Valid

GB/T 3521-2023Methods for chemical analysis of graphite (English PDF)

石墨化学分析方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (26 pages)

Need quotation for your management?

Get a formal quotation for GB/T 3521-2023 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 28, 2023

Implementation date

July 1, 2024

Scope

GB/T 3521-2023 is the English-translated version of 石墨化学分析方法.

GB/T 3521-2023 describes how natural graphite products are analysed chemically.

It covers seven determinations - moisture, volatile matter, ash content, fixed carbon content, sulfur content, acid-soluble iron and iron - and for several of them gives more than one route: volatile matter by box-type high-temperature furnace or under nitrogen protection, fixed carbon by the indirect combustion method or by direct determination on a high-frequency infrared carbon and sulfur analyser, and sulfur by potassium iodate titration, combustion titration coulometry or infrared absorption spectrometry.

General stipulations fix the sample size, the drying and weighing conditions, duplicate parallel determinations and the rounding rules of GB/T 8170, and each method states its allowable deviation.

It replaces GB/T 3521-2008, was issued on 28 December 2023 and has applied since 1 July 2024.

Found what you need?

Document preview — GB/T 3521-2023

National Standard of the People's Republic of China

ICS
73.080
Classification
Q 51
Replacing
GB/T 3521-2008

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope5
  • 2 Normative References5
  • 3 Terms and Definitions5
  • 4 General Stipulations5
  • 5 Determination of Moisture6
  • 6 Determination of Volatile Matter7
  • 7 Determination of Ash Content10
  • 8 Determination of Fixed Carbon Content11
  • 9 Determination of Sulfur Content14
  • 10 Determination of Acid-soluble Iron21
  • 11 Determination of Iron Content26

1 Scope

This document describes methods for the analysis of moisture, volatile matter, ash content, fixed carbon content, sulfur content, acid-soluble iron content and iron content of graphite products.

This document is applicable to the chemical analysis of natural graphite products.

2 Normative References

The contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.

GB/T 6679 General Rules for Sampling Solid Chemical Products

GB/T 6682 Water for Analytical Laboratory Use - Specification and Test Methods

GB/T 8170 Rules of Rounding off for Numerical Values & Expression and Judgement of Limiting Values

3 Terms and Definitions

This document does not have terms or definitions that need to be defined.

4 General Stipulations

4.1 Samples for chemical analysis obtained in accordance with the sampling method specified in GB/T 6679 shall be packed in plastic bags or ground-mouth bottles, and the sampling size shall be no less than 50 g.

4.2 Except for moisture determination, all other analysis items shall be analyzed after the specimens are baked to a constant weight at 105 °C ~ 110 °C.

4.3 The weighing of high, medium and low carbon specimens shall be accurate to 0.1 mg, and when constant weight is required, the difference between the two weighing values shall not be greater than 0.3 mg. The weighing of high-purity graphite specimens shall be accurate to 0.02 mg, and when constant weight is required, the difference between the two weighing values shall not be greater than 0.05 mg.

4.4 Each analysis item shall be determined at least twice in parallel. Take the arithmetic mean of two parallel determination results as the analysis result.

4.5 The calculation results of high-purity graphite are rounded to four decimal places in accordance with GB/T 8170, and the calculation results of other items are rounded to two decimal places in accordance with GB/T 8170.

4.6 Unless otherwise stated, the water used in this Method shall not be lower than Grade-3 water specified in GB/T 6682.

4.7 The concentration of a solution is expressed as molar concentration or mass concentration.

Others, such as. (1 + 1), (1 + 2) and (m + n), etc. refer to the ratio of solute volume to water volume. Unless otherwise specified, the solutions used are all aqueous solutions.

4.8 Unless otherwise stated, the reagents used in this Method are only those confirmed to be of analytical purity or guaranteed purity; the reagents used for calibration are only those confirmed to be primary reagents or of spectral purity or high purity; the acid and ammonia water used are only confirmed concentrated acid or concentrated ammonia water.

5 Determination of Moisture

5.1 Instruments, Equipment and Materials

5.1.2 Analytical balance. with an accuracy not lower than 0.1 mg.

5.1.3 Ground-mouth weighing bottle. 20 mL. […]

5.2 Analytical Procedures

5.3 Result Calculation

The mass fraction (w1) of moisture is calculated in accordance with Formula (1).

5.4 Allowable Deviation

The absolute difference between the results of two parallel determinations shall not be greater than 0.05%.

6 Determination of Volatile Matter

6.1 Box-type High-temperature Furnace Method

6.1.1 Method summary

When the specimen is burned at a high temperature, the amount of volatile substance decomposed and escaped is the volatile matter.

6.1.2 Instruments, Equipment and Materials
6.1.3 Analytical procedures

Accurately weigh-take 1 g of specimen, accurate to 0.1 mg, and record it as m2. Evenly lay it on the bottom of the double-covered porcelain crucible with a constant weight. Place the crucible on the crucible holder, put on the double cover, and place it in the box-type high-temperature furnace (constant-temperature zone).

