GB/T 14048.7-2016Low-voltage switchgear and controlgear -- Part 7-1: Ancillary equipment -- Terminal blocks for copper conductors (English PDF)
This is a limited preview
Buy now to download the full PDF (26 pages)
Need quotation for your management?
Get a formal quotation for GB/T 14048.7-2016 in 30 minutes.
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China
Level / Type
National · Recommended
Issue date
February 24, 2016
Implementation date
September 1, 2016
Scope
GB/T 14048.7-2016 (Low-voltage switchgear and controlgear -- Part 7-1: Ancillary equipment -- Terminal blocks for copper conductors) is available as an English-translated PDF.
GB/T 14048.7-2016 — This part of GB 14048 specifies the installation of an electrical connection for copper conductors for use in industrial or similar applications on a support and Mechanical connection of threaded or non-threaded terminal block requirements.
This part applies to the rated voltage AC does not exceed 1000V1), frequency to 1000Hz or DC does not exceed 1500V circuit, with in the connection cross-sectional area of 0.2mm2 ~ 300mm2 (AWG24/600kcmil) with or without special processing of the round copper wire terminal Sub-row.
1) AC rated voltage 1140V electrical appliances can refer to this part of the implementation. The requirements for electrical performance and other requirements are determined by the manufacturer and the user.
Note.
AWG is an abbreviation for "American Wire Gauge" kcmil = 1000cmil 1cmil = 1 round ear = diameter 1 mil round area 1mil = 1/1000 inch the following products may use this section as a guide. --- need to install a special device on the wire terminal block, such as fast connection terminals or connection connections; - with the edge or tip puncture insulation to achieve direct contact with the wire terminal block, such as insulation transfer connections; --- Special types of terminal blocks, such as terminal blocks with diodes or rheostats or similar component brackets.
When referring to GB 14048.1-2012, the term "clamping element" is used in this section instead of "terminal".
Found what you need?
Document preview — GB/T 14048.7-2016
National Standard of the People's Republic of China
- ICS
- 29.120.60
- Classification
- K 30
- Replacing
- GB/T 14048.7-2006
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People 's Republic of China
Contents
- Preface
- Basic requirements
- 2 Terms and definitions
- Category
- 4 Features
- 5 Product information
- 6 Normal use, installation and transportation conditions
- 7 Structure and performance requirements
- 8 Test
- Appendix A Blank
- Appendix B (informative) Terms and Conditions relating to manufacturers and user agreements
- Appendix C Blank
- Appendix D (normative appendix) Additional requirements for isolated terminal blocks for testing
- Reference
Foreword
GB 14048 "Low-voltage switchgear and control equipment" is divided into the following 21 parts.
- Part 1. General;
- Part 2. Circuit breakers;
- Part 3. switch, isolator, disconnector and fuse combination;
- Part 4-1. Contactors and motor starters Electromechanical contactors and motor starters (including motor protector);
- Part 4-2. Contactors and motor starters - AC semiconductor motor controllers and starters (including soft starters);
- Part 4-3. Contactors and motor starters - AC semiconductor controllers and contactors for non - motor loads;
- Part 5-1 Control circuit Electrical and switching elements Electromechanical control circuit appliances;
- Part 5-2. Control circuit appliances and switching element proximity switches;
- Part 5-3. Control circuit electronics and switching elements - Proximity switches (PDF) with definite function under fault conditions Claim;
- Part 5-4. Control circuit appliances and switching elements - Evaluation of performance of small capacity contacts - Special tests;
- Part 5-5. Control circuit appliances and switching elements - Electrical emergency braking devices with mechanical latch function;
- Part 5-6. Control circuit appliances and switching elements - DC interface (NAMUR) for proximity sensors and switching amplifiers;
- Part 5-7. Control circuit appliances and switching elements for approaching equipment with analog outputs;
- Part 5-8. Control circuit appliances and switching elements - Three enable switches;
- Part 5-9. Control circuit appliances and switching element flow switches;
- Part 6-1. Multifunctional electrical switchgear;
- Part 6-2. Multifunctional electrical appliances (equipment) control and protection switchgear (equipment) (CPS);
- Part 7-1. Terminal blocks for auxiliary devices for copper conductors;
- Part 7-2. Protective devices - Protection conductors for copper conductors - Terminal blocks;
- Part 7-3. Safety requirements for auxiliary device fuses terminal blocks;
- Part 8. Loaded thermal protection (PTC) control unit for rotating electrical machines.
