GB/T 2315-2017Specified failure load series and coupling dimensions for electric power fittings (English PDF)
电力金具标称破坏载荷系列及连接型式尺寸
This is a limited preview
Buy now to download the full PDF (15 pages)
Need quotation for your management?
Get a formal quotation for GB/T 2315-2017 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
December 29, 2017
Implementation date
July 1, 2018
Scope
GB/T 2315-2017 is the English-translated version of 电力金具标称破坏载荷系列及连接型式尺寸.
GB/T 2315-2017 is the Chinese national standard that fixes the series of specified failure loads for electric power fittings and the dimensions of their couplings.
It applies to the fittings used on overhead power lines, and it defines the specified failure load as the minimum load at which mechanical failure must not occur, together with the clevis and tongue, ring and ring, and ball and socket couplings.
The failure load series is divided into eighteen grades, each with its marking, bolt diameter and the tensile strength required of the material. Clause 5 gives the coupling dimensions and their deviations, including the GQ marking for fittings of 640 kN and above, and clause 6 gives the test method.
It replaces GB/T 2315-2008, was issued on 29 December 2017 and has applied since 1 July 2018.
Found what you need?
Document preview — GB/T 2315-2017
National Standard of the People's Republic of China
- ICS
- 29.240.20
- Classification
- K 51
- Replacing
- GB/T 2315-2008
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 nominal damage load series
- 5 connection type
- 6 test method
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 2315-2008 "power fittings nominal breaking load series and connection type size", and GB/T 2315-2008 compared to the main technical changes are as follows.
--- Added "Groove connection" "ring connection" "ball and socket connection" definition (see 3.2 ~ 3.4);
--- The nominal damage load increased from 13 levels to 18 levels, and lists the nominal damage load corresponding to the mark and so on (See Chapter 4, Chapter 4 of the 2008 edition);
--- Increasing the size of the groove connection size, according to the new markings listed bolt aperture requirements (see 5.1.1, 2008 edition 5.1.1);
--- The tensile strength of the material marked as 55 and above shall be changed from ">=500MPa" to ">=650MPa" (see 5.1.1, 2008 edition 5.1.1);
--- Groove-connected bolts should be consistent with the standard from "GB/T 3098.1" to "DL/T 764" (see 5.2.1, 2008 edition 5.1.2);
--- Added the requirement of "GQ" mark after "640kN and above nominal breaking load fittings" (see 5.1.3, 5.2.2 and 5.3.3);
--- Increasing the groove connection, ring connection size deviation requirements (see 5.1.4,5.2.3);
--- Increased the size of the ring connection range, according to the new label lists the ring diameter and other requirements (see 5.2.1, 2008 version 5.2.1);
--- Modify the standard of ball joint connection size from "GB/T 4056" to "GB/T 4056 and DL/T 1579" (see 5.3.2, 2008 edition of 5.3.1).
1 Scope
This standard specifies the power fittings nominal sabotage load series and groove, ring and ball socket connection size.
This standard applies to overhead power line power fittings (hereinafter referred to as fittings).
2 Normative references
The following documents for the application of this document is essential. For dated references, only the dated version applies to this document. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 2314 electrical fittings general technical conditions
GB/T 2317.1 Test methods for electrical fittings - Part 1: Mechanical tests
GB/T 4056 insulator string ball socket connection size
DL/T 764 power fittings with pin hole hexagon head bolts
DL/T 1579 rod suspension composite insulator end fittings technical specifications
3 Terms and definitions
The following terms and definitions apply to this document.
3.1 Nominal damage load
Specified does not allow the occurrence of mechanical damage to the minimum load.
3.2 Groove connection
By the veneer, slot and connecting pins and other connections.
3.3 Ring connection
A ring and ring connection.
3.4 Ball and socket connection
Foot ball and hat made of the connection.
4 Nominal damage load series
Nominal damage load series is divided into 18 levels, the marking, bolt diameter and tensile strength of materials in Table 1.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 2314General technical requirements for electric power fittings
- GB/T 2317.1Test method for electric power fittings -- Part 1: Mechanical tests
- GB/T 4056Dimensions of ball and socket couplings of string insulator units
- DL/T 1579Technical specification for end fittings for composite insulators for overhead lines
DL/T 764
Cited by
- GB/T 24834-2023Technical specification for fittings of 1000kV AC overhead transmission line
- GB/T 31239-2023Technical specification for fittings of 1000kV substation
- JB/T 9680-2012Insulators for ground-wires of high voltage overhead transmission lines
- GB/T 2314-2008General technical requirements for electric power fittings
Similar standards
Editions of GB/T 2315
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 2315-2017 | Specified failure load series and coupling dimensions for electric power fittings | current edition | Current |
| GB/T 2315-2008 | Specified failure load series and coupling dimensions for electric power fittings | previous edition | Superseded |
This page sells the current edition, GB/T 2315-2017. Earlier editions are listed for reference only.
How to Download GB/T 2315-2017
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
DL/T 1579-2024 — Technical specification for end fittings for composite insulators for overhead lines
DL/T 764.1-2025 — Fasteners for electrical fittings - Part 1: Hex-head bolts with pin holes in rods
DL/T 764.2-2025 — Fasteners for electrical fittings - Part 2: Fastening hex head bolts and nuts
Secure payment via Stripe
Payments accepted
GB/T 2315-2017