Valid

GB/T 22788-2016Determination of total lead content in material of toys and children’s products (English PDF)

玩具及儿童用品材料中总铅含量的测定

Preview PDF

This is a limited preview

Buy now to download the full PDF (15 pages)

Need quotation for your management?

Get a formal quotation for GB/T 22788-2016 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

December 13, 2016

Implementation date

July 1, 2017

Scope

GB/T 22788-2016 is the English-translated version of 玩具及儿童用品材料中总铅含量的测定.

GB/T 22788-2016 prescribes the methods for determining the total lead content in the materials of toys and children's products. Clause 1 states that the determination applies to the surface coatings and to the metallic and non-metallic materials of such articles.

Its contents run from clause 1 Scope through Normative references, Terms and definitions, Principles, Reagents or materials, Instruments and equipment, Analysis steps, Calculation of results, Precision, Detection limit of the method and Test report, and close with informative Appendix A on the working conditions of the flame atomic absorption spectrometer, informative Appendix B holding precision data from interlaboratory tests, and a list of references.

Clause 7 gives a separate digestion route for each family of material, always on about 0.2 g of sample weighed to 1 mg: coatings are digested with nitric acid and hydrogen peroxide either on an electric hot plate or in a microwave vessel held at (180 plus or minus 5) degrees C, metallic materials with hydrochloric and nitric acid by either of the same two routes, ceramics, glass, crystal and other silicon-bearing non-metallic materials in a sealed PTFE vessel with nitric and hydrofluoric acid at (185 plus or minus 5) degrees C with boric acid solution added afterwards, and plastics, polymers and other silicon-free non-metallic materials with nitric acid at (205 plus or minus 5) degrees C, each digest being made up to 25 mL and a parallel blank test being run with the same reagents and no sample.

The measurement is made by flame atomic absorption spectrometry, the test solution being aspirated into an acetylene-air flame and read against a lead hollow cathode lamp on a standard curve whose linear correlation coefficient must be at least 0.995, and a note allows a laboratory to use other validated techniques such as graphite furnace AAS, ICP-OES or ICP-MS, with attention to matrix interference.

Its terms and definitions are those of GB 6675.4, and the other normative references are GB/T 602, GB/T 6379.2 and GB/T 6682. A warning at the head of the document states that the people using it must have practical experience of formal laboratory work and remain responsible for the appropriate safety and health measures.

It replaces GB/T 22788-2008, was issued on December 13, 2016 and has applied since July 1, 2017.

Found what you need?

Document preview — GB/T 22788-2016

National Standard of the People's Republic of China

ICS
97.200.50
Classification
Y 57
Replacing
GB/T 22788-2008

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Terms and definitions4
  • 4 Principles5
  • 5 Reagents or materials5
  • 6 Instruments and equipment6
  • 7 Analysis steps6
  • 8 Calculation of results10
  • 9 Precision10
  • 10 Detection Limit of the Method10
  • 11 Test report10
  • Appendix A (Informative) Working conditions of FAAS12
  • Appendix B (Informative) Precision data from interlaboratory test results13
  • References14

1 Scope

This standard specifies the determination methods of total lead content in materials of toys and children's products.

This standard is applicable to the determination of total lead content in surface coatings, metallic and non-metallic materials of toys and children's products.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard.

GB/T 602 Chemical reagent -- Preparations of standard solutions for impurity

GB/T 6379.2 Measurement methods and results -- Accuracy (trueness and precision) -- Part 2: Determine the standard methods of measurement repeatability and reproducibility of the basic method

GB 6675.4 Safety of toys -- Part 4: Migration of certain elements

GB/T 6682 Water for analytical laboratory use -- Specification and test methods

3 Terms and definitions

Terms and definitions defined in GB 6675.4 are applicable to this document.

