GB/T 24581-2022Test method for III and V impurities content in single crystal silicon—Low temperature FT-IR analysis method (English PDF)
硅单晶中III、V族杂质含量的测定 低温傅立叶变换红外光谱法
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 24581-2022 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
March 9, 2022
Implementation date
October 1, 2022
Scope
GB/T 24581-2022 is the English-translated version of 硅单晶中III、V族杂质含量的测定 低温傅立叶变换红外光谱法.
GB/T 24581-2022 is the Chinese national method for measuring group III and group V impurities in single crystal silicon by low temperature Fourier transform infrared spectroscopy.
It gives the principle, the apparatus and the cryogenic conditions, the specimen and its preparation, the measurement of the absorption lines, the calculation of the concentration of each element and the test report.
It applies to aluminium, antimony, arsenic, boron, gallium, indium and phosphorus in silicon single crystal, over a range from 1.0x10^10 cm^-3 to 4.1x10^14 cm^-3.
Crystal growers and the analytical laboratories of a wafer plant use it. It replaces GB/T 24581-2009, was issued on 9 March 2022 and has applied since 1 October 2022.
Found what you need?
Document preview — GB/T 24581-2022
National Standard of the People's Republic of China
- ICS
- 77.040
- Classification
- H 17
- Replacing
- GB/T 24581-2009
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and Definitions
- 4 Principles of the method
- 5 Interfering factors
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" drafted.
This document replaces GB/T 24581-2009 "Low-temperature Fourier Transform Infrared Spectrometry Determination of the Content of Group III and V Impurities in Silicon Single Crystals" Compared with GB/T 24581-2009, in addition to structural adjustment and editorial changes, the main technical changes are as follows.
a) Deleted "Purpose" (see Chapter 1 of the.2009 edition);
b) Changed the measurement range of boron (B), phosphorus (P), arsenic (As), aluminum (Al), antimony (Sb), gallium (Ga), and increased the measurement of indium (In) content (see Chapter 1, Chapter 2 of the.2009 edition);
c) Changed terms and definitions (see Chapter 3, Chapter 5 of the.2009 edition);
d) The measurement conditions for samples with impurity content less than 5.0x10^11 cm-3 are added (see 5.6);
e) The second strong absorption band P (275cm-1) is used to calculate the content of phosphorus (P) element (see 5.8);
f) Added the effect of doped silicon single crystal on the measurement (see 5.9);
g) Changed the method of polycrystalline transformation into single crystal (see 5.12, 8.1 of the.2009 edition);
h) Changed the requirements for Fourier transform infrared spectrometers (see 7.4, 7.4 of the.2009 edition);
i) Added micrometer and its accuracy requirements (see 7.5);
j) Changed the spectral range of non-zero response values (see 9.2, 10.2 of the.2009 edition);
k) Changed the number of scans of the background spectrum (see 9.7, 11.5 of the.2009 edition);
l) Changed the number of scans for samples (see 9.10, 11.8 of the.2009 edition);
m) The peak position, baseline and integration range and calibration factor corresponding to P(275cm-1) are added in Table 1 (see 10.1);
n) The unit of impurity content has been changed, and the calculation formula has been revised accordingly (see 10.4, 13.1 and 13.2 of the.2009 edition);
o) Changed the precision of the measurement results (see Chapter 11, Chapter 15 of the.2009 edition);
p) Changed the content of the test report (see Chapter 12, Chapter 14 of the.2009 edition);
q) Deletion of deviations and keywords (see Chapters 16 and 17 of the.2009 edition).
1 Scope
This document describes a method for the determination of group III and V impurities in silicon single crystals by low temperature Fourier transform infrared spectroscopy.
This document applies to group III and V impurities containing aluminum (Al), antimony (Sb), arsenic (As), boron (B), gallium (Ga), indium (In) and phosphorus (P) in silicon single crystals.
The measurement range of each element (in terms of atomic number) is 1.0x10^10 cm-3 ~ 4.1x10^14 cm-3.
2 Normative references
The contents of the following documents constitute essential provisions of this document through normative references in the text. Among them, dated citations documents, only the version corresponding to that date applies to this document; for undated references, the latest edition (including all amendments) applies to this document.
GB/T 8322 Molecular Absorption Spectroscopy Terminology
GB/T 14264 Terms of Semiconductor Materials
GB/T 29057 Procedures for evaluating polycrystalline silicon rods by zone melting method and spectroscopic analysis
3 Terms and Definitions
Terms and definitions defined in GB/T 8322 and GB/T 14264 apply to this document.
4 Principles of the method
When the silicon single crystal sample is cooled to below 15K, the infrared spectrum is mainly a series of absorption bands caused by impurity elements. use one A continuous white light source illuminates the sample so that the light energy is greater than the energy band of the compensating impurity. The infrared beam is directly transmitted through the sample, and the transmitted light is collected The spectrum is converted into an absorption spectrum after subtracting the background spectrum. Establish baselines on characteristic absorption bands of impurity elements and calculate their absorption bands area. The content of group III and V impurity elements is calculated according to the general absorption law and the calibration factors for group III and V impurity elements given in this document.
5 Interfering factors
5.1 In order to eliminate the influence of free carriers, the sample should be cooled to below 15K to measure group III and V impurity elements. Fix the sample on the cold head When the sample is in contact with the cold head, good contact should be maintained to obtain a high heat transfer efficiency. Oxygen absorption at 1136cm-1 and 1128cm-1 The collected band is very sensitive to temperature and can be used to judge the sample temperature. When the sample temperature is higher than 15K, the absorption intensity of oxygen at 1136cm-1 is 3 times the absorption intensity of 1128cm-1; while below 15K, the ratio will be greater than 3.
5.2 If there is not enough continuous white light, the donor and acceptor of compensation will not produce absorption, so there should be enough intensity of white light to completely cancel.
Compensation for all donors and recipients. The area or height of the absorption peaks of group III and V impurities can be determined by gradually increasing the white light intensity of the instrument. Optimal white light intensity affected by increased light intensity.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
Cited by
- GB/T 29057-2023Practice for evaluation of polocrystalline silicon rods by float-zone crystal growth and spectroscopy
- GB/T 30652-2023Trichlorosilane for silicon epitaxial
- GB/T 35307-2023Granular polysilicon produced by the fluidized bed method
- GB/T 4059-2018Test method for phosphorus content in polycrystalline silicon by zone-melting method under controlled atmosphere
- GB/T 25074-2017Solar-grade polycrystalline silicon
Similar standards
Editions of GB/T 24581
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 24581-2022 | Test method for III and V impurities content in single crystal silicon—Low temperature FT-IR analysis method | current edition | Current |
| GB/T 24581-2009 | Test method for III and V impurities content in single crystal silicon—Low temperature FT-IR analysis method | previous edition | Superseded |
This page sells the current edition, GB/T 24581-2022. Earlier editions are listed for reference only.
How to Download GB/T 24581-2022
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 14264-2024 — Terminology of semiconductor materials
GB/T 29057-2023 — Practice for evaluation of polocrystalline silicon rods by float-zone crystal growth and spectroscopy
GB/T 8322-2008 — Molecular absorption spectrometry -- Terminology
Secure payment via Stripe
Payments accepted
GB/T 24581-2022
$150.00