GB/T 4056-2019Dimensions of ball and socket couplings of string insulator units (English PDF)
绝缘子串元件的球窝联接尺寸
This is a limited preview
Buy now to download the full PDF (57 pages)
Need quotation for your management?
Get a formal quotation for GB/T 4056-2019 in 30 minutes.
Issued by
State Administration for Market Regulation, China National Standardization Administration
Level / Type
National · Recommended
Issue date
December 10, 2019
Implementation date
July 1, 2020
Scope
GB/T 4056-2019 is the English-translated version of 绝缘子串元件的球窝联接尺寸.
GB/T 4056-2019 — This standard specifies the standard ball and socket coupling series dimensions using standard locking pins (see GB/T 25318-2019), including foot balls and hat sockets The dimensions of insulator installations and their tolerances are also specified in the inspection gauges required to check these dimensions so that insulators or metal The pieces are interchangeable.
This standard applies to disc-shaped and long rod-shaped insulator string components with ball and socket connections and their metal accessories. The size of the ball and cap socket specified in this standard is applicable to the finished product after any surface treatment.
The extreme position of the foot ball in the hat socket is given in Appendix A. Note. This standard only covers the dimensions necessary for installation, and does not specify material properties and workload.
The combination of the connection mark and the strength level is in GB/T 7253- Provisions in.2019 and GB/T 26874-2011.
Found what you need?
Document preview — GB/T 4056-2019
National Standard of the People's Republic of China
- ICS
- 29.080.10
- Classification
- K 48
Issued by: State Administration for Market Regulation, China National Standardization Administration
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 terms and definitions
- 4 foot ball
- 5 Hatwell
Foreword
This standard was drafted in accordance with the rules given in GB/T 1.1-2009.
This standard replaces GB/T 4056-2008 "Ball and socket connection dimensions of insulator string components". This standard is in accordance with GB/T 4056-2008
The main technical changes are as follows.
--- Combining Chapters 1, 2, and 3 of the.2008 edition into Chapter 1 "Scope" (see Chapter 1, Chapters 1 and 2 of the.2008 edition
Chapters 2 and 3).
This standard uses the redrafting method to modify and adopt IEC 60120. 1984 "Ball and socket connection dimensions of insulator string elements".
Compared with IEC 60120. 1984, the structure of this standard has the following changes.
--- Combine Chapters 1, 2 and 3 of IEC 60120. 1984 into Chapter 1 "Scope" (see Chapter 1);
--- Added "normative references" "terms and definitions" (see Chapters 2 and 3).
The technical differences between this standard and IEC 60120. 1984 and their causes are as follows.
--- Regarding the normative reference documents, this standard has made adjustments with technical differences to suit China's technical conditions and the situation of adjustment.
The situation is reflected in Chapter 2 "Regulatory Reference Documents", and the specific adjustments are as follows.
* Replaced IEC 60372..2003 with GB/T 25318-2019 that adopted the international standard (see Chapter 3, Chapter 10,
Chapter 15);
* Added references to GB/T 1001.1-2003, GB/T 2900.8-2009, and GB/T 26874-2011 (see Chapter 3).
--- Table 1 ~ Table 8, Table A.1 ~ Table A.2, Table B.1 ~ Table B.9, added the connection marks 36 and 40 and their size data.
--- The labeling of the connection marks 36 and 40 has been added in FIG. 2.
The following editorial changes have been made to this standard.
--- Increased references.
This standard was proposed by the China Electrical Equipment Industry Association.
This standard is under the jurisdiction of the National Insulator Standardization Technical Committee (SAC/TC80).
This standard was drafted. Xi'an High Voltage Apparatus Research Institute Co., Ltd., China Electric Power Research Institute Co., Ltd., Dalian Power
Porcelain Group Transmission and Transformation Material Co., Ltd., Suzhou Electric Porcelain Factory Co., Ltd., Sichuan Yibin Global Group Co., Ltd., Nanjing Electric
Yuanzi Co., Ltd., General Electric Power Planning and Design Institute, China Southern Power Grid Scientific Research Institute Co., Ltd., China Power Engineering Consulting Group East China Power
Li Design Institute, Sadieville Glass Insulators (Shanghai) Co., Ltd., National Insulator Lightning Arrester Quality Supervision and Inspection Center, NGK Tangshan Electric
Porcelain Co., Ltd., Sinoma Jiangxi Electric Porcelain Electric Co., Ltd., Inner Mongolia Jingcheng High Voltage Insulator Co., Ltd., Zhejiang Tailun Insulator Co., Ltd.
Company, State Grid Zhejiang Power Co., Ltd. Electric Power Research Institute, State Grid Jiangsu Power Co., Ltd. Electric Power Research Institute, State Grid Ningxia
Electric Power Research Institute of Electric Power Co., Ltd., Chongqing University, Changyuan High-Energy Electric Co., Ltd., Guangzhou Maikeling Power Equipment Co., Ltd.,
Pingxiang Best Electric Co., Ltd., Pingxiang Huawei Electric Porcelain Technology Co., Ltd., Xi'an Guanghui Mould Co., Ltd.