7 Analysis steps

of hydrogen peroxide (5.3), and continue heating; repeat the step 1~2 times until the digestion of the sample is complete. When the solution is left about 1 mL, remove the beaker and let it cool to room temperature. Dilute the solution with about 10 mL of water, filter the solution into a 25 mL volumetric flask, and then use 5 mL of nitric acid (5.6) in total to rinse the beaker and filter paper three times. Transfer the washing solution into the 25 mL volumetric flask. The mixed solution will be determined later.

In the process of adding hydrogen peroxide, special attention shall be paid to the possible risk of solution bumping or overflow.

7.2.1.2 Microwave digestion method

Weigh about 0.2 g of the sample, and the weight shall be accurate to 1 mg; place it in a microwave digestion vessel, respectively add 5 mL of nitric acid (5.2) and 2 mL of hydrogen peroxide (5.3), and seal the digestion vessel. Carry out the digestion according to the following temperature program: raise the temperature to (180 ± 5) °C in about 10 minutes, and keep the temperature for 30 minutes; then, let the temperature go down. After the digestion tank is cooled to room temperature, open the digestion tank, and transfer the digestion solution to a 25 mL volumetric flask; wash the inner tank and inner lid of the microwave digestion vessel three times with a small amount of nitric acid (5.6), and incorporate the washing solution into the volumetric flask. If the digestion solution is not clear or has precipitation, the solution shall be filtered, and the residual solid substances shall be washed 3 times with 5 mL of nitric acid (5.6) in total; then, transfer the washing solution into the 25 mL volumetric flask. The mixed solution will be determined later. […]

7.2.2 Metallic materials

Note: This standard provides two digestion methods for metallic materials, which can be selected by the laboratory technicians according to the conditions.

7.2.2.1 Electric hot plate heating digestion method

Weigh about 0.2 g of the sample, and the weight shall be accurate to 1 mg; put it into a 50 mL beaker, add 6 mL of hydrochloric acid (5.4) and 2 mL of nitric acid (5.2), and heat it on an electric hot plate to keep the solution slightly boiling; digest it for about 15 minutes; if the dissolution of the sample is not complete, remove the beaker and cool it down, add 0.5 mL~2 mL of nitric acid (5.2) and a few drops of hydrochloric acid (5.4), and then continue heating; repeat the step 1~2 times to complete the digestion of the sample; when the solution is left about 1mL, remove the beaker and let it cool to room temperature. Dilute with about 10 mL of water, filter the solution into a 25 mL volumetric flask, and then rinse the beaker and filter paper three times with 5 mL of nitric acid (5.6) in total. Transfer the washing solution into the 25 mL volumetric flask. The mixed solution will be determined later.

7.2.2.2 Microwave digestion method

Weigh about 0.2 g of the sample, and the weight shall be accurate to 1 mg; place it in a microwave digestion vessel of polytetrafluoroethylene, add 6 mL of nitric acid (5.2) and 2 mL of hydrochloric acid (5.4), and seal the digestion vessel after the reaction subsides at room temperature. Carry out the digestion according to the following temperature program: raise the temperature to (180 ± 5) °C in about 6 minutes, and keep the temperature for 5 minutes before cooling down. After the vessel is cooled to room temperature, open the vessel, transfer the solution to a 25 mL volumetric flask; wash the inner tank and inner lid of the microwave digestion vessel three times with a small amount of nitric acid (5.6), and incorporate the washing solution into the volumetric flask. If the digestion solution is not clear or has precipitation, the solution shall be filtered, and the residual solid substances shall be washed three times with 5 mL of nitric acid (5.6) in total; then, transfer the washing solution into the 25 mL volumetric flask. The mixed solution will be determined later.

