Scope

GB/T 29470-2012 is the English-translated version of 自限温电热片.

GB/T 29470-2012 is the Chinese standard "Self-regulating heating elements". Its scope clause reads: This standard specifies the self-limiting temperature Heaters terms and definitions, classification and models, technical requirements, test methods, inspection rules, marks, packages Loading, transport and storage.

This standard applies to installation in a building ground for the room where the self-limiting temperature electric heating film. Rated voltage is not its single-phase device More than 250V, other devices rated voltage not exceeding 480V.

Other uses of self-limiting temperature heaters can also refer to use. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 29470-2012

National Standard of the People's Republic of China

ICS
29.130
Classification
K 32

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Classification and type
  • 5 Technical requirements
  • 7 Inspection rules
  • 8 signs, packaging, transportation and storage

1 Scope

This standard specifies the self-limiting temperature Heaters terms and definitions, classification and models, technical requirements, test methods, inspection rules, marks, packages

Loading, transport and storage.

This standard applies to installation in a building ground for the room where the self-limiting temperature electric heating film. Rated voltage is not its single-phase device

More than 250V, other devices rated voltage not exceeding 480V. Other uses of self-limiting temperature heaters can also refer to use.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein

Member. For undated references, the latest edition (including any amendments) applies to this document.

GB/T 191-2008 Packaging - Pictorial signs

GB/T 2828.1 Sampling procedures for inspection - Part 1. by acceptance quality limit (AQL) retrieval batch inspection sampling plan

GB/T 2829 periodic inspection Sampling procedures and tables (suitable for process stability test)

GB/T 2900.23-2008 Electrotechnical terminology industrial electric equipment

Part 1 GB 4706.1-2005 Safety of household and similar electrical appliances. General requirements

Particular requirements GB 4706.8 Household and similar electrical appliances - Safety blankets, pads and similar flexible heating appliances

GB/T 5169.5 Fire hazard testing for electric and electronic products - Part 5. Test flames - Needle-flame test methods for confirming test

Test methods and guidelines

GB/T 7287-2008 Test Method for Infrared radiant heaters

GB/T 17627.1-1998 high voltage test techniques for low voltage equipment Part I. Definitions and testing requirements

3 Terms and Definitions

GB/T 2900.23-2008 defined and the following terms and definitions apply to this document.

3.1 Self-limiting temperature heaters self-regulatingheatingelement

Sheet-like heat generating element by the electrodes, PTC thermistors and electrically insulating sheet composed of laminated.

3.2 Steady state steadilyworkingcondition

Under specified test conditions, self-limiting temperature electric heating sheet surface temperature fluctuation range at any point does not exceed 2 °C/h working condition,

It called steady state.

3.3 Operating temperature

Under test conditions, when the rated voltage energized to steady state operation, self-limiting temperature average surface temperature of the heaters.

3.4 Heating time

Under test conditions, the rated voltage is energized, the surface temperature is raised to 90% of the time required for steady state temperature.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 29470-2012

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 29470-2012

$255.00