Valid

GB/T 18802.12-2024Low-voltage surge protective device (SPD) - Part 12: Surge protective devices connected to low-voltage power systems - Selection and application principles (English PDF)

Preview PDF

This is a limited preview

Buy now to download the full PDF (142 pages)

Need quotation for your management?

Get a formal quotation for GB/T 18802.12-2024 in 30 minutes.

Issued by

State Administration for Market Regulation, China National Standardization Administration

Level / Type

National · Recommended

Issue date

May 28, 2024

Implementation date

September 1, 2024

Scope

GB/T 18802.12-2024 (Low-voltage surge protective device (SPD) - Part 12: Surge protective devices connected to low-voltage power systems - Selection and application principles) is available as an English-translated PDF.

GB/T 18802.12-2024 — This document specifies the selection, operation, installation location and coordination principles of SPDs. This document applies to SPDs connected to circuits and equipment with a rated AC voltage not exceeding 1000V (rms), 50/60Hz.

Some SPDs contain at least one nonlinear element for limiting surge voltage and discharging surge current. NOTE. This document only covers SPDs and not surge protective components (SPCs) integrated into equipment.

Found what you need?

Document preview — GB/T 18802.12-2024

National Standard of the People's Republic of China

ICS
29.240.10
Classification
K 30

Issued by: State Administration for Market Regulation, China National Standardization Administration

Contents

  • Preface
  • Introduction
  • 1 Scope
  • 2 Normative references
  • 3 Terms, definitions and abbreviations
  • 3.1 Terms and Definitions
  • 3.2 List of abbreviations and acronyms in this document (see Table 1 and Table 2)
  • 4 Protection needs 15
  • 5 Protected Systems and Devices
  • 5.1 General Principles
  • 5.2 Low voltage power supply system
  • 5.3 Characteristics of protected equipment
  • 6 Surge protector 18
  • 6.1 Basic functions of SPD
  • 6.2 Supplementary requirements
  • 6.3 SPD classification
  • 6.4 SPD characteristics
  • 6.5 Supplementary information on SPD characteristics
  • 7 Application of SPD in low voltage power supply system
  • 7.1 Overview
  • 7.2 Determine the SPD installation location according to the test category
  • 7.3 SPD protection mode and installation
  • 7.4 Factors that need to be considered when affecting the protection effect of SPD
  • 7.5 Selection of SPD characteristics
  • 7.6 Characteristics of auxiliary devices
  • Appendix A (Informative) Structural changes of this document compared with IEC 61643-12:2020
  • Appendix B (Informative) Main technical differences between this document and IEC 61643-12:2020 and their causes
  • Appendix C (Normative) Typical data and explanation of test procedures for selecting SPD
  • Appendix D (Informative) Examples of the relationship between UC and the system nominal voltage and the relationship between the metal oxide varistor (MOV) UP and

Foreword

This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for standardization work Part 1: Structure and drafting rules for standardization documents" Drafting.

This document is Part 12 of GB/T 18802.GB/T 18802 has been published in the following parts.

--- Low voltage surge protective devices (SPD) Part 11: Performance requirements and test methods for surge protective devices for low voltage power supply systems;

--- Low voltage surge protective devices (SPD) Part 12: Guidelines for the selection and use of surge protective devices for low voltage distribution systems;

--- Low voltage surge protective devices Part 21: Surge protective devices (SPD) for telecommunication and signalling networks Performance requirements and test methods;

--- Low voltage surge protective devices Part 22: Guidelines for the selection and use of surge protective devices for telecommunication and signalling networks;

--- Low voltage surge protective devices Part 31: Performance requirements and test methods for surge protective devices for photovoltaic systems;

--- Low voltage surge protective devices Part 32: Guidelines for the selection and use of surge protective devices for photovoltaic systems;

--- Low voltage surge protective device components Part 311: Performance requirements and test circuits for gas discharge tubes (GDT);

--- Low voltage surge protective device components Part 312: Guidelines for the selection and use of gas discharge tubes (GDTs);

--- Low voltage surge protective device components Part 321: Avalanche breakdown diode (ABD) specification;

--- Low voltage surge protective device components Part 331: Specification for Metal Oxide Varistors (MOV);

--- Low voltage surge protective device components Part 341: Surge suppression thyristor (TSS) specification;

--- Low voltage surge protective device components Part 351: Performance requirements and specifications for surge isolation transformers (SIT) for telecommunication and signalling networks experiment method;

--- Low voltage surge protective device components Part 352: Selection and use of surge isolation transformers (SIT) for telecommunication and signalling networks Guidelines.