This section is part 7-1 of GB 14048.
This part is drafted in accordance with the rules given in GB/T 1.1-2009.
This part of the replacement GB/T 14048.7-2006 "Low-voltage switchgear and controlgear Part 7-1. auxiliary device copper conductor connection Line terminal block ". The technical differences between this part and GB/T 14048.7-2006 are.
--- "Additional information" should be added by the manufacturer's content "g) Conventional free air heating current (Ith)" and increased the annotations of the item;
--- Refer to 7.1.3 "Electrical Clearance and Creepage Distance" and 7.2.2 "Dielectric Properties" on "Terminal blocks without Uimp specified" its minimum clearance and creepage distances are described in Appendix A "." The manufacturer does not specify the rated impulse withstand Voltage Uimp terminal block, the Uimp minimum see GB 14048.1-2012 Appendix H ";
--- 7.1.4 "Identification and marking of terminals" Added "For the identification of terminal blocks, yellow-green mixed colors are not allowed" Last paragraph;
--- 7.1.5 "Non-normal heat and fire", after the first paragraph to add a sentence "GB 14048.1-2012 7.1.2.2 In addition to note, not applicable to this part ";
--- 7.1.6 "rated cross-sectional area and rated connection capacity", in the first paragraph after the addition of a "consistency verification can be based on 8.3.3.4 Test proceeding ";
--- 8.2 "General requirements for testing", add the last paragraph "If one of the terminal blocks can not pass one of the tests Test, you need to repeat the test on the second set of terminal blocks, then all the terminal blocks should be repeated through the test. If this is the one Test is a part of the test sequence, then all the test sequence should be repeated ";
--- 8.3.2, 8.3.3.2, 8.4.5 and 8.4.6 on the "thread diameter less than or equal to 2.8mm screw-type clamping parts, tightening torque in accordance with the provisions of Table C.1 or the manufacturer's specified value "are changed to" tightening torque should be GB 14048.1-2012 in Table 4 of the specified value, or according to the manufacturer specified higher torque value. ";
--- 8.3.3.4 "Verification of rated cross-sectional area and rated connection capability" Finally added a new section "Theoretical diameter of the largest conductor see GB 14048.1-2012 in Table 7a (Correspondence between conductor cross-sectional area and diameter) ";
In the original appendix A, appendix B, appendix C, delete appendix A and appendix C, retain appendix B, and add new appendix D (Normative). Additional requirements for isolating terminal blocks for testing.
This part uses the re-drafting method to modify the use of IEC 60947-7-1.:2009 (version 3.0) "Low-voltage switchgear and control equipment 7-1 part. auxiliary device copper conductor terminal block ".
The technical differences between this part and IEC 60947-7-1.:2009 are.
--- on the normative reference documents to GB 14048.1-2012 low-voltage switchgear and control equipment Part 1. General (IEC 60947-1.:2011, MOD) instead of IEC 60947-1.:2007;
--- AC rated voltage 1140V electrical appliances can refer to this part of the implementation of the electrical performance requirements by the manufacturer and the user association to determine;
- According to China's environmental and material requirements, supplemented by the relevant requirements of the damp-heat performance (7.1.7) and its test method (8.3.3.6) and in the Appendix D made the appropriate editorial changes, that is, the clause No. D.7.1.7 changed to D.7.1.8;
--- For ease of understanding, add a note to the definition of "Terminal block", indicating that the terminal block in this section is made up of multiple wiring Terminal block combination;
--- For ease of understanding, add the markings to the title of the Appendix D "Test Isolated Terminal Blocks" Also called 'Switch Type Terminals Row "or" isolated terminal strip "and so on.
