GB/T 17116.2-2018Pipe supports and hangers - Part 2: Pipe attachments (English PDF)
管道支吊架 第2部分:管道连接部件
Open the GB/T 17116.2-2018 preview as PDF
This is a limited preview
Buy now to download the full PDF (73 pages)
Issued by
General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC
Level / Type
National · Recommended
Issue date
February 6, 2018
Implementation date
September 1, 2018
Scope
GB/T 17116.2-2018 is the English-translated version of 管道支吊架 第2部分:管道连接部件.
China's national dimensional standard for the components that connect a support to the pipe itself. It is Part 2 of GB/T 17116 and specifies the nominal size series, the load series, the temperature classes, the materials, the types and the main dimensions of the typical structural forms of pipe attachments, and it applies to the pipe-connecting components of supports and hangers on round-section metal pipe of controlled outside diameter. The pipe attachment is where the support meets the line, and it is the component that has to reconcile two incompatible requirements. It must transmit the whole weight of the pipe and its contents into the hanger, and it must do so without becoming a thermal short circuit that drains heat out of a hot line, without cutting into the insulation, and without creating a local restraint or a stress concentration on the pipe wall. The forms that solve that problem are standardised here: the clamps that grip the pipe, the welded lugs and shoes that carry insulated lines clear of the support, the trunnions, the straps and the riser clamps that take vertical lines. Because a piping designer selects a support before the fabricator makes it, what matters is that a size and a load class mean the same thing to both. So the part is organised as series: nominal sizes, load ratings and temperature classes, and for each type of attachment the material to be used at each temperature class and the main connection dimensions - so that a component ordered from one shop fits the intermediate hardware of Part 3 supplied by another. Issued on 6 February 2018 and in force since 1 September 2018, it replaces GB/T 17116.2-1997.
Document preview — GB/T 17116.2-2018
National Standard of the People's Republic of China
- ICS
- 23.040.99
- Classification
- J 15
- Replacing
- GB/T 17116.2-1997
Issued by: General Administration of Quality Supervision, Inspection and Quarantine; Standardization Administration of the PRC
Contents
- 1 Scope
- 2 Normative references
- 3 Relevant dimensions of the pipe structure
- 3.1 Nominal size series of pipe structure
- 3.2 Minimum inner diameter of the pipe structure
- 4 Pipe structure type 1 non-integral pipe structure
- 4.1 Load level
- 4.2 Load series Table
- 5 Piping system grading and pipe material matching
- 5.1 Piping system classification
- 5.2 Pipe material matching
- 6.1 Pipe Structure Classification
- 6.2 Pipe Structure Type
- 6.3 Mark
- 7 Requirements
- 7.1 General requirements
- 7.2 Horizontal Pipe Department
- 7.3 Riser pipe department
- 7.4 Rolling support
Foreword
GB/T 17116 "Pipe Supporting and Hanging" is divided into the following three parts.
--- Part 1. Technical specifications;
--- Part 2. Pipe connection parts;
--- Part 3. Intermediate connectors and building structure connectors. This part is the second part of GB/T 17116. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part replaces GB/T 17116.2-1997 "Pipe Support and Hanger Part 2. Pipe Connection Parts", and GB/T 17116.2- In.1997, the main technical changes except editorial changes are as follows:
--- Increase the two pipe specifications of DN2700 and DN2900;
--- Added lightweight and flexible small load tube structure;
--- Deepen the energy-saving and environmentally friendly insulation and hanger structure;
--- Added copper tube series;
--- Changed the load classification method;
--- Added chapters on load series, temperature class and material, pipe structure type, etc.;
--- The main size of the typical pipe structure is changed to an informative appendix. This part was proposed by the China Machinery Industry Federation. This part is under the jurisdiction of the National Pipeline Attachment Standardization Technical Committee (SAC/TC237). This section is responsible for drafting the unit. Zhongji Guoneng Power Engineering Co., Ltd. Participated in the drafting of this section. China Power Engineering Consulting Group East China Electric Power Design Institute Co., Ltd., China Machine Productivity Promotion Center, China National Electric Power Engineering Consulting Group Northwest Electric Power Design Institute Co., Ltd., China Petroleum Engineering Construction Corporation East China Design Branch, China Tianchen Engineering Co., Ltd., China Energy Construction Group Guangdong Electric Power Design and Research Institute Co., Ltd., Jiangsu Electric Power Equipment Co., Ltd., Huadian Power Science Research Institute, Jiangsu Yuxin Technology Co., Ltd., Zhejiang Zhenshen Thermal Insulation Technology Co., Ltd., Shanghai Xinqi Hardware Co., Ltd. The main drafters of this section. Xiong Jianwen, Lin Lei, Feng Feng, Chen Yunfen, Su Yinping, Ma Xinqiang, Liu Jian, Liu Jun, Huang Tao, Pu Wansheng, Guo Yanjun, Cao Yandong, Shen Zhongguang, Lin Qiluo, Zhang Chunhua, Chen Xunyu. The previous versions of the standards replaced by this section are.