This document replaces GB/T 18802.12-2014 "Low voltage surge protective devices (SPD) Part 12: Surge protection devices for low voltage power distribution systems" Guidelines for the selection and use of protective devices.

Compared with GB/T 18802.12-2014, the main technical changes of this document are as follows.

--- Changed the scope (see Chapter 1, Chapter 1 of the 2014 edition);

--- Added terms and definitions "impact voltage rating", "overvoltage category", "effective voltage protection level", "short-circuit SPD", "state "State indicator", "open circuit voltage", "short circuit current of composite wave generator", "(alarm) output terminal", "multi-mode SPD", "total discharge Current", "Reference test voltage", "Rated switching surge current of short-circuit type SPD", "Determine electrical clearance voltage", "Varistor voltage" (See 3.1.43, 3.1.44, 3.1.46, 3.1.47, 3.1.48, 3.1.49, 3.1.50, 3.1.51, 3.1.52, 3.1.53, 3.1.54, 3.1.55, 3.1.56, 3.1.57);

--- Changed the terms and definitions "voltage protection level", "compound wave", "SPD disconnector", "type test", "rated short-circuit current", "overcurrent...compound wave", "compound wave Current protection" (see 3.1.4, 3.1.11, 3.1.15, 3.1.16, 3.1.20, 3.1.45, 2014 edition 3.1.4, 3.1.11, 3.1.16, 3.1.17, 3.1.24, 3.1.38);

--- Deleted the terms and definitions "thermal breakdown", "routine test", "acceptance test" and "insertion loss" (see 3.1.14, 2014 edition 3.1.18, 3.1.19, 3.1.22);

--- Added abbreviations and acronyms "short-circuit current ICW of composite wave generator", "rated short-circuit current ISCCR", "multi-mode SPD Total discharge current ITotal", "Rated switching surge current Itrans of short-circuit type SPD", "TOV application time tT during test" "Probability of equipment damage PSPD" "Effective voltage protection level Up/f" "Specific energy W/R" "Varisto voltage Vv" "Double-fed induction power generation DFIG", "DUT", "Equipotential Bonding Strip EB", "Insulated Gate Bipolar Transistor IGB T", "Lightning Electromagnetic Impact LEMP", "Pulse Width Modulation PWM", "Surge Protection Component SPC", "SPD Special Protection Device SSD" (see 3.2);

--- Deleted the abbreviations and acronyms "impact current peak value Ipeak", "CWG short-circuit current Isc", "limit voltage Um", "high voltage A (Medium voltage, < 50kV) HVA "Zinc Oxide ZnO" (see 3.2 of the 2014 edition);

--- Increased protection requirements (see Chapter 4);

--- Deleted the maximum value diagram of UTOV according to GB/T 16895.10-2010 (see Figure 4 of the 2014 edition);

---Changed the selection of SPD parameters, temporary overvoltage characteristics, Iimp preferred value table, ISCCR. rated short-circuit current, Ifi. rated disconnection Continued flow (see 6.4.2, 6.5.1.2, Table 4, 6.5.5, 5.4.2, 5.5.1.2, Table 2, 5.5.5 of the 2014 edition);

--- Delete the relationship diagram between UP, U0, UC and UCS (see Figure 6 of the 2014 edition);

--- Changed the flow chart of SPD application and the flow chart of SPD selection (see Figure 7, Figure 13, Figure 9, Figure 14 of the 2014 edition);

--- Deleted the fault status (see 6.2.4.2 of the 2014 edition);

---Increased the influence of the internal induced voltage of the device, the voltage protection level, the coordination and separation of the SPD and the expected short-circuit current of the installation location Device information (see 7.4.3, 7.4.5, 7.5.2.4, 7.6.1).

This document is modified to adopt IEC 61643-12:2020 "Low-voltage surge protective devices Part 12: Surge protective devices for low-voltage power supply systems" Guidelines for selection and use.

Compared with IEC 61643-12:2020, this document has a structural adjustment. Appendix A lists the differences between this document and IEC 61643-12.

Comparison table of changes in chapter and article numbers in 2020.

This document has technical differences compared to IEC 61643-12:2020.Appendix B provides the corresponding technical differences and their reasons.

List.

The following editorial changes were made to this document.

--- Deleted E.7, E.8.2, E.8.3, Appendix L and Appendix Q which are not relevant to my country's use;

--- Added notes on grounding of buildings in I.2;

--- Figure I.3 and Figure L.11 have been revised;

--- In reference number F of Figures L.1 to L.4, SSD is added to the backup protector example.

Introduction

0.1 Overview

GB/T 18802 aims to establish the performance requirements, test methods and selection of low-voltage surge protectors and low-voltage surge protector components.

