GB/T 19282-2014Analytic method for Lithium hexafluorophosphate (English PDF)

六氟磷酸锂产品分析方法

Preview PDF

This is a limited preview

Buy now to download the full PDF (16 pages)

Need quotation for your management?

Get a formal quotation for GB/T 19282-2014 in 30 minutes.

Issued by

SAMR; SAC

Level / Type

National · Recommended

Issue date

September 3, 2014

Implementation date

May 1, 2015

Scope

GB/T 19282-2014 is the English-translated version of 六氟磷酸锂产品分析方法.

This standard specifies the identification of lithium hexafluorophosphate products and the analytical methods for the related physical and chemical indicators, and clause 1 applies it to lithium hexafluorophosphate products.

The whole of the technical content sits in clause 3, Analytical methods, whose general provisions require first-grade pure reagents and first-grade water as specified in GB/T 6682-2008 and the preparation of the standard solutions, impurity standard solutions and reagent solutions according to HG/T 3696.1, HG/T 3696.2 and HG/T 3696.3 unless other requirements are specified.

The clause then runs through an identification test and the determination of cation content by the standard addition method and by the working curve method, both carried out on an inductively coupled plasma optical emission spectrometer fitted with a hydrofluoric acid-resistant sampling system, each result being reported as a mass fraction in mg/kg.

The determination of anion content separates the chloride ion and the sulfate ion on a chromatographic column and detects them with a conductivity detector, quantifying by the external standard method on an ion chromatograph resistant to fluoride corrosion, with a column resolution of not less than 1.5, a filter membrane of 0.45 micrometre or finer and deionized water whose conductivity at 25 degrees Celsius is not greater than 0.0055 mS/m.

Separate subclauses determine the chloride ion content with nitric acid solution and silver nitrate solution against a chloride standard solution, and the sulfate content by visual turbidimetry, in which barium ions and sulfate ions form insoluble barium sulfate in hydrochloric acid medium and the turbidity of the dissolved specimen is compared with standard turbidity solutions prepared from a sulfate standard solution with hydrochloric acid, absolute ethanol and barium chloride solution.

Moisture is determined on the principle of clause 3 of GB/T 6283-2008, with an automatic coulometric moisture analyzer and about 0.5 g of specimen weighed to 0.001 g in a glove box of dew point below minus 40 degrees Celsius; the dimethyl carbonate insoluble content is found by dissolving the specimen in dimethyl carbonate, filtering it through a 0.45 micrometre hydrofluoric acid-resistant membrane and drying it at 105 degrees Celsius plus or minus 2 degrees Celsius to constant mass; and the free acid content is obtained with a micro-burette by titrating about 10 g of specimen dissolved in ice water with a sodium hydroxide standard titration solution of about 0.01 mol/L against bromothymol blue, the result being expressed as the mass fraction of hydrofluoric acid.

Clause 2 cites GB/T 6283-2008, GB/T 6682-2008, HG/T 3696.1, HG/T 3696.2 and HG/T 3696.3, and the informative Appendix A gives recommended operating conditions for the ion chromatograph.

It replaces GB/T 19282-2003, was issued on September 3, 2014 and has applied since May 1, 2015.

Found what you need?

Document preview — GB/T 19282-2014

National Standard of the People's Republic of China

ICS
71.060.01
Classification
G 10
Replacing
GB/T 19282-2003

Issued by: State Administration for Market Regulation; Standardization Administration of the PRC

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Analytical methods5
  • Appendix A (Informative) Recommended ion chromatograph operating conditions16

1 Scope

This standard specifies the identification of lithium hexafluorophosphate products AND the analytical methods of related physical and chemical indicators.

This standard applies to lithium hexafluorophosphate products.

2 Normative references

The following documents are essential to the application of this document. For the dated documents, only the versions with the dates indicated are applicable to this document; for the undated documents, only the latest version (including all the amendments) is applicable to this standard.

GB/T 6283-2008 Chemical products - Determination of water Karl.Fischer method (general method)

GB/T 6682-2008 Water for analytical laboratory use - Specification and test methods

HG/T 3696.1 Inorganic chemicals for industrial use - Preparations of standard and reagent solutions for chemical analysis - Part 1: Preparations of standard volumetric solutions

HG/T 3696.2 Inorganic chemicals for industrial use - Preparations of standard and reagent solutions for chemical analysis - Part 2: Preparations of standard solutions for impurity

HG/T 3696.3 Inorganic chemicals for industrial use - Preparations of standard and reagent solutions for chemical analysis - Part 3: Preparations of reagent solutions

3 Analytical methods

3.1 General provisions

The reagents and water, which are used in this standard, refer to the first-grade pure reagents and the first-grade water, which are specified in GB/T 6682-2008, unless other requirements are specified. For the standard solutions for chemical analysis, standard solutions of impurities, preparations and products, which are used in the test, they shall be prepared in accordance with the provisions of HG/T 3696.1, HG/T 3696.2, HG/T 3696.3, unless other requirements are specified.