---GB/T 17116.2-1997. Pipe hanger Part 2. Pipe connection parts
1 Scope
China's national dimensional standard for the components that connect a support to the pipe itself. It is Part 2 of GB/T 17116 and specifies the nominal size series, the load series, the temperature classes, the materials, the types and the main dimensions of the typical structural forms of pipe attachments, and it applies to the pipe-connecting components of supports and hangers on round-section metal pipe of controlled outside diameter. The pipe attachment is where the support meets the line, and it is the component that has to reconcile two incompatible requirements. It must transmit the whole weight of the pipe and its contents into the hanger, and it must do so without becoming a thermal short circuit that drains heat out of a hot line, without cutting into the insulation, and without creating a local restraint or a stress concentration on the pipe wall. The forms that solve that problem are standardised here: the clamps that grip the pipe, the welded lugs and shoes that carry insulated lines clear of the support, the trunnions, the straps and the riser clamps that take vertical lines. Because a piping designer selects a support before the fabricator makes it, what matters is that a size and a load class mean the same thing to both. So the part is organised as series: nominal sizes, load ratings and temperature classes, and for each type of attachment the material to be used at each temperature class and the main connection dimensions - so that a component ordered from one shop fits the intermediate hardware of Part 3 supplied by another. Issued on 6 February 2018 and in force since 1 September 2018, it replaces GB/T 17116.2-1997.
This part of GB/T 17116 specifies the nominal size series, load series, temperature class and the number of pipe connecting and connecting pipe connecting parts. The main dimensions of the materials, types and typical structural types. This section applies to the structure of various types of hangers and tubes of circular metal pipes that control the outer diameter.
2 Normative references
The following documents are indispensable for the application of this document. For dated references, only dated versions apply to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document.
GB/T 713 steel plate for boiler and pressure vessel
GB 3274 carbon structural steel and low alloy structural steel hot rolled thick steel plate and steel strip
GB/T 3531 steel plate for low temperature pressure vessel
GB/T 5310 seamless steel pipe for high pressure boiler
GB/T 17116.1 Pipe hangers and hangers - Part 1. Technical specifications
GB/T 17116.3 Pipe hangers and hangers - Part 3. Intermediate joints and building structural joints
GB/T 17393 Specification for Thermal Insulation Materials for Austenitic Stainless Steel
GB/T 24511 stainless steel plate and steel strip for pressure equipment
3 Relevant dimensions of the pipe structure
3.1 Nominal size series of pipe structure The pipe and hanger structure shall comply with the nominal size series of Table 1. The pipe outer diameters A and B are applicable to steel pipes. The C series is suitable for cast iron pipes and the D series is suitable for copper pipes.
3.2 Minimum inner diameter of the pipe structure
3.2.1 The pipe structure directly connected to the pipeline shall have a minimum internal diameter as specified in Table 2. a pipe structure connected to the outer insulation layer of the pipe, The minimum inner diameter should not be less than the sum of the maximum outer diameter of the pipe and the thickness of the insulation layer twice.
