GB/T 20473-2021Dry-mixed thermal insulating mortar for buildings (English PDF)
建筑保温砂浆
This is a limited preview
Buy now to download the full PDF (16 pages)
Need quotation for your management?
Get a formal quotation for GB/T 20473-2021 in 30 minutes.
Issued by
SAMR; SAC
Level / Type
National · Recommended
Issue date
August 20, 2021
Implementation date
March 1, 2022
Scope
GB/T 20473-2021 is the English-translated version of 建筑保温砂浆.
GB/T 20473-2021 is the Chinese national standard for the dry-mixed thermal insulating mortar used on buildings.
It gives the classification and the designation, the technical requirements - the dry density, the thermal conductivity, the compressive and bond strength, the water absorption, the shrinkage and the fire behaviour - the test methods, the inspection rules and the provisions on packaging, marking and storage.
It applies to dry-mixed mortar for building thermal insulation. Mortar producers, façade contractors and building inspectors use it. It replaces GB/T 20473-2006, was issued on 20 August 2021 and has applied since 1 March 2022.
Found what you need?
Document preview — GB/T 20473-2021
National Standard of the People's Republic of China
- ICS
- 91.100.60
- Classification
- Q 25
- Replacing
- GB/T 20473-2006
Issued by: State Administration for Market Regulation; Standardization Administration of the PRC
Contents
- Foreword
- 1 Scope
- 2 Normative references
- 3 Terms and definitions
- 4 Classification and marking
Foreword
This document is in accordance with the provisions of GB/T 1.1-2020 "Guidelines for Standardization Work Part 1: Structure and Drafting Rules of Standardization Documents" Drafting.
This document replaces GB/T 20473-2006 "Building Insulation Mortar". Compared with GB/T 20473-2006, except for structural adjustment and editing In addition to the sexual changes, the main technical changes are as follows.
---Modified the scope (see Chapter 1, Chapter 1 of the 2006 edition);
---Modified the technical requirements for bulk density (see 5.2, 5.2 of the 2006 edition);
---Cancel the stratification degree and increase the technical requirements for the 2h consistency loss rate (see 5.5, 5.5 in the 2006 edition);
---Modified the technical requirements for dry density and compressive strength (see Table 1, Table 1 of the 2006 edition);
---Increase the technical requirements for tensile bond strength, volumetric water absorption, and heat storage coefficient (see Table 1);
---Modified the technical requirements of softening coefficient (see 5.7.2, 5.8 in 2006 edition);
---Increase maintenance conditions and test environment (see 6.1);
---Increase numerical rounding (see 6.2);
---Modified the test method of asbestos content (see 6.5, 6.3 of the 2006 edition);
---Increase the test method of 2h consistency loss rate (see 6.7);
---The test method to increase the volumetric water absorption (see 6.10);
--- Increase the tensile bond strength test method (see Appendix D);
---Modified the compression-shear bond strength test method (see Appendix E, 2006 edition of 6.6.5);
---Modified the frost resistance test method (see Appendix F, 2006 edition of 6.7);
--- Increase the heat storage coefficient test method (see Appendix G).
1 Scope
This document specifies the classification and marking, technical requirements, test methods, inspection rules, packaging, marking and storage of building insulation mortar.
This document applies to dry-mixed mortar for building thermal insulation.
2 Normative references
The contents of the following documents constitute the indispensable clauses of this document through normative references in the text. Among them, dated quotations Only the version corresponding to that date is applicable to this document; for undated reference documents, the latest version (including all amendments) is applicable to this document.
GB/T 191 Packaging, storage and transportation pictorial signs
GB/T 4132 Thermal insulation materials and related terms
GB/T 5486 Test Method for Inorganic Rigid Thermal Insulation Products
GB 6566 Radionuclide limits for building materials
GB/T 8170-2008 Numerical rounding rules and the expression and determination of limit values
GB 8624 Classification of burning performance of building materials and products
GB/T 10294 Determination of steady-state thermal resistance and related characteristics of thermal insulation materials. Protective hot plate method
GB/T 10295 Determination of steady-state thermal resistance and related characteristics of thermal insulation materials by calorimeter method
GB/T 10297 Determination of thermal conductivity of non-metallic solid materials by hot wire method
GB/T 12954.1-2008 Construction adhesive test method Part 1: Ceramic tile adhesive test method
GB/T 33395 Determination of asbestos in paint
BB/T 0065 dry mixed mortar packaging bag JG244 mixer for concrete test
JGJ/T 12-2019 Technical Standard for Lightweight Aggregate Concrete Application
JGJ/T 70 Standard for basic performance test method of building mortar
3 Terms and definitions
The following terms and definitions defined in GB/T 4132 apply to this document.
3.1 Dry-mixed thermal insulating mortar
A dry-mix mortar made of expanded perlite, vitrified microbeads, expanded vermiculite, etc. as aggregates, mixed with cementitious materials and other functional components.
4 Classification and marking
4.1 Classification
The products are divided into type I and type II according to their performance.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 191Graphical symbols marking for handling and storage of packages
- GB/T 4132Thermal insulation - Vocabulary
- GB/T 5486Test methods for inorganic rigid thermal insulation products
- GB 6566Limits of radionuclides in building materials
- GB/T 8170-2008Rules of rounding off for numerical values & expression and judgement of limiting values
- GB 8624Classification for burning behavior of building materials and products
Cited by
- JG/T 532-2018Insulation board with surface-vitrified and expanded perlite for building
- JG/T 435-2014General specification of inorganic lightweight aggregate board for fireproof and insulation
- JC/T 2182-2013Dry-mixed mortar mixer
- JC/T 2200-2013Foamed cement insulation panel
- SB/T 10647-2011Quality management specification of dry-mixed mortar
Similar standards
Editions of GB/T 20473
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 20473-2021 | Dry-mixed thermal insulating mortar for buildings | current edition | Current |
| GB/T 20473-2006 | Dry-mixed thermal insulating mortar for buildings | previous edition | Superseded |
This page sells the current edition, GB/T 20473-2021. Earlier editions are listed for reference only.
How to Download GB/T 20473-2021
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB 6566-2010 — Limits of radionuclides in building materials
GB 8624-2012 — Classification for burning behavior of building materials and products
GB 8624-2025 — Classification for burning behavior of building materials and products
Secure payment via Stripe
Payments accepted
GB/T 20473-2021
$240.00