6.1.4 Result calculation

The mass fraction (w2) of volatile matter is calculated in accordance with Formula (2).

6.1.5 Allowable deviation

The allowable deviation of the results of two parallel determinations is shown in Table 1.

6.2 Nitrogen Protection Method

6.2.1 Method summary

When the specimen is placed in a nitrogen flow and burned at a high temperature, the amount of volatile substance decomposed and escaped is the volatile matter.

6.2.2 Instruments, Equipment and Materials

6.2.2.1 Analytical balance. with an accuracy not lower than 0.1 mg.

6.2.2.4 Quartz boat. the sample loading volume is not less than 1 g.

6.2.2.5 Nitogen. high-purity nitrogen (mass fraction. 99.995%) can be used directly; pure nitrogen (mass fraction. 99.9%) needs to be purified before use.

6.2.4 Result calculation

The mass fraction (w3) of volatile matter is calculated in accordance with Formula (3).

6.2.5 Allowable deviation

The allowable deviation of the results of two parallel determinations is shown in Table 2.

7 Determination of Ash Content

7.1 Method Summary

When the specimen is burned at a high temperature, the residue obtained after the graphite oxidation products and volatiles completely escape is ash content.

7.2 Instruments, Equipment and Materials

7.2.1 Analytical balance. with an accuracy not lower than 0.1 mg.

7.2.4 Desiccator. equipped with color-changing silica gel.

7.3 Analytical Procedures

In accordance with the fixed carbon content, accurately weigh-take 1 g ~ 100 g of dried specimen (accurate to 0.1 mg) and record it as m8. Place it in a porcelain ark with a constant weight, put the porcelain ark into the box-type high-temperature furnace.

7.4 Result Calculation

The mass fraction (w4) of ash content is calculated in accordance with Formula (4).

7.5 Allowable Deviation

The allowable deviation of the results of two parallel determinations is shown in Table 3.

8 Determination of Fixed Carbon Content

8.1 Indirect Carbon Determination Method

8.1.1 Method summary

The indirect carbon determination method is also called the combustion method, that is, after measuring the volatile matter and ash content of the specimen, they are subtracted from the total amount, and the difference is the fixed carbon content. This Method is applicable to graphite products with carbon content (mass fraction) greater than 50%.

8.1.2 Result calculation

8.1.2.1 The fixed carbon content (w5) of high, medium and low carbon graphite is calculated in accordance with Formula (5).

8.1.2.2 The fixed carbon content (w6) of high-purity graphite is calculated in accordance with Formula (6).

8.2 Direct Carbon Determination Method

8.2.2 Reagents

8.2.2.1 Hydrochloric acid solution (1 + 1).

8.2.2.2 Iron filing flux. the carbon content (mass fraction) is less than 0.0005%, and the sulfur content (mass fraction) is less than 0.0005%.

8.2.2.3 Tungsten particle flux. the carbon content (mass fraction) is less than 0.0008%, the sulfur content (mass fraction) is less than 0.0005%, and the particle size is 0.35 mm ~ 0.83 mm.

8.2.2.4 Graphite standard sample. graphite mineral composition analysis standard substance, GBW 03118, GBW 03119, GBW 03120.

8.2.2.5 Oxygen. with a purity not less than 99.5%.

8.2.3 Instruments, equipment and materials

8.2.3.1 High-frequency infrared carbon and sulfur analyzer. carbon determination accuracy is not less than 0.0001%.

8.2.3.2 Analytical balance. with an accuracy not lower than 0.1 mg.

8.2.3.6 Desiccator. equipped with color-changing silica gel.

8.2.3.7 Porcelain crucible. […]

8.2.6 Analytical procedures
8.2.6.1 Calibration test

Actuate the instrument and pre-heat for 30 minutes. Adjust the instrument to determine the fixed carbon state. Turn on the oxygen; in accordance with the sample to be determined, select the standard substance and perform system calibration, until the repeatability of the determination results reaches the uncertainty range required by the graphite standard sample. Thus, the system calibration test is completed.

8.2.6.2 Sample test

Add 0.5 g of iron filings flux and 1.5 g of tungsten particle flux into the crucible containing the treated specimen. Place the crucible on the quartz holder, number it, and click the "ANALYZE" button to start sample determination. The analysis time is adjusted in accordance with the CO2 release curve provided by the high-frequency infrared carbon and sulfur analyzer system. After the test is completed, in accordance with the data provided by the instrument, record the determination results.

8.2.7 Allowable deviation

The allowable deviation of the results of two parallel determinations is shown in Table 4.

9 Determination of Sulfur Content

9.1 Potassium Iodate Titration Method

9.1.2 Reagents

9.1.2.1 Hydrochloric acid solution (3 + 197).

9.1.2.2 Potassium iodate (KIO3). primary reagent.

9.1.2.3 Potassium iodide (KI). analytically pure.

9.1.2.4 Soluble starch. analytically pure.

9.1.2.5 Potassium iodate standard solution (0.0888 g/L). accurately weigh-take 0.0888 g of potassium iodate (KIO3) primary reagent and dissolve it in water. Transfer it to a 1,000 mL volumetric flask, dilute to the scale and store it in a brown bottle. 1 mL of this solution is equivalent to containing 0.04 mg of sulfur.

