Valid

GB/T 26868-2011The guide for design and application of high-voltage power filters (English PDF)

高压滤波装置设计与应用导则

Preview PDF

This is a limited preview

Buy now to download the full PDF (33 pages)

Need quotation for your management?

Get a formal quotation for GB/T 26868-2011 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

July 29, 2011

Implementation date

December 1, 2011

Scope

GB/T 26868-2011 is the English-translated version of 高压滤波装置设计与应用导则.

GB/T 26868-2011 is the Chinese standard "The guide for design and application of high-voltage power filters".

Its scope clause reads: This standard defines and classifies high-voltage passive power filters, and specifies the design principles, design basis, design methods, basic contents of application technologies, etc. This standard is applicable to high-voltage passive power filters (hereinafter referred to as filters) with power frequency of 50 Hz and rated voltage from1,000 V (inclusive) to 110 kV (inclusive).

In addition to this guide, the design and application of filters shall also comply with those specified in the current relevant standards and codes of the nation. Its clauses include terms and definitions.

Found what you need?

Document preview — GB/T 26868-2011

National Standard of the People's Republic of China

ICS
31.060.70
Classification
K 42

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword i
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 3.1 Harmonic
  • 3.2 Power
  • 3.3 Filter
  • 3.4 Filter parameters
  • 4 Design principles
  • 4.1 Reliability
  • 4.2 Safety
  • 4.3 Functional requirements
  • 4.4 Flexibility
  • 4.5 Other special requirements
  • 4.6 Economy
  • 5 Design basis
  • 5.1 Design conditions
  • 5.2 Design requirements
  • 6 Design methods
  • 6.1 Determination of filter type
  • 6.2 Wring of filter
  • 6.3 Combination of filtering device
  • 6.4 Determination of reactive compensation capacity
  • 6.5 Calculation of filtering device parameters
  • 6.6 Harmonic simulation of filters
  • 6.7 Calculation and verification of filter element parameters
  • 6.8 Protection of filters
  • 6.9 Filter control
  • 6.10 Selection of main circuit components
  • 7 Application technology
  • 7.1 Test
  • 7.2 Installation and arrangement
  • 7.3 Debugging of filters
  • 7.4 Operation and maintenance
  • Annex A (Informative) Simulation of filters
  • Annex B (Informative) Selection of main circuit components
  • Bibliography

1 Scope

This standard defines and classifies high-voltage passive power filters, and specifies the design principles, design basis, design methods, basic contents of application technologies, etc.

This standard is applicable to high-voltage passive power filters (hereinafter referred to as filters) with power frequency of 50 Hz and rated voltage from1,000 V (inclusive) to 110 kV (inclusive).

In addition to this guide, the design and application of filters shall also comply with those specified in the current relevant standards and codes of the nation.

2 Normative references

The following referenced documents are indispensable for the application of this document. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.

GB 1984 Specification of high-voltage alternating-current circuit-breakers (GB 1984-2003; IEC 62271-100: 2001, MOD)

GB 1985 Specifications for HV AC disconnectors and earthing switches (GB 1985-2004; IEC 62271-102: 2002, MOD)

GB 3906 Alternating-current metal-enclosed switchgear and controlgear for rated voltages above 3.6 kV and up to and including 40.5 kV (GB 3906-2006; IEC 62271-200: 2003, MOD)

GB 4208 Degrees of protection provided by enclosure (IP code) (GB 4208-2008; IEC 60529: 2001, IDT)

GB/T 11022 Common specifications for high-voltage switchgear and controlgear standards (GB/T 11022-1999; eqv IEC 60694: 1996)

GB/T 12325 Power quality - Deviation of supply voltage

GB/T 14549-1993 Quality of electric energy supply - Harmonics in public supply network

GB/T 16927.1 Hign voltsge test techniques - Part 1: General test requirements (GB/T 16927.1-1997; eqv IEC 60060-1: 1989)

GB/T 16927.2 High-voltage test techniques - Part 2: Measuring systems (GB/T 16927.2-1997; eqv IEC 60060-2:1994)

GB 50227 Code for design of installation of shunt capacitors

3 Terms and definitions

For the purposes of this document, the following terms and definitions apply.

3.1 Harmonic

3.1.1 point of common coupling

PCC connection where users access the public supply network

3.1.2 harmonic measurement points

specific points for harmonic measurement of public bus and power lines or user bus and power supply lines and related equipment or devices of the power grid

3.1.3 fundamental component

components with the same frequency as the power frequency of the power grid obtained by carrying out Fourier series decomposition on periodic nonsinusoidal alternating current component

3.1.4 harmonic component

components with the frequency being an integer multiple of the fundamental frequency greater than 1 obtained by carrying out Fourier series decomposition on periodic nonsinusoidal alternating current component

3.1.5 harmonic order

h integer ratio of harmonic frequency to fundamental frequency

3.1.6 total harmonic content

square root value of the amount obtained by subtracting the fundamental component from the whole periodic nonsinusoidal alternating current corresponding to the power frequency of the power grid (harmonic voltage content or harmonic current content) […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 33 pages — is available in the English PDF.

Referenced standards

Similar standards

How to Download GB/T 26868-2011

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
33 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 26868-2011

$485.00