3.2 Identification test

3.3 Determination of cation content

3.3.1 Standard addition method
3.3.1.1 Method summary

The content of each cation in the specimen is determined, by standard addition method, on an inductively coupled plasma optical emission spectrometer (ICP-OES), which has a hydrofluoric acid-resistant sampling system.

3.3.1.2 Reagents
3.3.1.3 Instruments and equipment
3.3.1.4 Analytical procedures
3.3.1.4.1 Preparation of test solutions
3.3.1.5 Result calculation

The cation content is calculated in mass fraction w1; the value is expressed in mg/kg; it is calculated according to formula (1).

3.3.2 Working curve method
3.3.2.1 Method summary

The content of each cation in the specimen is determined, by the working curve method, on an inductively coupled plasma optical emission spectrometer (ICP-OES), which has a hydrofluoric acid-resistant sampling system.

3.3.2.2 Reagents

It complies with the requirements, which are given in 3.3.1.2.

3.3.2.3 Instruments and equipment

It complies with the requirements, which are given in 3.3.1.3.

3.3.2.4 Analytical procedures
3.3.2.5 Result calculation

The cation content is calculated in mass fraction w1; the value is expressed in mg/kg; it is calculated according to formula (2).

3.4 Determination of anion content

3.4.1 Method summary

The chloride ion and sulfate ion, in lithium hexafluorophosphate, are separated by chromatographic column; detected by conductivity detector. The content of detected anion is calculated by external standard method.

3.4.2 Reagents

3.4.2.1 Water. Deionized water, which has a conductivity (25 °C) not greater than 0.0055 mS/m.

3.4.2.2 Ice water. Add an appropriate amount of ice cubes to the water. Use it, when the water temperature is <= 4 °C.

3.4.2.3 Regeneration fluid. According to the suppressor used and its usage, refer to the instruction manual of the suppressor, to select a suitable regeneration fluid.

3.4.3 Instruments and equipment

3.4.3.1 Ion chromatograph. An analytical system, which is resistant to fluoride corrosion.

3.4.3.1.1 Chromatographic column. The resolution of the detected anion R >= 1.5.

3.4.3.1.2 Filter membrane. <= 0.45 µm.

3.4.3.1.3 Detector. Conductivity detector, or other detectors, if it can be confirmed that it has the same function.

3.4.3.2 Volumetric flask. Polyethylene or other corrosion-resistant materials, which have a volume of 100 mL.

3.4.4 Analytical procedures
3.4.4.1 Preparation of working curve solution

Use a suitable pipette, to pipette each standard use solution into four 100 mL volumetric flasks, according to the provisions of Table 2. Use water to dilute it to the mark. Shake well.

3.4.5 Result calculation

The mass fraction of anion content is calculated in w2; the value is expressed in mg/kg; it is calculated according to formula (3).

3.5 Determination of chloride ion content

3.5.1 Reagents

3.5.1.1 Nitric acid solution. 1 + 2.

3.5.1.2 Silver nitrate solution. 17 g/L.

3.5.1.3 Chloride standard solution. 1 mL solution contains 1 µg of chloride (Cl). Pipette 10 mL of chloride standard solution, which is prepared according to HG/T 3696.2. Put it in a 100 mL volumetric flask. Use water to dilute it to the mark. Shake well. Pipette 1 mL into a 100 mL volumetric flask. Use water to dilute it to the mark. Shake well. Store it at 4 °C. The validity period is 30 days.

3.5.2 Analytical procedures

3.6 Determination of sulfate content

3.6.1 Method principle

In hydrochloric acid medium, barium ions and sulfate ions form insoluble barium sulfate. When the content of sulfate ions is low, barium sulfate will be in suspension, within a certain period of time, making the solution turbid, which can be determined, by the visual turbidimetry.

3.6.2 Reagents

3.6.2.1 Absolute ethanol.

3.6.2.2 Hydrochloric acid solution. 1 + 1.

3.6.2.3 Barium chloride solution. 250 g/L.

3.6.2.4 Sulfate standard solution. 1 mL solution contains 1.0 µg of sulfate (SO4). Pipette 10 mL of sulfate standard solution, which is prepared according to HG/T 3696.2. Put it in a 100 mL volumetric flask. Use water to dilute it to the mark. Shake well. Pipette 1 mL into a 100 mL volumetric flask. Use water to dilute it to the mark. Shake well. Store it at 4 °C. The validity period is 30 days.