Thirteen parts.

--- Low voltage surge protective devices (SPD) Part 11: Performance requirements and test methods for surge protective devices for low voltage power supply systems;

--- Low voltage surge protective devices (SPD) Part 12: Guidelines for the selection and use of surge protective devices for low voltage distribution systems;

--- Low voltage surge protective devices Part 21: Surge protective devices (SPD) for telecommunication and signalling networks Performance requirements and test methods;

--- Low voltage surge protective devices Part 22: Guidelines for the selection and use of surge protective devices for telecommunication and signalling networks;

--- Low voltage surge protective devices Part 31: Performance requirements and test methods for surge protective devices for photovoltaic systems;

--- Low voltage surge protective devices Part 32: Guidelines for the selection and use of surge protective devices for photovoltaic systems;

--- Low voltage surge protective device components Part 311: Performance requirements and test circuits for gas discharge tubes (GDT);

--- Low voltage surge protective device components Part 312: Guidelines for the selection and use of gas discharge tubes (GDTs);

--- Low voltage surge protective device components Part 321: Avalanche breakdown diode (ABD) specification;

--- Low voltage surge protective device components Part 331: Specification for Metal Oxide Varistors (MOV);

--- Low voltage surge protective device components Part 341: Surge suppression thyristor (TSS) specification;

--- Low voltage surge protective device components Part 351: Performance requirements and specifications for surge isolation transformers (SIT) for telecommunication and signalling networks experiment method;

--- Low voltage surge protective device components Part 352: Selection and use of surge isolation transformers (SIT) for telecommunication and signalling networks Guidelines.

Surge protective devices (SPDs) are used to protect power systems and equipment from various types of surges such as lightning surges and operating surges under specified conditions.

A protective device against damage from overvoltage and surge current.

Select an SPD based on environmental conditions and the acceptable failure rates of the equipment and the SPD.

This document provides users with information on the selection and use of SPDs.

This document refers to GB/T 21714.1~21714.4 and GB/T 16895 (all parts) and is provided for evaluating the use of low voltage systems.

Information on the necessity of SPDs. These standards provide information on the selection and coordination of SPDs, taking into account all environmental conditions in which they are used.

Such as. performance of the equipment and system being protected, insulation level, overvoltage, installation method, SPD installation location, SPD coordination, failure mode and Consequences of equipment damage.

GB/T 21714.2 provides a general method for assessing surge and lightning risks. GB/T 16895.10-2021 provides a A simplified approach to assessing risk in electrical installations.

GB/T 16935 (all parts) provides guidance on product insulation coordination. GB/T 16895 (all parts) provides safety (fire, overcurrent and electric shock) and installation requirements.

GB/T 16895 (all parts) provides direct information to SPD installers. IEC TR62066 provides more information on surge protection.

Scientific background information.

0.2 Instructions for understanding the contents of this document

The following is the organization of the document and provides a summary of the material contained in each chapter and appendix. The main chapters provide a selection and Basic information on SPD elements. Readers who need more detailed information on the information provided in Chapters 4 to 7 can refer to the corresponding appendix.

Chapter 1 sets out the scope of this document.

Chapter 2 lists the normative references in this document where additional information can be found.

Chapter 3 provides definitions used to understand this document.

Chapter 4 is an introduction to risk analysis (considering when the use of an SPD is beneficial).

Chapter 5 introduces the system and equipment parameters related to SPD selection. It also introduces the electrical stresses caused by lightning and the Electrical stress caused by temporary overvoltage and operational overvoltage generated by the power grid itself.

Chapter 6 lists the electrical parameters used in selecting SPD and their related instructions. The data involved in these parameters are in GB/T 18802.11-Given in 2020.

Chapter 7 is the core of this document and describes the relationship between electrical stress from the grid (discussed in Chapter 5) and SPD characteristics (discussed in Chapter 6).

It describes how the installation mode of the SPD affects its protection performance and gives different steps for selecting an SPD, including Coordination issues between multiple SPDs used in the device.

Appendix A gives the structural changes of this document compared with IEC 61643-12:2020.

Appendix B gives the main technical differences between this document and IEC 61643-12:2020 and their reasons.

Appendix C provides the query information and explains the test procedures adopted in GB/T 18802.11-2020.

Appendix D provides an example of the relationship between two important parameters UC and UP for metal oxide (MOV) type SPDs, and also lists

Example of the relationship between UC and grid nominal voltage.

Appendix E supplements the information on surge voltages in low-voltage systems given in Chapter 5.

Annex F describes the methods used to determine the direct lightning current distribution between different grounding systems.