3.2.2 The tolerance of the inner diameter of the pipe structure shall comply with the provisions of GB/T 17116.1. Table
1 Nominal size series of pipe structure Nominal size DN Pipe outer diameter/mm Series A Series B Series C Series D Nominal size DN Pipe outer diameter/mm Series A Series B Series C Series D 10 17.2 14 12 900 914 920 945 15 21.3 18 18 950 965 20 26.9 25 22 1000 1016 1020 1048 25 33.7 32 28 1050 1067 32 42.4 38 35 1100 1118 1120 1152 40 48.3 45 56 42 1150 1168 50 60.3 57 66 54 1200 1219 1220 1255 65 73 76 82 76 1300 1321 1320 80 88.9 89 98 89 1400 1422 1420 1462 90 101.6 1500 1524 1520 1565 100 114.3 108 118 108 1600 1626 1620 1668 125 141.3 133 144 133 1700 1727 1720 150 168.3 159 170 159 1800 1829 1820 1875 175 193.7 194 1900 1930 1920 200 219.1 219 222 219.2000 2032 2020 2082 225 244.5 245 2100 2134 2120 250 273.0 273 274 273 2200 2235 2220 2288 275 298.5 298 2300 2337 2320 300 323.9 325 326 325 2400 2438 2420 2495 350 355.6 377 378 2500 2540 2520 . 400 406.4 426 429 2600 2642 2620 2702 450 457 480 480 2700 2743 2720 500 508 530 532 2800 2845 2820 550 559 2900 2946 2920 600 610 630 635 3000 3048 3020 650 660 3200 3251 3220 700 711 720 738 3400 3454 3420 750 762 3600 3658 3620 800 813 820 842 3800 3861 3820 850 864 4000 4064 4020 Table
2 Minimum inner diameter table of pipe structure Nominal size DN Pipe structure minimum inner diameter/mm Series A Series B Series C Series D Nominal size DN Pipe structure minimum inner diameter/mm Series A Series B Series C Series D 10 17.7 14.5 12.1 900 928 934 946 15 21.8 18.5 18.1 950 982 0 20 27.4 25.5 22.1 1000 1031 1035 1049 25 34.2 32.5 28.1 1050 1078 0 32 42.9 38.5 35.1 1100 1130 1132 1153 40 48.8 45.5 57 42.1 1150 1179 0 50 61 57.6 67 54.1 1200 1231 1232 1256 65 74 77.0 83 76.1 1300 1335 1334 80 90.0 90 99 89.2 1400 1436 1434 1463 90 103 1500 1540 1536 1566 100 116 109 119 108.2 1600 1642 1636 1669 125 143 135 145 133.7 1700 1744 1737 150 171 161 171 159.7 1800 1847 1838 1876 175 197 197 1900 1949 1939 200 222 222 223 220.5.2000 2052 2040 2083 225 248 248 2100 2155 2141 250 277 277 275 274.5 2200 2257 2242 2289 275 303 2300 2360 2343 300 329 330 327 326.5 2400 2462 2444 2496 350 361 383 379 2500 2565 2545 400 412 432 430 2600 2655 2633 2703 450 464 487 481 2700 2757 2734 500 516 538 533 2800 2859 2834 550 567 2900 2961 2935 600 619 639 636 3000 3063 3035 650 670 3200 3267 3236 700 722 731 739 3400 3471 3437 750 773 3600 3677 3638 800 825 832 843 3800 3881 3839 850 877 4000 4085 4040
4 Pipe structure type 1 non-integral pipe structure
1.1 Horizontal tube hanger Type 110 Type 111 Type 112 Type 113 Type 114 Double bolt pipe clamp three bolt pipe clamp pipe clamp pipe clamp high temperature pipe clamp extension type separation pipe clamp Type 115 Type 116 Type 117 Type 118 Type 119 Short pipe clamp long pipe clamp rotating hoop J-shaped pipe hoop open pipe ring Type 11A Type 11B Type 11C Type 11D Type 11E Spiral opening pipe ring separation pipe clamp hinge pipe clamp double boom pipe clamp U-shaped pipe clamp Type 11F Type 11G Type 11H Boom pipe card cross arm suspension pipe clamp cross arm suspension pipe card cross arm Table 4 (continued)
1.2 Horizontal tube bracket Type 120 Type 121 Type 122 Type 123 Type 124 T-type pipe clamp bearing pipe clamp bearing pipe clamp bearing U-shaped pipe card pipe card Type 125 Type 126 Type 127 Type 128 Type 129 P-type tube card tube custody card tube holder adjustable tube holder adjustable tube card tube holder
1.3 riser hanger Type 130 Type 131 Type 132 Type 133 Four bolts riser pipe clamp six bolts riser pipe clamp ten bolts riser pipe clamp rib plate hanging plate hanger
