GB/T 8100.2-2021Mounting surfaces of hydraulic valves - Part 2: Compensated flow-control valves (English PDF)
Also coversGBT8100.2-2021
Open the GB/T 8100.2-2021 preview as PDF
This is a limited preview
Buy now to download the full PDF
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
December 31, 2021
Implementation date
July 1, 2022
Scope
GB/T 8100.2-2021 (Mounting surfaces of hydraulic valves - Part 2: Compensated flow-control valves) is available as an English-translated PDF.
GB/T 8100.2-2021 — This document specifies the dimensions and related data of the speed control valve mounting surface to ensure the interchangeability of use: This document applies to the speed control valve mounting surface commonly used in industrial equipment:
Document preview — GB/T 8100.2-2021
National Standard of the People's Republic of China
- Classification
- J 20
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- foreword
- Introduction
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 symbols
- 5 Tolerance
foreword
This document is in accordance with the provisions of GB/T 1:1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents"
drafted:
This document is part 2 of GB/T 8100 "Hydraulic Valve Mounting Surface": GB/T 8100 has released the following parts:
--- Part 2: Speed control valve;
--- Part 3: Pressure reducing valves, sequence valves, unloading valves, throttle valves and check valves:
This document replaces GB/T 8098-2003 "Hydraulic Transmission Belt Compensated Flow Control Valve Mounting Surface", which is the same as GB/T 8098-2003
Compared to this, the main technical changes are as follows:
--- Changed normative references (see Chapter 2, Chapter 2 of the:2003 edition);
--- Delete the mounting surface with the main port diameter of 28:4mm (see 6:10, 6:11, 7:10, 7:11, Figure 9, Figure 10, Table:2003
17~Table 20);
--- Changed the graphic symbols of the speed control valve (see Table 2, Table 4, Table 6, Table 8, Table 10, Table 12, Table 14, Table 16);
--- Deleted Appendix A (see Appendix A of the:2003 edition):
This document is modified to adopt ISO 6263:2013 "Hydraulic Transmission Belt Compensated Flow Control Valve Mounting Surface":
The technical differences between this document and ISO 6263:2013 and their reasons are as follows:
--- Regarding normative reference documents, this document has made adjustments with technical differences to adapt to the technical conditions of our country and the circumstances of the adjustment:
The situation is reflected in Chapter 2 "Normative References", and the specific adjustments are as follows:
* Replace ISO 1219-1 (see 4:2) with GB/T 786:1 which is equivalent to adopting international standards;
* Replace ISO 4401 with GB/T 2514 modified to adopt international standards (see Chapter 8);
* Replace ISO 5783 with GB/T 14043 which is equivalent to adopting international standards (see 4:3);
* Replace ISO 5598 with GB/T 17446 which is equivalent to adopting international standards (see Chapter 3);
* Removed ISO 3601-2:2008 (see ISO 6263:2013, Chapters 2 and 5:1):
The following editorial changes have also been made to this document:
--- Modify the installation surface code "6263-x-x-x-13" to "GB/T 8100:2-x-x-x-2021":
Please note that some content of this document may be patented: The issuing agency of this document assumes no responsibility for identifying patents:
Introduction
In a hydraulic transmission system, power is transmitted and controlled by pressurized fluid in a closed circuit: The hydraulic valve is the most typical in the system
A type of element that controls the flow direction, pressure or flow of a fluid in a closed loop:
GB/T 8100 specifies the dimensions of the installation surface of hydraulic valves, which are to be composed of 5 parts:
--- Part 1: Four-port directional valve: The purpose is to determine the size of the installation surface of the four-port directional valve (temporarily GB/T 2514-2008):
--- Part 2: Speed control valve: The purpose is to determine the size of the mounting surface of the speed control valve:
--- Part 3: Pressure reducing valves, sequence valves, unloading valves, throttle valves and check valves: The purpose is to determine the pressure reducing valve, sequence valve, unloading valve, joint
Dimensions of the mounting surface for flow valves and check valves:
--- Part 4: Relief valve: The purpose is to determine the size of the mounting surface of the relief valve (temporarily GB/T 8101-2002):
--- Part 5: Four-port and five-port servo valves: The purpose is to determine the size of the installation surface of the four-port and five-port servo valves (temporarily for
GB/T 17487-1998):
The five parts of GB/T 8100 are formulated by ISO 's independent standards: In order to facilitate the systematic management and implementation of the standards, the independent standards are
The quasi-combination is a sub-section standard:
Hydraulic valve mounting surface part 2: speed regulating valve
1 Scope
This document specifies the dimensions and related data of the speed control valve mounting surface to ensure the interchangeability of use:
This document applies to the speed control valve mounting surface commonly used in industrial equipment:
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text: Among them, the dated reference documents, only
The version corresponding to this date applies to this document; for undated references, the latest edition (including all amendments) applies to this document:
GB/T 786:1 Graphical symbols and circuit diagrams of fluid transmission systems and components - Part 1: Graphical symbols (GB/T 786:1-
2021, ISO 1219-1:2012, IDT)
GB/T 2514 Hydraulic transmission four-port directional control valve mounting surface (GB/T 2514-2008, ISO 4401:2005, MOD)
GB/T 14043 Identification code of hydraulic transmission valve mounting surface and valve hole of cartridge valve (GB/T 14043-2005, ISO 5783:
1995, IDT)
GB/T 17446 Vocabulary of Fluid Transmission Systems and Components (GB/T 17446-2012, ISO 5598:2008, IDT)
3 Terms and Definitions
Terms and definitions defined in GB/T 17446 apply to this document:
4 symbols
4:1 The following symbols apply to this document:
a) A, B, L, P, T and V indicate ports;
b) F1, F2, F3 and F4 indicate threaded holes for fixing screws;
c) G, G1 and G2 indicate positioning pin holes;
d) D represents the diameter of the fixing screw;
e) rmax represents the edge fillet radius of the mounting surface:
4:2 The graphic symbols used in this document shall comply with the provisions of GB/T 786:1:
4:3 The codes in this document shall comply with the provisions of GB/T 14043:
5 Tolerance
5:1 The mounting surface (that is, the area within the double-dotted line) should adopt the following tolerances:
---Surface roughness: Ra<=0:8µm;
---Surface flatness: no more than 0:01mm per 100mm;
--- Locating pin hole diameter tolerance: H12:
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — all pages — is available in the English PDF.
Referenced standards
Normative references
GB/T 786 · ISO 1219 · GB/T 2514 · GB/T 2514-2008 · ISO 4401 · GB/T 14043 · GB/T 14043-2005 · ISO 5783 · GB/T 17446 · GB/T 17446-2012 · ISO 5598
How to Buy GB/T 8100.2-2021
- 1Add to cart. Click the "Buy GB/T 8100.2-2021" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 14043.1-2022 — Hydraulic fluid power - Code and identification of valve - Part 1: Mounting surfaces and cavities
GB/T 25141-2022 — Self-priming rotodynamic pumps
GB/T 25142-2010 — Air-cooled circulating cooling liquid refrigerating packages
Secure payment via Stripe
Payments accepted
GB/T 8100.2-2021
$305.00