9.1.2.6 Starch-potassium iodide solution. weigh-take 2 g of soluble starch into 50 mL of water and make it into a paste. While stirring, add the paste to 150 mL of boiling water, boil it for 2 minutes. After cooling, add 6 g of potassium iodide (KI) and stir to dissolve it.

9.1.2.7 Sulfur standard sample. national standard substance of coke or coke whose sulfur content is determined using the Eschka method.

9.1.3 Instruments, equipment and materials

9.1.3.1 Analytical balance. with an accuracy not lower than 0.1 mg.

9.1.3.3 Sulfur determination device. see Figure 2.

9.1.3.4 Porcelain boat. the sample loading volume is not less than 1 g.

9.1.4 Analytical procedures

9.1.4.2 Specimen determination. add 2/3 volume of hydrochloric acid solution (3 + 197) into the sulfur determination cup, add 10 mL of starch-potassium iodide solution, and dropwise add potassium iodate standard solution to make the solution in the sulfur determination cup turn light blue. Use the same method to prepare a reference solution for judging the end point. Ventilate for 4 minutes ~ 5 minutes.

9.1.4.3 Determination of correction coefficient. in accordance with the sample content, select a coke standard sample with an appropriate sulfur content; accurately weigh-take 0.1 g ~ 1.0 g of standard sample, accurate to 0.1 mg, and record it as m11. In the burned porcelain boat, follow the subsequent steps in 9.1.4.2.

9.1.5 Result calculation

9.1.5.1 The correction coefficient (F) is calculated in accordance with Formula (7).

9.1.5.2 The sulfur content (w7) is calculated in accordance with Formula (8).

9.1.6 Allowable deviation

The allowable deviation of the results of two parallel determinations is shown in Table 5.

9.2 Combustion Titration Coulometry

9.2.1 Method summary

The specimen is burned and decomposed in the air flow under the action of a catalyst. The sulfur in the specimen generates sulfur oxides and is absorbed by the potassium iodide solution.

The iodine generated by electrolysis of potassium iodide solution is used for oxidative titration.

In accordance with the electricity consumed by electrolysis to generate iodine, calculate the total sulfur content in the specimen.

9.2.2 Reagents

9.2.2.1 Graphite standard sample. graphite mineral composition analysis standard substance, GBW 03118, GBW 03119, GBW 03120.

9.2.2.2 Tungsten trioxide. analytically pure.

9.2.2.3 Sodium hydroxide. analytically pure.

9.2.2.4 Potassium iodide. analytically pure.

9.2.3 Instruments, equipment and materials

9.2.3.1 Analytical balance. with an accuracy not lower than 0.1 mg.

9.2.3.2 Coal sample. with a particle size less than 0.3 mm, not less than 100 mg.

9.2.3.3 Color-changing silica gel.

9.2.3.4 Porcelain boat. bisque or corundum product; the length of the sample-holding part is about 60 mm, and the temperature resistance is greater than 1,200 °C.

9.2.3.5 Coulomb sulfur meter. it mainly consists of the following parts.

a) Tubular high-temperature furnace. it can be heated to above 1,200 °C. […]

9.2.4 Analytical procedures

9.2.4.2 Add 300 mL of electrolyte to the electrolytic cell and turn on the magnetic stirrer.

9.2.4.3 Turn on the electromagnetic pump, adjust the air flow to 1,000 mL/min, and check the air tightness.

9.2.5 Result calculation

The sulfur content (w8) in the specimen is calculated in accordance with Formula (9).

9.2.6 Allowable deviation

The allowable deviation of the results of two parallel determinations is shown in Table 6.

9.3 Infrared Absorption Spectrometry

9.3.1 Method summary

Place the specimen in a resistance furnace, under oxygen flow, burn it at a high temperature.

The sulfur is oxidized into sulfur dioxide gas. Utilize an infrared analyzer and an integration program to determine the total amount of sulfur dioxide generated. The instrument automatically calculates the sulfur content in the graphite.

9.3.2 Instruments, equipment and materials

9.3.2.3 Oxygen. with a purity of 99.5%.

9.3.2.4 Porcelain boat. the sample loading volume is not less than 1 g.

9.3.3 Analytical procedures

9.3.3.2 Blank test. place the empty porcelain boat in the center of the combustion furnace for testing. The test blank value shall not exceed 0.005%. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 26 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 3521

EditionTitleRevisionStatus
GB/T 3521-2023Methods for chemical analysis of graphitecurrent editionCurrent
GB/T 3521-2008Methods for chemical analysis of graphiteprevious editionSuperseded

This page sells the current edition, GB/T 3521-2023. Earlier editions are listed for reference only.

How to Download GB/T 3521-2023

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
26 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 3521-2023

$360.00