1.4 riser bracket Type 140 Type 141 Type 142 Two bolt riser bracket three bolts single side riser bracket four bolt riser bracket Table 4 (continued)
1.5 insulated hanger Type 150 Type 151 Type 152 Type 153 Type 154 Double bolt insulated pipe clamp insulated pipe clamp double boom insulated pipe clamp double bolt separation type insulated pipe clamp with spiral opening pipe ring Type 155 Type 156 Type 157 Type 158 Type 159 Four bolt riser insulated pipe clamp boom insulated pipe card cross arm hanger pipe clamp cross arm adjustable roller hanger double boom roller hanger
1.6 insulation bracket Type 160 Type 161 Type 162 Type 163 Type 164 Shield insulation board card insulation tube card insulation tube holder support insulation tube card holder Type 165 Type 166 Type 167 Type 168 Type 169 Insulation P-type tube card insulation riser horizontal ear insulation double cone roller tube clamp bracket insulation double cylindrical roller tube clamp bracket insulation radial limit double support Table 4 (continued) Type 16A Type 16B Type 16C Adiabatic radial limit three-stand adiabatic radial limit four-support adiabatic T-tube support
1.7 Rolling hanger Type 170 Type 171 Type 172 Type 173 Type 174 Adjustable roller hanger double boom roller hanger double roller guide hanger pipe clamp pipe saddle pipe clamp pipe saddle
1.8 rolling bracket Type 180 Type 181 Type 182 Type 183 Type 184 Single cylindrical roller tube clamp bracket double cone roller tube clamp bracket Lateral displacement double cone rolling Tube holder Double cylindrical roller clamp bracket Double cylindrical roller clamp bracket ( >DN500) Type 185 Type 186 Type 187 Type 188 Anti-off-load double cylindrical roller Pipe clamp bracket Lateral displacement double cylindrical roller Bobbin clamp bracket Adjustable double cone roller Pipe clamp bracket Adjustable lateral displacement double cone Roller tube clamp bracket Table 4 (continued)
1.9 Special purpose pipe department Type 190 Type 191 Type 192 Type 193 Type 194 Radial limit tube clamp Double support Radial limit tube clamp Three seats Radial limit tube clamp Four seats Pipe clamp guide sleeve Radial limit, vibration damping, damping Single rod dynamic pipe clamp Type 195 Type 196 Type 197 Type 198 Type.199 Radial limit, vibration damping, damping Double rod dynamic pipe clamp Radial limit, vibration damping, damping Three single rod dynamic pipe clamp Axial limit pipe clamp Cross-arm radial limit, minus Vibration and damping dynamic carrier clamp Riser axial moving carrier clamp Type 19A Type 19B Axial stop for horizontal pipe (tube clamp type) Axial stop for horizontal pipe (pipe card type)
2 integral pipe structure
2.1 Horizontal pipe hanger Type 210 Type 211 Type 212 Type 213 Type 214 Welding hanging plate welding trunnion strengthening welding hanging plate strengthening welding hanging plate hanger cross arm hanger Table 4 (continued)
2.2 Horizontal tube bracket Type 220 Type 221 Type 222 Type 223 Type 224 Welding support reinforced welding support T-type support reinforced T-type seat type pipe support Type 225 type 226 Horizontal pipe support to strengthen horizontal pipe support
2.3 riser hanger Type 230 Type 231 Type 232 Veneer welding hanger double plate welding hanger trunnion hanger
2.4 riser bracket Type 240 Type 241 Type 242 Type 243 Type 244 Vertical pipe bracket wing plate veneer welding support double plate welding support trunnion welding support trunnion welding support Table 4 (continued)
4.1 Load level
4.1.1 The load series of pipe connecting and connecting pipe connecting parts are divided into 19 levels, see Table 3.
4.1.2 The nominal size of the pipe structure according to Table 1 shall be matched to the series of load sizes of the boom.