With), Sanrui Technology Jiangxi Co., Ltd., Zibo Electric Porcelain Factory Co., Ltd., Xiangyang State Grid Synthetic Insulator Co., Ltd., Zibo Taiguang
Power equipment factory.
1 Scope
This standard specifies the standard ball and socket coupling series dimensions using standard locking pins (see GB/T 25318-2019), including foot balls and hat sockets
The dimensions of insulator installations and their tolerances are also specified in the inspection gauges required to check these dimensions so that insulators or metal
The pieces are interchangeable.
This standard applies to disc-shaped and long rod-shaped insulator string components with ball and socket connections and their metal accessories.
The size of the ball and cap socket specified in this standard is applicable to the finished product after any surface treatment.
The extreme position of the foot ball in the hat socket is given in Appendix A.
Note. This standard only covers the dimensions necessary for installation, and does not specify material properties and workload. The combination of the connection mark and the strength level is in GB/T 7253-
Provisions in.2019 and GB/T 26874-2011.
2 Normative references
The following documents are essential for the application of this document. For dated references, only the dated version applies to this document. For undated references, the latest version (including all amendments) applies to this document.
GB/T 1001.1-2003 Insulators for overhead lines with a nominal voltage higher than 1000V Part 1. Porcelain or glass for AC systems
Insulator component definition, test method and judgment criteria (IEC 60383-1..1993, MOD)
GB/T 2900.8-2009 Insulators for electrical terms (IEC 60050-471..2007, IDT)
GB/T 25318-2019 Lock pin dimensions and tests for ball and socket connection of insulator string components (IEC 60372..2003, MOD)
GB/T 26874-2011 Characteristics of long rod porcelain insulators for high voltage overhead lines (IEC 60433..1998, MOD)
3 terms and definitions
Terms defined in GB/T 1001.1-2003, GB/T 2900.8-2009, GB/T 25318-2019 and GB/T 26874-2011
And definitions apply to this document.
4 foot ball
The main dimensions of the ball shall comply with the provisions of Chapter 9. The main dimensions controlling the shape of the ball are h1, d2, r1 and r2. Exact size r3
Values can only be obtained by plotting and are given for reference only. In addition, the connecting length of the foot bar should be in the range of H3 (see Chapter 11)
Within the range, the diameter of the foot rod d1 should not exceed the specified value.
5 Hatwell
The main dimensions of the cavity of the hat socket and the minimum thickness of the locking pin should be in accordance with Chapter 10.
Note 1. The hat sockets described in this chapter are flat-bottomed. A hat socket with a round bottom with a radius of curvature not less than the ball's size r2 can also be used. In this case, size R5
Will be reduced accordingly.
Note 2. There are two sizes of hat sockets with standard coupling mark 16 in Chapter 10.A and B sizes are the same except for sizes H1, H2 and T
At the same time, there is only one type of steel foot that matches it, and the locking pin used corresponds to that.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 57 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 1001.1-2003Insulators for overhead lines with a nominal voltage above 1 000V - Part 1: Ceramic or glass insulator units for a. c. systems - Definitions, test methods and acceptance criteria
- GB/T 2900.8-2009Electrotechnical terminology -- Insulators
- GB/T 25318-2019Locking devices for ball and socket couplings of string insulator units - Dimensions and tests
- GB/T 26874-2011Characteristics of ceramic insulator units of the long rod type for high-voltage overhead lines
IEC 60383 · IEC 60050 · IEC 60372 · IEC 60433
Cited by
- GB/T 2317.4-2023Test method for electric power fittings - Part 4: Acceptance inspection
- GB/T 1001.1-2021Insulators for overhead lines with a nominal voltage above 1 000V - Part 1: Ceramic or glass insulator units for a. c. systems - Definitions, test methods and acceptance criteria
- GB/T 21421.1-2021Composite string insulator units for overhead lines with a nominal voltage greater than 1 000 V - Part 1: Standard strength classes and end fittings
- GB/T 25318-2019Locking devices for ball and socket couplings of string insulator units - Dimensions and tests
- GB/T 7253-2019Insulators for overhead lines with a nominal voltage above 1 000 V - Ceramic or glass insulator units for a.c. systems - Characteristics of insulator units of the cap and pin type
- GB/T 19443-2017Insulators for overhead lines with a nominal voltage above 1 500 V - Ceramic or glass insulator units for d.c. systems - Definitions, test methods and acceptance criteria
How to Download GB/T 4056-2019
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 25318-2019 — Locking devices for ball and socket couplings of string insulator units - Dimensions and tests
GB/T 26874-2011 — Characteristics of ceramic insulator units of the long rod type for high-voltage overhead lines
GB/T 2900.8-2009 — Electrotechnical terminology -- Insulators