7.2.3 Ceramics, glass, crystal, and other non-metallic materials containing silicon

Weigh about 0.2 g of the sample, and the weight shall be accurate to 1 mg; place it in a microwave digestion vessel of polytetrafluoroethylene, add 6 mL of nitric acid (5.2) and 1 mL of hydrofluoric acid (5.5), and seal the vessel after the reaction subsides; place the vessel in a microwave digestion apparatus, and carry out the digestion according to the following temperature program: raise the temperature to (185±5) °C in about 6 minutes, and maintain the temperature for 10 minutes before cooling down. After the vessel is cooled to room temperature, open the vessel, add 8 mL of boric acid solution (5.9) to the digestion tank, and then transfer the solution to a 25 mL plastic volumetric flask; wash the inner tank and the inner lid of the microwave digestion vessel three times with a small amount of nitric acid (5.6), and incorporate the washing solution into the plastic volumetric flask. If the digestion solution is not clear or has precipitation, the solution shall be filtered, and the remaining solid substances shall be washed 3 times with 5 mL of nitric acid (5.6) in total; transfer the washing solution to the 25 mL plastic volumetric flask. The mixed solution will be determined later.

Wear acid and alkali-resistant gloves and gas masks during operation to prevent inhalation of hydrofluoric acid or skin contact.

7.2.4 Plastics, polymers, and other silicon-free non-metallic materials

Weigh about 0.2 g of the sample, and the weight shall be accurate to 1 mg; put it into a microwave digestion vessel of polytetrafluoroethylene, add 7 mL of nitric acid (5.2), and seal the vessel after the reaction subsides; place the vessel in a microwave digestion apparatus, and carry out the digestion according to the following temperature program: raise the temperature to (205±5) °C in about 20min, and maintain the temperature for 10min before cooling down. After the vessel is cooled to room temperature, open the vessel, and transfer the solution to a 25 mL volumetric flask; wash the inner tank and inner lid of the microwave digestion vessel three times with a small amount of nitric acid (5.6), and incorporate the washing solution into the volumetric flask. If the digestion solution is not clear or has precipitation, the solution shall be filtered, and the residual solid substances shall be washed three times with 5 mL of nitric acid (5.6) in total. Transfer the washing solution into the 25 mL volumetric flask. The mixed solution will be determined later.

7.2.5 Blank test

Carry out a blank test, and the blank test shall be carried out in parallel; adopt the same analysis steps, and use the same amount of all reagents; however, no sample is added.

7.3 Determination

7.3.1 General rule

Use a flame atomic absorption spectrometer to determine. Let the test solution be sucked into the acetylene-air flame, and determine the absorption value of the selected spectral lines emitted from a lead hollow cathode lamp. Calculate the measured value according to the standard curve.

Note: The testing laboratory technicians can also use other validated detection methods, such as graphite furnace atomic absorption spectrometry (GFAAS), inductively coupled plasma optical emission spectrometry (ICP-OES), or inductively coupled plasma mass spectrometry (ICP-MS); special attention should be paid to the matrix interference during the analysis by ICP-MS or ICP-OES.

7.3.2 Selection of instrument working conditions

See Appendix A for the working conditions of the flame atomic absorption spectrometer.

7.3.3 Standard curve

When digesting the sample by the electric hot plate heating digestion method, determine the absorbance values of the lead series standard working solutions 1 (5.11) in order of concentration from low to high. When digesting the sample by the microwave digestion method, determine the absorbance values of the lead series standard working solutions 2 (5.12) in order of concentration from low to high. Take the absorbance as the ordinate and the concentration as the abscissa to draw the standard curve, and calculate the correlation coefficient. The linear correlation coefficient shall be >=0.995.

7.3.4 Determination of lead in sample solutions

Under the same conditions as drawing the standard curve, determine the concentration values of the blank test solution and the sample solution. If the content of lead in the sample solution exceeds the maximum concentration value of the standard curve, then before the determination, the solution shall be properly diluted with nitric acid that is […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 15 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 22788

EditionTitleRevisionStatus
GB/T 22788-2016Determination of total lead content in material of toys and children’s productscurrent editionCurrent
GB/T 22788-2008Determination of total lead content in material of toys and children’s productsprevious editionSuperseded

This page sells the current edition, GB/T 22788-2016. Earlier editions are listed for reference only.

How to Download GB/T 22788-2016

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
15 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 22788-2016