4.1.3 The maximum load of the boom should meet the requirements of GB/T 17116.1.
4.1.4 The nominal size of the boom and its thread series shall comply with the provisions of GB/T 17116.3.
4.2 Load Series Table The matching relationship between the pipe structure load series and the hanger's nominal size shall comply with the requirements of Table 3. Table
3 Load series table of pipe structure Load series 0 1 2 3 4 5 6 7 8 9 ABCDEFGHI Single boom Nominal size NS 10 10 12 16 20 24 30 36 42 48 56 64 68 72 80 90 100 110 125 Double boom Nominal size NS 10 10 10 12 16 20 24 30 36 36 42 56 56 56 64 68 80 80 90 pipeline Nominal size DN Load/kN 2 3.95.7110.917.124.739.761.284.4123 185 248 283 320 402 517 647 7911033 10 - 15 - 20 - 25 - - 32 - - 40 - - - 50 - - - - 65 - - 80 - - - 90 - - - 100 - - - 125 - - - 150 - - - 175 - - - 200 - - - - - 225 - - - - - 250 - - - - - 275 - - - - - 300 - - - - - - - 350 - - - - - - 400 - - - - - - - - - - 450 - - - - - - - - - - 500 - - - - - - - - - 550 - - - - - - - - - 600 - - - - - - - - - - 650 - - - - - - - - - - Table 3 (continued) Load series 0 1 2 3 4 5 6 7 8 9 ABCDEFGHI Single boom Nominal size NS 10 10 12 16 20 24 30 36 42 48 56 64 68 72 80 90 100 110 125 Double boom Nominal size NS 10 10 10 12 16 20 24 30 36 36 42 56 56 56 64 68 80 80 90 pipeline Nominal size DN Load/kN 2 3.95.7110.917.124.739.761.284.4123 185 248 283 320 402 517 647 7911033 700 - - - - - - - - - - - 750 - - - - - - - - - - - 800 - - - - - - - - - - - 850 - - - - - - - - - - - 900 - - - - - - - - - - - - - 950 - - - - - - - - - - - - - 1000 - - - - - - - - - - - - - 1050 - - - - - - - - - - - - - 1100 - - - - - - - - - - - - - 1150 - - - - - - - - - - - - - 1200 - - - - - - - - - - - - - 1300 - - - - - - - - - - - - 1400 - - - - - - - - - - - - 1500 - - - - - - - - - - - - 1600 - - - - - - - - - - - - 1700 - - - - - - - - - - - - 1800 - - - - - - - - - - - 1900 - - - - - - - - - - - 2000 - - - - - - - - - - - 2100 - - - - - - - - - - 2200 - - - - - - - - - - 2300 - - - - - - - - - - 2400 - - - - - - - - - 2500 - - - - - - - - - 2600 - - - - - - 2700 - - - - - - 2800 - - - - - - 2900 - - - - - - 3000 - - - - - - 3200 - - - - - - 3400 - - - - - - 3600 - - - - - - 3800 - - - - - - - 4000 - - - - - -
Note. - indicates that all types of hangers are applicable; - indicates that it is only applicable to brackets.
5.1 Piping system classification
5.1.1 Piping system classification shall comply with the provisions of GB/T 17116.1.
5.1.2 Pipe joints and hangers The main components of the pipe structure shall be used in accordance with the provisions of GB/T 17116.1.
5.2 Pipe material matching
5.2.1 The pipe material matching and temperature code in direct contact with the pipeline shall comply with the provisions of Appendix A.
5.2.2 The allowable load of pipe parts of different materials shall comply with the provisions of Appendix B.
6 pipe structure type
6.1 Classification of pipe structure The pipe structure is divided into two groups. non-integrated and integral. Each component is a horizontal pipe hanger, a horizontal pipe bracket, a riser hanger, a riser bracket, and a Hot hanger (integral for elbow (tube) hanger), insulated bracket (integral for elbow (tube) bracket), horizontal tube rolling hanger, horizontal tube rolling branch 9 types of racks and special purpose tubes.
6.2 Pipe structure type The pipe structure type is shown in Table 4. Table
7 Requirements
7.1 General requirements
7.1.1 Except as otherwise provided in this section, the material, design and production of the pipe structure shall comply with the provisions of GB/T 17116.1.
7.1.2 Except as otherwise provided in this part, the connection dimensions of the pipe structure and the intermediate connection of the pipe support and hanger or the structural connection of the building shall comply with The provisions of GB/T 17116.3.
7.1.3 Carbon steel pipe clamps are used for suspending or supporting horizontal or vertical pipe steel pipe clamps of stainless steel pipes and non-ferrous metal pipes, and should be in pipe clamps and pipes. The surface of the contact area is coated with a non-metallic insulating coating, an insulating protective film, an insulating gasket or a gasket of the same material as the pipe.
7.1.4 The structural material of the pipe that is in contact with the pipe shall be selected according to the design temperature of the pipe.
7.1.5 The pipe structural material welded directly to the pipe shall be the same or compatible with the pipe material.
7.2 Horizontal Pipe Department
7.2.1 Horizontal pipe support can be combined with sliding bottom plate, guiding bottom plate and limit bottom plate to form sliding bearing, guiding bearing and limit Support.
7.2.2 Double-bolt pipe clamps and three-bolt pipe clamps shall be provided with spacers.
7.2.3 When using horizontal pipe welding hangers or supports, the strength conditions and stiffness conditions of the suspended pipe itself shall be taken into account. In addition, it is possible to add accessories such as reinforcing plates that prevent local overstress or excessive deformation of the pipe.
