Valid

GB/T 33646-2017Determination of the ester compounds in motor rasoline—Gas chromatography (English PDF)

车用汽油中酯类化合物的测定 气相色谱法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 33646-2017 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

May 12, 2017

Implementation date

December 1, 2017

Scope

GB/T 33646-2017 is the English-translated version of 车用汽油中酯类化合物的测定 气相色谱法.

GB/T 33646-2017 is the Chinese national gas chromatographic method for measuring the ester compounds in motor gasoline, namely ethyl acetate, sec-butyl acetate and dimethyl carbonate.

It sets out the summary of the method, the reagents and materials, the apparatus, the sampling, the test procedures, the calculation of the result, the precision, the quality assurance and control, and the test report, with a normative appendix on setting up the valve blowback column system and an informative appendix of chromatograms.

It applies to contents from 50 mg/L to 2 000 mg/L; outside that range the method can still be used, but its precision has not been investigated. It does not apply to alcohol-containing gasoline, and it warns that some alcohols and ketones can interfere. Issued on 12 May 2017, it has applied since 1 December 2017.

Found what you need?

Document preview — GB/T 33646-2017

National Standard of the People's Republic of China

ICS
75.160.20
Classification
E 31

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • Introduction4
  • 1 Scope5
  • 2 Normative References5
  • 3 Terms and Definitions6
  • 4 Method Summary6
  • 5 Reagents and Materials6
  • 6 Apparatus7
  • 7 Sampling8
  • 8 Test Procedures8
  • 9 Result Calculation9
  • 10 Precision10
  • 11 Quality Assurance and Control10
  • 12 Test Report11
  • Appendix A (Normative) Establishment of Valve Blowback System and Instrument Parameters12
  • Appendix B (Informative) Chromatogram of Ester Compounds in Motor Gasoline15

Foreword

This Standard was drafted as per the rules specified in GB/T 1.1-2009.

1 Scope

This Standard specifies the determination method of ester compounds (ethyl acetate, sec-butyl acetate, dimethyl carbonate) in the motor gasoline.

This Standard is applicable to determine the motor gasoline, ester compounds with concentration of 50mg/L ~ 2000mg/L; this Method can also determine beyond such content range; however, the precision is not investigated.

This Standard is not applicable to alcohol-containing gasoline; Certain alcoholic compounds (such as methanol, ethanol, tert-amyl alcohol, and sec-butanol) and ketone compounds (such as acetone and butanone) may interfere the determination of ester compounds.

2 Normative References

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) are applicable to this document.

GB/T 1884 Crude Petroleum and Liquid Petroleum Products - Laboratory Determination of Density - Hydrometer Method

GB/T 1885 Petroleum Measurement Tables

GB/T 4756 Method for Manual Sampling of Petroleum Liquids

GB/T 6683 Petroleum Products - Determination of Precision Data in relation to Methods of Test

6 Apparatus

6.4 Electronic balance. accurate to 0.0001g.

6.5 Volumetric flask. 100mL.

6.6 Sample flask. small glass flask covered with gland or threaded buckle cap, and there is a rubber gasket with polytetrafluoroethylene outer surface in the cap.

6.7 Pipette. 0.5mL, 1.0mL, 2.0mL, 5.0mL.

7 Sampling

7.1 Sampling shall be performed as per GB/T 4756 or other equivalent method.

7.2 Since the laboratory receives the sample, the original container shall be cooled and stored at 0°C~5°C before sampling of any sub-samples.

7.3 If necessary, transfer the cooling sample into the pressure-sealed container, store at 0°C~5°C till analysis is required.

8 Test Procedures

8.1 Gas chromatographic conditions

If different instruments are used, then the optimal analysis conditions may be different; thus, it is impossible to give the general parameters for the gas chromatographic analysis. The setting parameters shall ensure the to-be-tested components to be separated and tested effectively. The parameters given in Appendix A are proven to be feasible.

8.2 Sample injection

Directly take about 1.5mL of sample and place it into 2.0mL sample flask (6.6); manually or take autosampler to inject 1.0µL specimen into gas chromatograph (6.1); perform the chromatographic analysis according to the optimized method conditions.

If the content of ester compounds in the sample exceeds the test range specified in Clause 1, the sample shall be suitably diluted (for instance, isooctane - xylene solution with volume ratio of 5:1).

8.3 Qualitative analysis

Test the standard working solution (5.5) and specimen under the same instrument analysis conditions; perform the qualitative analysis according to the retention time of ester compounds chromatographic peak. The reference retention time of 3 kinds of ester compounds can refer to Appendix B.

Appendix A (Normative) Establishment of Valve Blowback System and Instrument Parameters

A.1 Establishment of valve blowback column system

A.1.1 Adjust the valve to the positive blow position (1 in Figure A.1); adjust the flowrate to control Valve A, so that the flowrate can reach the setting value in Table A.1. Measure the flowrate on the detector exit sample side.

A.1.2 Adjust the valve to the blowback position (2 in Figure A.1); measure the flowrate on the detector exit sample side. If compared with flowrate in Table A.1, the flowrate changes; adjust the flowrate control valve B, so that the flowrate is changed within ±1mL/min.

A.1.3 Switch the valve from the positive blow position to the blowback position for several times; observe the baseline; The change in pressure caused by initially switching of the valve shall not generate the change or drift of the baseline. If baseline changes, slightly adjust the flow control valve B, so that the baseline is stable.

A.2 Determination of blowback time

Prepare the n-nonane solution containing n-octane with volume ratio of 5%. Under the positive blow state, inject 1µL of such solution into the system. Record the chromatogram until the n-nonane flows out, the recorder pen returns to the baseline.

Measure the time from the sample injection to the recorder pen returns to the baseline between the n-octane and n-nonane peak, in seconds. At this point, the n-octane has flowed out, while the n-nonane has not. Half of such measurement time can be approximated as "blowback time", and shall be slightly adjusted within 30s~60s.

Repeat the above operation including the sample injection, switch to blowback state according to the above determined "blowback time". Then obtain the n-octane chromatogram, while the n-nonane peak is very small or invisible in the chromatogram.

If necessary, do the further test, adjust "blowback time" till all n-octane peaks appear; there is very small or no n-nonane peak. The "blowback time" obtained through actual valve operation is required to be used in all the following calibration and analysis.

A.3 Instrument conditional parameters

When using different instruments, the optimum analysis conditions may be different; so it is impossible to give the general parameters for gas chromatographic analysis. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 33646-2017

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 33646-2017

$115.00