning protection, the grounding device, equipotential bonding and surge protective devices (SPD).
Informative annexes give the main performance of some test instruments, the collation of test data and a method for measuring the grounding resistance of a unit.
It applies to the inspection of lightning protection on onshore wind turbines of 600 kW and above, and references GB/T 33629-2017 on wind turbine lightning protection. It was issued on 13 July 2018 and has applied since 1 February 2019.
Found what you need?
Document preview — GB/T 36490-2018
National Standard of the People's Republic of China
- ICS
- 27.180
- Classification
- F 11
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Test item
- 5 General requirements
- 5.1 Detection basis
- 5.2 Testing equipment requirements
- 5.3 Detection period
- 5.4 Test Procedure
- 6 Testing requirements and methods
- 6.1 Blade lightning protection device
- 6.2 Cabin lightning protection device
- 6.3 Grounding device
- 6.4 Equipotential device
- 6.5 Surge Protector (SPD)
- Appendix A (informative) Main performance and parameter indicators of some testing instruments
- Appendix B (informative appendix) Test data collation
- Appendix C (informative appendix) Unit grounding resistance measurement method
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
1 Scope
This standard specifies the testing procedures, testing items, testing requirements, testing methods, and methods for lightning protection devices for wind turbines (hereinafter referred to as units). Detection cycle and inspection data collation.
This standard is applicable to the lightning protection device detection of onshore units of 600kW and above.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2900.53 Electrotechnical terminology wind turbine
GB/T 16895.22-2004 Electrical installations of buildings - Part 5-53. Selection and installation of electrical equipment - isolation, switching and control Equipment Section 534. Overvoltage Protection Appliances
GB/T 18802.1 Low-voltage surge protectors (SPD) Part 1. Performance requirements and test for surge protectors Test method
GB/T 18802.21 Low voltage surge protectors - Part 21. Surge protectors (SPD) performance requirements for telecommunications and signal networks experiment method
GB/T 21431-2015 Building lightning protection device testing technical specifications
GB/T 33629-2017 wind turbine lightning protection
3 Terms and definitions
The following terms and definitions as defined in GB/T 2900.53 apply to this document.
3.1 Lightning protection device
The whole device for protecting the lightning effect of a certain space, which is composed of an external lightning protection device and an internal lightning protection device.
3.2 External lightning protection device
It consists of a lightning receptor, a down conductor and a grounding device. It is mainly used to protect the lightning protection device against lightning.
The external lightning protection device in this standard refers to the lightning protection system consisting of the blade lightning receptor, the cabin lightning receptor, the down conductor, and the grounding device.
3.3 Internal lightning protection device
In addition to external lightning protection devices, all other additional facilities are internal lightning protection devices, mainly used to reduce and protect lightning currents. The electromagnetic effect generated in the space.
3.4 Surge protector
A device for limiting transient overvoltages and venting corresponding transient overcurrents that contains at least one nonlinear component.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2900.53Electrotechnical terminology -- Wind turbine generator systems
- GB/T 16895.22-2004Low-voltage electrical installations - Part 5-53: Selection and erection of electrical equipment - Devices for protection for safety, isolation, switching, control and monitoring
- GB/T 18802.21Low-voltage surge protective devices -- Part 21: Surge protective devices connected to telecommunications and signaling networks -- Performance requirements and testing methods
- GB/T 21431-2015Technical specification for inspection of lightning protection systems of buildings
- GB/T 33629-2017Wind energy generation systems - Lightning protection
GB/T 18802.1
Similar standards
How to Download GB/T 36490-2018
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 18802.11-2020 — Low-voltage surge protective devices (SPD) - Part 11: Surge protective devices connected to low-voltage power systems - Requirements and test methods
GB/T 18802.12-2024 — Low-voltage surge protective device (SPD) - Part 12: Surge protective devices connected to low-voltage power systems - Selection and application principles
GB/T 18802.21-2016 — Low-voltage surge protective devices -- Part 21: Surge protective devices connected to telecommunications and signaling networks -- Performance requirements and testing methods
Secure payment via Stripe
Payments accepted
GB/T 36490-2018