Valid

GB/T 2514-2008Hydraulic fluid power -- Four-port directional control valves -- Mounting surfaces (English PDF)

液压传动 四油口方向控制阀安装面

Preview PDF

This is a limited preview

Buy now to download the full PDF (7 pages)

Need quotation for your management?

Get a formal quotation for GB/T 2514-2008 in 30 minutes.

Issued by

Standardization Administration of China

Level / Type

National · Recommended

Issue date

February 28, 2008

Implementation date

August 1, 2008

Scope

GB/T 2514-2008 is the English-translated version of 液压传动 四油口方向控制阀安装面.

GB/T 2514-2008 — This standard specifies the hydraulic four - port directional control valve mounting surface dimensions and related data. This standard applies to hydraulic four - port directional control valve and its connecting plate or manifold.

Found what you need?

Document preview — GB/T 2514-2008

National Standard of the People's Republic of China

ICS
23.100.50
Classification
J 20
Replacing
GB/T 8099-1987; GB/T 2514-1993

Issued by: Standardization Administration of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Symbol
  • 5 Tolerance
  • 6 Mounting surface and code size

Foreword

This revised standard adopts ISO 4401:2005 "Hydraulic Four - port directional control valve mounting surface" (in English).

This standard and ISO 4401:2005 technical content is basically the same, only the following minor modifications.

--- Remove introduction of international standards and references;

--- The corresponding reference standards in place of national standards with international standards;

--- Delete all tables on the required pressure "Notes to Table";

--- The figures of "footnote" content into Chapter 7; Chapter 7 title changed to "technical requirements";

--- Delete Table 2, Table 3, Table 8 "NOTE. The backplane connector should consider port seal";

--- Table 9, G1 hole x0 axis position size 138.6 to 147.6.

This standard replaces GB/T 2514-1993 "Hydraulic fluid power - Four - port directional control valve mounting surfaces", GB/T 8099-1987 "hydraulic superimposed Valve mounting surface, "compared with its main changes are as follows.

--- Change the code representation of the mounting surface.

--- The main ports were changed to a maximum diameter 4,6.3,23.4 4.5,7.5,25.

The standard proposed by China Machinery Industry Federation.

This standard by the National Standardization Technical Committee of hydraulic and pneumatic (SAC/TC3) centralized.

1 Scope

This standard specifies the hydraulic four - port directional control valve mounting surface dimensions and related data.

This standard applies to hydraulic four - port directional control valve and its connecting plate or manifold.

2 Normative references

The following documents contain provisions which, through reference in this standard and become the standard terms. For dated references, subsequent Amendments (not including errata content) or revisions do not apply to this standard, however, encourage the parties to the agreement are based on research Whether the latest versions of these documents. For undated reference documents, the latest versions apply to this standard.

GB/T 1031 surface roughness parameters and their values GB/T 1182 General shape and position tolerances, definitions, symbols, indications on drawings (GB/T 1182-1996, eqv ISO 1101.

1996)

GB/T 1800.4-1999 Limits and fits standard tolerance grades and limit deviations for holes and shafts of (eqv ISO 286-2. 1988) GB/T 14043-2005 Hydraulic valve mounting surfaces and cartridge valve cavities identification code (ISO 5783:1995, IDT) GB/T 17446 Fluid power systems and components Terminology (GB/T 17446-1998, idt ISO 5598. 1985)

3 Terms and definitions

GB/T 17446 to determine the terms and definitions apply to this standard.

4 Symbol

4.1 Standard, the following letter symbols.

a) A, B, L, P, T, T1, X, and Y represents a port;

b) F1, F2, F3, F4, F5 and F6 represent a threaded hole;

c) G, G1, G2 represents dowel hole.

4.2 standards adopted in line with the mounting surface Code GB/T 14043-2005 predetermined code rule.

5 Tolerance

5.1 mounting surface (that is, in an area chart crude within dotted line) using the following values.

a) Surface roughness. according to GB/T 1031 regulations, R Rao <=0.8µm;

b) surface flatness. according to GB/T 1182 provides that any 100 × 100mm2 range of 0.01mm;

c) locating pin hole diameter tolerance. according to GB/T 1800.4-1999 prescribed H12.

5.2 starting from the origin of coordinates along the x0 axis and y-axis position of the hole size tolerance as follows.

a) locating pin hole. ± 0.1mm;

b) a threaded hole. ± 0.1mm;

c) Port. ± 0.2mm.

6 Mounting surface and code size

6.1 Main port maximum diameter of 4.5 m1 m1 four-port control valve mounting surface (port Specification code. 02)

a) mounting surface Code. GB/T 2514-02-01-0-2008;

b) dimensions shown in Figure 1, Table 1.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

Cited by

How to Download GB/T 2514-2008

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 2514-2008

$155.00