Annex G describes temporary overvoltages caused by faults in high voltage systems.

Appendix H supplements the information in Chapter 7 regarding coordination principles when multiple SPDs are used in a system.

Appendix I provides additional examples of using this document.

Appendix J supplements Chapter 4 with specific examples of the application of risk analysis.

Appendix K supplements the information on system electrical stress in Chapter 5.

Appendix L supplements the information in Chapter 7 on the application of SPDs in various low-voltage systems.

Annex M discusses the difference between immunity levels and insulation withstand levels for electrical equipment.

Appendix N discusses the coordination issues when the equipment has both signal ports and power ports.

Appendix O provides additional information on the withstand capability of fuses under surge conditions.

Appendix P provides a practical approach to testing system-level immunity.

Annex Q provides guidance for testing SPDs containing multiple components.

Low voltage surge protective devices (SPD) Part 12: Low voltage Guidelines for selection and use of surge protectors for power supply systems

1 Scope

This document specifies the selection, operation, installation location and coordination principles of SPDs.

This document applies to SPDs connected to circuits and equipment with a rated AC voltage not exceeding 1000V (rms), 50/60Hz.

Some SPDs contain at least one nonlinear element for limiting surge voltage and discharging surge current.

NOTE. This document only covers SPDs and not surge protective components (SPCs) integrated into equipment.

2 Normative references

The contents of the following documents constitute the essential clauses of this document through normative references in this document.

For referenced documents without a date, only the version corresponding to that date applies to this document; for referenced documents without a date, the latest version (including all amendments) applies to this document.

GB/T 4208 Degrees of protection provided by enclosures (IP code) (GB/T 4208-2017, IEC 60529:2013, IDT) GB/T 7251 (all parts) Low voltage switchgear and control equipment Note. GB/T 7251.1-2023 Low-voltage switchgear and controlgear Part 1: General (IEC 61439-1:2020, IDT) GB/T 7251.2-2023 Low-voltage switchgear and controlgear Part 2: Power switchgear and controlgear (IEC 61439-2:2020,IDT) GB/T 7251.3-2017 Low-voltage switchgear and controlgear Part 3: Distribution boards operated by general personnel (DBO) (IEC 61439-3:2012,IDT) GB/T 7251.4-2023 Low-voltage switchgear and controlgear Part 4: Particular requirements for construction site complete sets (ACS) (IEC 61439-4:2012,IDT) GB/T 7251.5-2017 Low-voltage switchgear and controlgear Part 5: Public grid power distribution equipment (IEC 61439-5.

2014, IDT)

GB/T 7251.6-2015 Low-voltage switchgear and controlgear Part 6: Busbar trunk system (bus duct) GB/T 7251.7-2015 Low-voltage switchgear and controlgear Part 7: Complete sets of equipment for specific applications - such as docks, camping sites, Market square, electric vehicle charging station (IEC/T S61439-7.2014, IDT) GB/T 7251.8-2020 Low-voltage switchgear and controlgear Part 8: General technical requirements for intelligent complete sets of equipment GB/T 7251.10-2014 Low-voltage switchgear and controlgear Part 10: Guidelines for specifying complete sets of equipment (IEC/T R61439-0.2013,IDT) GB/T 10963.1 Electrical accessories - Circuit breakers for overcurrent protection for household and similar use - Part 1: Circuit breakers for alternating current (GB/T 10963.1-2020,IEC 60898-1:2015,IDT) GB/T 13539 (all parts) Low voltage fuses Note. GB/T 13539.1-2015 Low-voltage fuses Part 1: Basic requirements (IEC 60269-1:2009, IDT) GB/T 13539.2-2015 Low-voltage fuses Part 2: Supplementary requirements for fuses used by full-time personnel (mainly used in industry) Examples of standardized fuse systems A to K (IEC 60269-2:2013, IDT) GB/T 13539.3-2017 Low-voltage fuses Part 3: Supplementary requirements for fuses used by unskilled personnel (mainly for household and similar Standardized fuse system examples A to F (IEC 60269-3:2013, IDT) GB/T 13539.4-2016 Low-voltage fuses Part 4: Supplementary requirements for fuse-links for protection of semiconductor equipment (IEC 60269-4:2012, IDT) GB/T 13539.5-2020 Low-voltage fuses Part 5: Application guide for low-voltage fuses (IEC/T R60269-5.2014, IDT)

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 142 pages — is available in the English PDF.

Referenced standards

Normative references

IEC 60529 · GB/T 7251 · IEC 61439 · IEC 60898 · GB/T 13539 · IEC 60269

How to Download GB/T 18802.12-2024

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
142 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 18802.12-2024

$2,450.00