GB/T 18280.3-2015Sterilization of health care products -- Radiation -- Part 3: Guidance on dosimeter aspects (English PDF)
This is a limited preview
Buy now to download the full PDF (27 pages)
Need quotation for your management?
Get a formal quotation for GB/T 18280.3-2015 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Level / Type
National · Recommended
Issue date
December 31, 2015
Implementation date
January 1, 2018
Scope
GB/T 18280.3-2015 (Sterilization of health care products -- Radiation -- Part 3: Guidance on dosimeter aspects) is available as an English-translated PDF.
GB/T 18280.3-2015 — This Part of GB/T 18280 gives guidance on the requirements in GB 18280 parts 1 and
Found what you need?
Document preview — GB/T 18280.3-2015
National Standard of the People's Republic of China
- ICS
- 11.080.01
- Classification
- C 47
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China
Contents
- Foreword...3
- Introduction...5
- 1 Scope...6
- 2 Normative references...6
- 3 Terms and definitions...6
- 4 Measurement of dose...7
- 5 Selection and calibration of dosimetry systems...7
- 6 Establishing the maximum acceptable dose...8
- 7 Establishing the sterilization dose...8
- 8 Installation qualification...10
- 9 Operational qualification...11
- 10 Performance qualification...17
- 11 Routine monitoring and control...21
- Annex A (informative) Mathematical modelling...23
- Bibliography...27
Foreword
GB 18280 consists of the following parts, under the general title Sterilization of health
care products - Biological indicators.
- Part 1. Requirements for development, validation and routine control of a
sterilization process for medical devices;
- Part 2. Establishing the sterilization dose;
- Part 3. Guidance on dosimetric aspects.
This Part is Part 3 of GB 18280.
This Part is drafted in accordance with the rules given in GB/T 1.1-2009.
This Part partly replaces GB 18280-2000 "Sterilization of health care products -
Requirement for validation and routine control - Radiation sterilization". Compared with
GB 18280-2000, this Part was developed from Annex C of GB 18280-2000, main
technical content changes in this Part are as follows.
- ADD the introduction to sterilization dose;
- ADD the requirements for Installation Qualification, Operational Qualification
and Performance Qualification;
- ADD the requirements for routine monitoring and control.
This Part uses translation method to identically adopt ISO 11137-3.2006 "Sterilization
of health care products - Radiation - Part 3. Guidance on dosimetric aspects" (English
version).
China's documents that are identical to the International documents normatively
referenced in this Part are as follows.
- GB 18280.1-2015 Sterilization of health care products - Radiation - Part 1.
Requirements for development, validation and routine control of a sterilization
process for medical devices (ISO 11137-1.2006, IDT)
- GB 18280.2-2015 Sterilization of health care products - Radiation - Part 2.
Establishing the sterilization dose (ISO 11137-2.2006, IDT)
Attention is drawn to the possibility that some of the elements of this document may
be the subject of patent rights. The issuing organizations of this document shall not be
held responsible for identifying any or all such patent rights.
This Part was proposed by State Food and Drug Administration.
This Part shall be under the jurisdiction of National Technical Committee on
Sterilization Techniques and Equipment of Standardization Administration of China
(SAC/TC 200).
Drafting organizations of this Part. Beijing Radiation Application Research Center,
Shenzhen JPY Ion-tech Co., Ltd., Guangzhou Medical Devices Quality Surveillance
and Test Institute of State Food and Drug Administration.
Main drafters of this Part. Hu Jinhui, Chen Qiang, Wu Weirong, Zeng Mingsheng, Bao
Yu and Hu Yang.
The previous edition of the standard replaced by this Part is as follow.
- GB 18280-2000.
Sterilization of health care products - Radiation –
Part 3. Guidance on dosimetric aspects
1 Scope
This Part of GB/T 18280 gives guidance on the requirements in GB 18280 parts 1 and
2 relating to dosimetry. Dosimetry procedures related to the development, validation
and routine control of a radiation sterilization process are described.
2 Normative references
The following referenced documents are indispensable for the application of this
document. For dated references, only the edition cited applies. For undated references,
the latest edition of the referenced document (including any amendments) applies.
ISO 11137-1 Sterilization of health care products - Radiation - Part 1. Requirements
for development, validation and routine control of a sterilization process for medical
devices
ISO 11137-2.2006 Sterilization of health care products - Radiation - Part 2.
Establishing the sterilization dose
3 Terms and definitions
For the purposes of this document, the terms and definitions given in ISO 11137-1,
ISO 11137-2 and the following apply.
3.1
dosimetry system
Interrelated elements used for determining absorbed dose, including dosimeters,
instruments, associated reference standards and procedures for their use.
[ISO/TS 11139.2005]
[19] SHARPE, P. and MILLER, A. Guidelines for the Calibration of Dosimeters for use
in Radiation Processing. NPL Report CIRM 29, National Physical Laboratory,
Teddington, TW11 0LW, UK (1999)
[20] Panel on Gamma and Electron Irradiation, Guidance Notes on the Dosimetric
Aspects of Dose-setting Methods, The Panel on Gamma & Electron Irradiation,
212 Piccadilly, London, W1J 9HG, UK (1996)
[21] Panel on Gamma and Electron Irradiation, Discussion Paper on Uncertainties in
Routine Dosimetry for Gamma and EB Plants, The Panel on Gamma & Electron
Irradiation, 212 Piccadilly, London, W1J 9HG, UK (2002)
......
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 27 pages — is available in the English PDF.
Referenced standards
Normative references
ISO 11137
Cited by
- GB/T 45351-2025Manufacture of cell-based medical devices - Control of microbial risks during processing
- GB/T 12279.1-2024Cardiovascular implants - Cardiac valve prostheses - Part 1: General requirements
- GB/T 44138-2024Cardiovascular implants - Cardiovascular absorbable implants
- YY 0861-2024Ophthalmic optics - Ophthalmic viscosurgical devices
- YY/T 1743-2021Anaesthetic and respiratory equipment—Nebulizing systems and components
- YY/T 0726-2020Instrumentation for use in association with non-active surgical implants - General requirements
How to Download GB/T 18280.3-2015
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 7463-2026 — Surface active agents - Determination of the power to disperse calcium soap - Acidimetric method (Modifled Schoenfeldt method)
GB/T 8336-2026 — Special threads gauges for gas cylinders
GB/T 48115-2026 — Technical requirements for GNSS radio occultation detection payload
Secure payment via Stripe
Payments accepted
GB/T 18280.3-2015
$100.00