Valid

GB/T 33957-2017Methods of determination and calculation of heat balance in heat treatment furnace (English PDF)

热处理炉热平衡测试与计算方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (20 pages)

Need quotation for your management?

Get a formal quotation for GB/T 33957-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 12, 2017

Implementation date

April 1, 2018

Scope

GB/T 33957-2017 is the English-translated version of 热处理炉热平衡测试与计算方法.

GB/T 33957-2017 sets out how the heat balance of a heat treatment furnace is measured and calculated.

It fixes the basis of the test and the calculation, the description of the equipment and of the furnace, the record of recent production, the preparation for the test, the test steps, the content of the test and the places and methods of measurement, the calculation methods, and the main content of the heat balance test report.

It applies to the heat treatment furnaces of the steel industry fired with gaseous or liquid fuel, and other industries may use it for reference.

The reference temperature is the average ambient temperature within 1 m of the furnace wall; the low calorific value of the wet gas is used for gaseous fuel and the low calorific value as received for liquid fuel; the balance is normally drawn for the furnace, and for the whole furnace including the waste heat recovery device where one is fitted.

For an intermittent furnace the test lasts one heating cycle, from the start of heating to the complete stop of the fuel supply, while a continuous furnace is tested under continuous conditions at least twice for not less than 2 h each time, and the result is expressed as the heat consumed per tonne of charge in kJ/t.

It cites GB/T 476, GB/T 1884, GB/T 1885, GB/T 17040 and SH/T 0172, along with the methods for the calorific value and the ash content of petroleum products and for moisture in chemical products by loss on drying. It was issued on 12 July 2017 and has applied since 1 April 2018.

Found what you need?

Document preview — GB/T 33957-2017

National Standard of the People's Republic of China

ICS
77.010
Classification
H 04

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword
  • 1 Scope
  • 2 Normative reference documents
  • 3 Thermal balance test and calculation basis

Foreword

This standard is drafted in accordance with the rules given in GB/T 1.1-2009.

1 Scope

This standard specifies the heat treatment furnace heat balance test calculation basis, equipment and furnace profiles, the recent production of the furnace, test preparation, testing Steps, test content, location and methods, calculation methods, thermal balance test report the main content.

This standard applies to the steel industry using gas or liquid fuel heat treatment furnace heat balance test and calculation, other industries heat treatment furnace can be Refer to use.

2 Normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this document. For undated references, the latest edition (including all modifications) applies to this document.

Determination of calorific value of petroleum products

GB/T 476 Determination of carbon and hydrogen in coal

Petroleum products - Determination of ash content

GB/T 1884 Determination of density of crude oil and liquid petroleum products - Laboratory method (density meter method)

GB/T 1885 Oil Meter

General method for determination of moisture in chemical products - Drying reduction method

GB/T 17040 Determination of sulfur content in petroleum and petroleum products - Energy dispersive X-ray fluorescence spectroscopy

SH/T 0172 Determination of sulfur content of petroleum products (high temperature method)

3 Thermal balance test and calculation basis

3.1 Reference temperature

Using the average temperature of the environment, that is, the average ambient temperature of the heat treatment furnace within 1 m from the furnace wall.

3.2 Fuel calorific value

The low (bit) calorific value of the wet gas is used for the gaseous fuel, and the low (bit) calorific value is received for the liquid fuel.

3.3 Thermal balance test range

According to the test requirements, generally do the furnace heat balance, if the waste heat recovery device is the whole furnace (including waste heat recovery device).

3.4 Heat balance test time

The test time for the intermittent heat treatment furnace is a heating cycle, i.e., from the start of heating to the complete stop of the supply of fuel. On the continuous Type heat treatment furnace should be in continuous conditions for continuous testing, the general should be tested more than 2 times, each time not less than 2h.

3.5 Heat balance calculation unit

The amount of heat consumed per ton of furnace material is calculated as kJ/t.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 20 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 33957-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
20 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 33957-2017