3.6.3 Analytical procedures
3.6.3.1 Preparation of standard turbidity solution

Pipette 0.00 mL, 5.00 mL, 10.00 mL, 15.00 mL of sulfate standard solution, into a 25 mL colorimetric tube, respectively. Add 0.3 mL of hydrochloric acid solution and 3 mL of absolute ethanol in sequence. Then use water to dilute it to 25 mL. Shake well. Add 2 mL of chlorine barium chloride solution. Shake well.

3.6.3.2 Determination

Weigh about 5 g of the specimen in the glove box, accurate to 0.01 g. Take it out and place it in a polyethylene beaker, which is filled with 15 mL of water. Dissolve and filter it into a 25 mL colorimetric tube. Then treat it, together with the standard turbidity solution at the same time. The turbidity of the solution is compared with that of the standard turbidity solution.

3.7 Determination of moisture

3.7.1 Method principle

Same as Chapter 3 of GB/T 6283-2008.

3.7.2 Instruments and equipment

3.7.2.1 Automatic moisture analyzer. Coulomb coulometric method.

3.7.2.2 Glove box. dew point < -40 °C.

3.7.3 Analytical procedures

The analytical procedure shall be carried out in a glove box. Weigh about 0.5 g of the specimen, accurate to 0.001 g. Put the specimen into the measuring bottle of the automatic moisture analyzer, until it is completely dissolved. Stir evenly. Then measure its moisture.

3.7.4 Result calculation

The mass fraction w3 of water, expressed in mg/kg, is calculated according to formula (4).

3.8 Determination of dimethyl carbonate (DMC) insoluble content

3.8.1 Method summary

Use dimethyl carbonate to dissolve the specimen. Use a membrane filtration device to filter it. Dry it at 105 °C ± 2 °C, until the mass is constant.

3.8.2 Reagents

Dimethyl carbonate (DMC). Moisture < 0.0010%.

3.8.3 Instruments and equipment

3.8.3.1 Membrane filtration device. 1000 mL, which is matched with a filter membrane with a diameter of 50 mm.

3.8.3.2 Filter membrane. The material is polytetrafluoroethylene or other hydrofluoric acid-resistant filter membrane, which has a pore size of 0.45 µm and a diameter of 50 mm.

3.8.3.3 Vacuum pump and filter equipment.

3.8.3.4 Magnetic stirrer.

3.8.3.5 Beaker. It has lid AND is made of polyethylene or other corrosion-resistant material.

3.8.3.6 Electric heating constant temperature drying box. An explosion-proof constant temperature box, whose temperature can be controlled at 105 °C ± 2 °C.

3.8.5 Result calculation

The insoluble content of dimethyl carbonate (DMC) is calculated in mass fraction w4; the value is expressed in mg/kg; it is calculated according to formula (5).

3.9 Determination of free acid content

3.9.1 Method summary

Use a micro-burette. Use bromothymol blue as an indicator. Use standard titration solution of sodium hydroxide, to titrate the free acid in the specimen.

3.9.2 Reagents

3.9.2.1 Sodium hydroxide standard titration solution. c(NaOH) ~ 0.01 mol/L

Preparation. Pipette 100 mL of sodium hydroxide standard solution, which is prepared according to HG/T 3696.1. Place it in a 1000 mL volumetric flask. Use carbon dioxide-free water to dilute it to the mark. Shake well.

3.9.2.2 Ice water. Add an appropriate amount of ice cubes to the water. Use it when the water temperature is <= 4 °C.

3.9.2.3 Bromothymol blue indicator solution. 1 g/L.

3.9.3 Instruments and equipment
3.9.4 Analytical procedures

Weigh about 10 g of the sample by weight loss method, accurate to 0.0002 g. Quickly pour the sample into a beaker, which contains 100 mL of ice water. Shake the beaker, to dissolve the specimen quickly. Add 10 drops of bromothymol blue indicator solution.

Use sodium hydroxide standard titration solution, to rapidly titrate it to light blue (no color fading in 10 s), which is the end point. At the end point, the temperature of the solution shall still remain <= 4 °C.

3.9.5 Result calculation

The free acid content is calculated in terms of the mass fraction w5 of hydrofluoric acid (HF); the value is expressed in mg/kg; it is calculated according to formula (6). […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 16 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 19282

EditionTitleRevisionStatus
GB/T 19282-2014Analytic method for Lithium hexafluorophosphatecurrent editionCurrent
GB/T 19282-2003Analytic method for Lithium hexafluorophosphateprevious editionSuperseded

This page sells the current edition, GB/T 19282-2014. Earlier editions are listed for reference only.

How to Download GB/T 19282-2014

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
16 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 19282-2014

$205.00