7.2.4 The pin hole of the single lifting plate shall be a double tapered hole with a small center of the lifting plate adapted to the swinging of the boom, a large end face of the lifting plate and a cone angle of 10°.
7.2.5 The main connection dimensions of the horizontal pipe section structure are shown in Figure C.1~C.10 and Table C.1~Table C.10 of Appendix C.
7.3 Riser pipe department
7.3.1 The selection and positioning of the riser hanger shall be included in the entire weight of the riser and the adjacent piping, hydraulic test load conditions, and pipeline temperature. Degree, other working load conditions and available support structure. Only one rigid support hanger should be used on the riser that is subject to expansion.
7.3.2 The design of the riser pipe section shall be accounted for by the eccentric load caused by the displacement of the pipe and/or the hanger and hanger, except for special design. Any of the cantilever of the pipe should be able to withstand the full load of the hanger.
7.3.3 The riser pipe clamp shall be provided with a bearing block between the pipe and the pipe clamp, and the bottom surface of each bearing block shall be on the same horizontal plane.
7.3.4 When using the riser and elbow to weld the pipe structure, the strength and stiffness conditions of the suspended pipe itself shall be taken into account. In addition, it is possible to add accessories such as reinforcing plates that prevent local overstress or excessive deformation of the pipe.
7.3.5 The pin hole of the riser welded finned plate and the riser tubular trunnion hanger hanging plate shall be small and hanging plate suitable for the swinging of the boom. Double tapered holes with large end faces and a cone angle of 10°.
7.3.6 The main connection dimensions of the riser pipe structure are shown in Figure C.11~C.12 and Table C.11~Table C.12 of Appendix C.
7.4 Rolling support
7.4.1 The bottom surface of the pipe structure of the rolling hanger shall conform to the bearing surface of the rolling member.
7.4.2 The contact temperature of the roller should not exceed 230 °C, and the surface temperature of the elastic coating should not exceed 150 °C.
7.4.3 Rolling parts consist of parts such as rollers, bearings or roller shafts.
7.4.4 The drum type includes a single cylindrical roller, a double cylindrical roller or a double cone roller.
7.4.5 The drum is made of cast iron or high-strength carbon steel. The roller shaft is made of stainless steel and polished. There is Teflon between the drum and the drum shaft. Bushing made of bronze composite material.
7.4.6 Horizontal pipe steel supports are used for single cylindrical roller components; pipe clamp saddles and welded saddles are used f...
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 73 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 5310Seamless steel tubes and pipes for high pressure boiler
- GB/T 17116.1Pipe supports and hangers - Part 1: Technical specification
- GB/T 17116.3Pipe supports and hangers - Part 3: Middle connection attachments and building structure attachments
- GB/T 17393Specification for thermal insulation for use in contact with austenitic stainless steel
GB/T 713 · GB 3274 · GB/T 3531 · GB/T 24511
Cited by
- GB/T 27880-2025Thermoprobe and pipe supports with thermoprobe
- GB/T 45472-2025Prefabricated insulation pipes for overhead and utility tunnel
- GB/T 17116.1-2018Pipe supports and hangers - Part 1: Technical specification
- GB/T 17116.3-2018Pipe supports and hangers - Part 3: Middle connection attachments and building structure attachments
Similar standards
GB/T 17116.1-2018|GB/T 17116.3-2018|GB/T 17116.2-1997|GB/T 17393-2008|GB/T 24511-2017|GB/T 5310-2017
Editions of GB/T 17116.2
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 17116.2-2018 | Pipe supports and hangers - Part 2: Pipe attachments | first revision | Current |
| GB/T 17116.2-1997 | Pipe supports and hangers - Part 2: Pipe attachments | first issue | Superseded |
This page sells the current edition, GB/T 17116.2-2018. Earlier editions are listed for reference only.
How to Buy GB/T 17116.2-2018
- 1Add to cart. Click the "Buy GB/T 17116.2-2018" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 17116.1-2018 — Pipe supports and hangers - Part 1: Technical specification
GB/T 17116.3-2018 — Pipe supports and hangers - Part 3: Middle connection attachments and building structure attachments
GB/T 17393-2008 — Specification for thermal insulation for use in contact with austenitic stainless steel
Secure payment via Stripe
Payments accepted
GB/T 17116.2-2018