GB/T 27602-2011Measurement of radiofrequency sensitivity for industrial electric detonator (English PDF)
工业电雷管射频感度测定
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 27602-2011 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 5, 2011
Implementation date
May 1, 2012
Scope
GB/T 27602-2011 is the English-translated version of 工业电雷管射频感度测定.
GB/T 27602-2011 is the Chinese standard "Measurement of radiofrequency sensitivity for industrial electric detonator".
Its scope clause reads: This standard specifies the principle, instruments, equipment and apparatus, test conditions, specimen preparation, test procedures for determining the radio frequency sensitivity of industrial electric detonators.
This standard is applicable to determining the sensitivity of industrial electric detonators to frequencies (continuous wave) of 0.3 GHz ~ 18 GHz. Civil electric detonators for other applications may refer to this standard.
Its clauses include principle; instruments, equipment, apparatus; test conditions; specimen preparation; test procedure.
Found what you need?
Document preview — GB/T 27602-2011
National Standard of the People's Republic of China
- ICS
- 71.100.30
- Classification
- G 89
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword3
- 1 Scope4
- 2 Normative references4
- 3 Principle4
- 4 Instruments, equipment, apparatus5
- 5 Test conditions6
- 6 Specimen preparation6
- 7 Test procedure7
- detonator10
1 Scope
This standard specifies the principle, instruments, equipment and apparatus, test conditions, specimen preparation, test procedures for determining the radio frequency sensitivity of industrial electric detonators.
This standard is applicable to determining the sensitivity of industrial electric detonators to frequencies (continuous wave) of 0.3 GHz ~ 18 GHz. Civil electric detonators for other applications may refer to this standard.
2 Normative references
The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document;
for the undated documents, only the latest version (including all the amendments) is applicable to this standard.
GB 8031 Industrial electric detonators
GB/T 13808 Wrought copper and copper alloys - Extruded rods and bars
GB/T 21652 Copper and copper alloy wire
GJB/Z 377A-1994 Mathematical statistical methods for sensitivity testing
3 Principle
In a shielded chamber, an adjustable RF source with adjustable test frequency and output power is used to apply RF power to the industrial electric detonator via a matching device. Basic RF sensitivity tests are used, to determine the firing sensitivity of the industrial electric detonator for different firing modes at different frequencies and basic RF powers. Statistical RF sensitivity tests are used to determine the RF power and its standard deviation at sensitive frequencies and firing modes, or at frequencies of interest and firing modes with 50% firing rates. The firing and non-firing RF powers at given confidence levels and response probabilities are extrapolated. The block diagram of the test system is shown in Figure 1.
4 Instruments, equipment, apparatus
The instruments, equipment, apparatus used shall meet the following requirements:
- Shielded chamber: Suitable for protection at the frequency being tested.
- RF source: Frequency adjustable at 0.3 GHz ~ 18 GHz; output RF power continuously adjustable and suitable for industrial detonator RF sensitivity testing.
- Isolator: Suitable for operation at the frequency being tested.
- Dual-directional coupler: Suitable for operation at the frequency being tested.
- Incident power meter: Measurement power not less than 25 W.
- Reflected power meter: Measurement power not greater than 1 W.
- Coaxial switch: Suitable for operation at the frequency being tested.
- Controller: Test switch switching shall be flexible and reliable.
- Medium power meter: Measurement power not less than 25 W.
- Matching device: Suitable for operation at the frequency being tested.
- Coaxial adapters:
N-50KK, suitable for connection with industrial electric detonators (see Appendix
A);
N-50JJ, suitable for connection with matching devices and N-50KK.
- Explosion-proof device: Suitable for safety testing of the radio frequency sensitivity of industrial electric detonators.
5 Test conditions
5.1 Basic radio frequency sensitivity test
5.1.1 Test location
All instruments, equipment, devices used in the test, except for the controller, shall be placed in a shielded chamber (see Figure 1); the ambient temperature of the test location shall be 16 °C ~ 32 °C; the relative humidity shall not exceed 75%. Actual environmental conditions shall be recorded during the measurement period.
5.1.2 Test frequency
At least six frequency points shall be selected for testing within the frequency range of
0.3 GHz ~ 18 GHz. Unless otherwise specified, six frequency points can be selected:
0.5 GHz, 1.8 GHz, 3.2 GHz, 5.5 GHz, 9.2 GHz, 15.0 GHz.
5.1.3 Test mode
The radio frequency (RF) sensitivity of industrial electric detonators in both foot-to- foot and foot-to-casing firing modes shall be tested.
5.2 Statistical RF sensitivity test
5.2.1 Test location
All instruments, equipment, devices used in the test, except for the controller, shall be placed in a shielded chamber (see Figure 1). The ambient temperature of the test location shall be 16 °C ~ 32 °C; the relative humidity shall not exceed 75%. Actual environmental conditions shall be recorded during the measurement period.
5.2.2 Test frequency
Based on the results of the basic RF sensitivity test, select the most sensitive frequency.
If this cannot be determined, the frequency of greatest interest can be used.
5.2.3 Test mode
Based on the results of the basic RF sensitivity test, select the most sensitive mode. If this cannot be determined, the test shall be conducted according to the test mode specified in 5.1.3.
6 Specimen preparation
6.1 Specimen quantity
6.1.1 Basic RF sensitivity test
Unless otherwise specified, at least 10 industrial electric detonator specimens conforming to GB 8031 shall be tested at each frequency point. Specimens that did not fire in the foot-to-shell firing mode test may be used in the foot-to-foot firing mode test, but a maximum of 5 specimens may be used.
6.1.2 Statistical RF sensitivity test
The number of industrial electric detonator specimens required for the statistical RF sensitivity test shall be determined according to the lifting method specified in GJB/Z 377A-1994.
6.2 Connecting leads
Connect the leads of all specimens according to the firing mode to be tested. For the foot-to-foot firing mode, the leads are the leads of the two bridge wires of the specimen;
for the foot-to-shell firing mode, the leads are the short-circuited leads and the wire connected to the specimen shell (i.e., the connector in Figure A.5). The lead length is (25 ± 0.5) mm; any excess shall be cut off.
6.3 Connection of specimen to N-50KK coaxial adapter
The connection between the specimen and the N-50KK coaxial adapter is detailed in
Appendix A.
7 Test procedure
7.1 Basic RF sensitivity test
7.1.1
Connect the RF sensitivity test system as shown in Figure 1. Turn on the power to all instruments; preheat and adjust according to the instrument instruction manual.
7.1.2
Set the controller's test switch to the power setting. The coaxial switch will then connect to the medium power meter.
7.1.3
Connect the N-50JJ coaxial adapter to the output of the matching device. Connect the other end of the N-50JJ coaxial adapter to the specimen already connected to the N-
50KK coaxial adapter (see Figure A.1); push it into the explosion-proof device.
7.1.4
Turn on the RF source high-voltage switch; select the test frequency; adjust the
RF source output power to 10 mW ~ 20 mW. Set the controller's test switch to the test setting. The coaxial switch will then connect to the matching device.
7.1.5
Adjust the matching device to achieve an incident power to reflected power ratio of 100:1, indicating that the matching is properly adjusted. Remove the test probes of the incident power meter and reflected power meter from the dual directional coupler.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Similar standards
How to Download GB/T 27602-2011
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 10003-2026 — Biaxially oriented polypropylene (BOPP) film
GB/T 10004-2026 — Plastic/Plastic laminated films and pouches for packaging
GB/T 10007-2026 — Rigid cellular plastics - Determination of shear properties
Secure payment via Stripe
Payments accepted
GB/T 27602-2011
$135.00