Valid

GB/T 2566-2010Determination of transmittance for low rank coal (English PDF)

低煤阶煤的透光率测定方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 2566-2010 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

September 26, 2010

Implementation date

February 1, 2011

Scope

GB/T 2566-2010 is the English-translated version of 低煤阶煤的透光率测定方法.

GB/T 2566-2010 is the Chinese standard "Determination of transmittance for low rank coal". Its scope clause reads: This Standard specifies the reagents and materials, instruments and equipment used to determine the transmittance of low rank coal, as well as determination procedure, expression and precision of determination results.

This Standard applies to lignite and low rank bituminous coal. Its clauses include method principle; reagents and materials; instruments and apparatuses; determination procedure; expression of determination results; precision.

It was issued by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China on SEPTEMBER 26, 2010 and took effect on FEBRUARY 01, 2011.

Found what you need?

Document preview — GB/T 2566-2010

National Standard of the People's Republic of China

ICS
73.040
Classification
D 21
Replacing
GB/T 2566-1995

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Method principle4
  • 3 Reagents and materials4
  • 4 Instruments and apparatuses5
  • 5 Determination procedure6
  • 6 Expression of determination results7
  • 7 Precision7
  • Annex A (Informative) Potassium dichromate standard series solution8
  • Annex B (Informative) Original record of transmittance determination12

Foreword

This Standard replaces GB/T 2566-1995 "Determination of transmittance for low rank coal".

Compared with GB/T 2566-1995, this Standard has mainly made the following modifications.

- According to the requirements of GB/T 1.1, MODIFY the format of the standard accordingly;

- REORGANIZE relevant clauses of the standard;

- ADD Table A.2 in Annex A;

- ADJUST repeatability and reproducibility values for different transmittance ranges (see Clause 7).

Annex A and Annex B of this Standard are informative annexes.

1 Scope

This Standard specifies the reagents and materials, instruments and equipment used to determine the transmittance of low rank coal, as well as determination procedure, expression and precision of determination results. This Standard applies to lignite and low rank bituminous coal.

2 Method principle

Low rank coal reacts with mixed acid of nitric acid and phosphoric acid under the specified test conditions and produces a colored solution. According to the color depth of the solution, use potassium dichromate solution with different concentrations as the standard, determine the transmittance of the coal sample by visual colorimetry.

3 Reagents and materials

3.1 10 % sulfuric acid (GB/T 625, chemically pure) solution (volume fraction).

3.2 Potassium dichromate (GB/T 642, analytically pure). Before use, it shall be dried at 110 °C ~ 120 °C for 2 h.

3.3 (1 + 9) phosphoric acid (GB/T 1282, chemically pure) solution (volume fraction).

3.4 Nitric acid (GB/T 626, chemically pure). Yellow nitric acid cannot be used.

3.5 Mixed acid. Prepared by mixing 1 volume of nitric acid, 1 volume of phosphoric acid and 9 volumes of distilled water.

3.6 Potassium dichromate preparation solution.

3.7 Potassium dichromate standard series solution

USE 1 mL, 2 mL, 5 mL, or 10 mL straight pipette (or microtiter) with fine marks to pipette the required volume of preparation solution from potassium dichromate preparation solution (3.6.1 and 3.6.2) in sequence, PLACE in 50 mL volumetric flasks, USE 10 % sulfuric acid solution (3.1) to dilute to the mark, to prepare standard series solution, SHAKE well for use. Annex A provides the correspondence between the concentration of the standard solution prepared and the volume of the potassium dichromate preparation solution required.

4 Instruments and apparatuses

4.1 Analytical balance. with a sensitivity of 0.000 2 g.

4.2 Colorimetric tube. 25 mL, internal diameter 17 mm ± 0.5 mm, scaled at 10 mL, with tight stopper.

4.4 Mercury thermometer. The measuring range is 0 °C ~ 100 °C, and the graduation is less than 0.2 °C. It is used after calibration.

4.6 Small glass funnel. The funnel mouth inner diameter is 30 mm, the funnel handle length is about 40 mm, and the inner diameter is 4 mm ~ 5 mm.

4.5 Volumetric flask. 100 mL; Erlenmeyer flask. 100 mL; pipette. 25 mL

Because some samples are prone to generate bubbles with coal powder during heat treatment, it should use special long-neck flasks.

5 Determination procedure

5.1 WEIGH test coal sample for general analysis (require raw coal sample or floating coal sample with ash Ad <= 10 %, but it may use raw coal sample for lignite that is easily argillized in water) equivalent to 1.000 0 g (accurate to 0.000 2 g) of dry ash-free coal, TRANSFER into a dry 100 mL volumetric flask.

5.3 After heating for 90 min, REMOVE the volumetric flask from the water bath and allow it to quickly cool to room temperature. USE (1 + 9) phosphate (3.3) to rinse the small funnel and volumetric flask neck, then ADD (1 + 9) phosphoric acid (3.3) to the volumetric flask to the mark. SHAKE after stoppering.

5.4 After standing for 15 min to 30 min, filter with dry funnel and dense qualitative filter paper. FILTER the filtrate into a dry 100 mL Erlenmeyer flask (it shall take care to prevent extremely fine pulverized coal from diafiltration, otherwise it shall be filtered again), DISCARD a small amount of filtrate that is originally filtered out. After filtration, discard the residue. The filtrate shall be determined for transmittance by visual colorimetry on the same day.

5.5 When performing colorimetric analysis, proceed as follows

6 Expression of determination results

The transmittance (PM) determination result may be read to 1 %. For coal samples with PM less than 16 %, it is filled in as less than 16 % when reporting results.

7 Precision

The precision of transmittance (PM) determination shall comply with the specifications of Table 1.

Annex A (Informative) Potassium dichromate standard series solution

Annex A provides the correspondence between the concentration of the standard solution and the volume of the potassium chromate solution (3.6.1 and 3.6.2) required when preparing 50 mL of potassium dichromate standard series solution.

According to actual work requirements, potassium dichromate standard solution can be prepared according to Table A.1 and Table A.2, respectively. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Similar standards

Editions of GB/T 2566

EditionTitleRevisionStatus
GB/T 2566-2010Determination of transmittance for low rank coalcurrent editionCurrent
GB/T 2566-1995Determination of transmittance for low rank coalprevious editionSuperseded

This page sells the current edition, GB/T 2566-2010. Earlier editions are listed for reference only.

How to Download GB/T 2566-2010

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 2566-2010

$55.00