Valid

GB/T 34086-2017Energy efficiency metrologies and test methods for access equipments—EPON system (English PDF)

接入设备节能参数和测试方法 EPON系统

Preview PDF

This is a limited preview

Buy now to download the full PDF (22 pages)

Need quotation for your management?

Get a formal quotation for GB/T 34086-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 31, 2017

Implementation date

November 1, 2017

Scope

GB/T 34086-2017 is the English-translated version of 接入设备节能参数和测试方法 EPON系统.

GB/T 34086-2017 is the Chinese standard "Energy efficiency metrologies and test methods for access equipments—EPON system". Its scope clause reads: This standard specifies the EPON central office OLT and customer premise equipment ONU energy-saving parameters, indicators and energy-saving parameters Test Methods.

This standard applies to EPON systems OLT, SFU, HGU and MDU and other equipment. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 34086-2017

National Standard of the People's Republic of China

ICS
33.040.50
Classification
M 42

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Abbreviations
  • 5 EPON device power consumption status
  • 5.1 OLT device power consumption status
  • 5.2 Power Status of SFU/HGU Devices
  • 5.3 MDU device power consumption status
  • 6 OLT energy-saving parameters and test methods
  • 6.1 OLT energy-saving parameters and indicators
  • 6.1.1 Average power consumption of PON port
  • 6.1.2 Energy Efficiency Index
  • 6.2 OLT energy-saving parameters test method
  • 6.2.1 Test Environment
  • 6.2.2 Power Requirements
  • 6.2.3 Test Reference Configuration
  • 6.2.4 Instrument Requirements
  • 6.2.5 Test Procedure
  • 6.2.6 Test data record
  • 7 SFU/HGU energy saving parameters and test methods
  • 7.1 SFU/HGU energy saving parameters and indicators
  • 7.1.1 Total power consumption
  • 7.1.2 Energy Efficiency Index
  • 7.2 SFU/HGU energy saving parameter test method
  • 7.2.1 Test Environment
  • 7.2.2 Power Requirements
  • 7.2.3 Test system and reference point
  • 7.2.4 Instrument Requirements
  • 7.2.5 Test Procedure
  • 7.2.6 Test Data Record
  • 8 MDU energy saving parameters and test methods
  • 8.1 MDU energy-saving parameters and indicators
  • 8.1.1 Box MDU Power Consumption
  • 8.1.2 Power consumption of the card-type MDU
  • 8.1.3 Energy Efficiency Index
  • 8.2 MDU energy saving parameter test method
  • 8.2.1 Test Environment
  • 8.2.2 Power Requirements
  • 8.2.3 Reference Test Configuration
  • 8.2.4 Instrument Requirements
  • 8.2.5 DSL Test Line Reference Model
  • 8.2.6 Test Procedure
  • 8.2.7 Test Data Record
  • Appendix A (informative) SFU/HGU device power consumption limit value calculation example
  • Appendix B (Informative) Integrated evaluation of energy efficiency of the card-type MDU equipment
  • Appendix C (informative) EPON energy-saving technology

1 Scope

This standard specifies the EPON central office OLT and customer premise equipment ONU energy-saving parameters, indicators and energy-saving parameters

Test Methods.

This standard applies to EPON systems OLT, SFU, HGU and MDU and other equipment.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version applies to this article

Pieces. For undated references, the latest edition (including all amendments) applies to this document.

GB/T 28519 communication products energy consumption test methods General

GB/T 29229 Ethernet-based passive optical network (EPON) technical requirements

YD/T 322 copper polyolefin insulated aluminum composite sheathing city communication cable

YD/T 2278 Access Network Equipment Test Method The second generation very high speed digital subscriber line (VDSL2)

IEEE802.11ac Information technology IEEE standard communication and information exchange between systems Local and metropolitan area network special requirements

Part 11. Wireless LAN Medium Access Control (MAC) and Physical Layer (PHY) Specification Amendments 4. Operates in Bands below 6 GHz

Extremely high throughput enhancements [IEEE standard for Information technology-Telecommunications and information exchangebetweensystems-Localalandmetropolitanareanetworks-Specificrequirements-Part 11.

WirelessLANMediumAccessControl (MAC) and PhysicalLayer (PHY) specifications-Amendment

4. Enhancementsforveryhighthroughputforoperationinbandsbelow6GHz]

IEEE802.11n Information Technology IEEE standard system for communication and exchange of information Local and metropolitan area network special requirements

Part 11. Wireless Media Access Control (MAC) and Physical Layer (PHY) Specification Amendments 5. High-throughput Enhancement [IEEE standard

Informationtechnology-Telecommunications and information exchange between systems-Localand metropolitanareanetwork-Specificrequirements-Part 11.WirelessLAN Medium AccessControl (MAC) and PhysicalLayer (PHY) specifications-Amendment5.Enhancementsforhigherthroughput]

3 Terms and definitions

The following terms and definitions apply to this document.

3.1 Powerconsumption

Equipment in the specified conditions of normal operation of the power input power.

3.2 Energy-saving parameters

Equipment energy classification based on, including power consumption, energy efficiency and supporting parameters, including power consumption and energy efficiency is the most important basis for energy-saving classification.

3.3 Powerconsumptionlimit

The minimum power consumption of a device or device component.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 22 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 34086-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
22 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 34086-2017

$385.00