This part is made by China Electrical Equipment Industry Association.
This part of the national low-voltage electrical appliances Standardization Technical Committee (SAC/TC189) centralized.
This part is responsible for the drafting unit. Shanghai Electric Research Institute.
This part participates in the drafting unit. Phoenix China Investment Co., Ltd., Weidmüller Electric (Shanghai) Co., Ltd., Shanghai Engineering Technology University of Technology, Zhejiang Province, high and low voltage electrical product quality inspection center, Shanghai electrical equipment testing.
This part of the main drafters. Zhang Lili, Huang Jingye, Wu Qingyun, Zhu Shiming, Wang Chengping, Pan Ying, Lin Jie, Sun Jinfeng this part of the previous version of the standard to replace the release of the situation.
--- GB 14048.7-1998, GB/T 14048.7-2006.
Low-voltage switchgear and controlgear - Part 7-1.
Auxiliary device copper conductor terminal block
1 Basic requirements
1.1 Scope
This part of GB 14048 specifies the installation of an electrical connection for copper conductors for use in industrial or similar applications on a support and Mechanical connection of threaded or non-threaded terminal block requirements.
This part applies to the rated voltage AC does not exceed 1000V1), frequency to 1000Hz or DC does not exceed 1500V circuit, with in the connection cross-sectional area of 0.2mm2 ~ 300mm2 (AWG24/600kcmil) with or without special processing of the round copper wire terminal Sub-row.
1) AC rated voltage 1140V electrical appliances can refer to this part of the implementation. The requirements for electrical performance and other requirements are determined by the manufacturer and the user.
Note. AWG is an abbreviation for "American Wire Gauge" kcmil = 1000cmil 1cmil = 1 round ear = diameter 1 mil round area 1mil = 1/1000 inch the following products may use this section as a guide.
--- need to install a special device on the wire terminal block, such as fast connection terminals or connection connections;
- with the edge or tip puncture insulation to achieve direct contact with the wire terminal block, such as insulation transfer connections;
--- Special types of terminal blocks, such as terminal blocks with diodes or rheostats or similar component brackets.
When referring to GB 14048.1-2012, the term "clamping element" is used in this section instead of "terminal".
1.2 Normative references
The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document.
GB/T 5169.5-2008 Fire hazard testing for electric and electronic products - Part 5. Test flame flame flame test method, Confirmation of test methods and guidelines (IEC 60695-11-5.:2004, IDT) GB 14048.1-2012 Low - voltage switchgear and controlgear - Part 1. General (IEC 60947-1.:2011, MOD) ISO 4046-4.:2002 Glossary of paper, cardboard, pulp and related terms - Part 4. Paper and board grades and conversion products
2 Terms and definitions
The terms and definitions defined in GB 14048.1-2012 and the following terms and definitions apply to this document.
Terminal block an insulating member having one or more terminal blocks which are insulated from each other and intended to be mounted on a holder.
Note. The terminal block (terminalblocks) that appear in this section is a combination of multiple terminal blocks.
Rated cross-section the maximum cross-sectional area of all connectable types of conductors specified by the manufacturer, the wires are hard wires (single-core and multi-strand) and cord
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 26 pages — is available in the English PDF.
Referenced standards
Normative references
IEC 60695 · GB 14048.1-2012 · IEC 60947 · ISO 4046
Cited by
- GB/T 37410-2019Technical specifications of junction box for terrestrial solar-photovoltaic modules
- JB/T 4261-2019Low-voltage switchgear and controlgear assemblies - Terminology of accessories
- JB/T 6330-2019TG1 tubular terminals
- GB/T 14048.8-2016Low-voltage switchgear and controlgear -- Part 7-2: Ancillary equipment -- Protective conductor terminal blocks for copper conductors
- GB/T 32499-2016Connecting devices -- Devices for the connection of aluminium conductors in clamping units of any material and copper conductors in aluminium bodied clamping units
- JB/T 12195-2015Twin-rail trolley overhead conveyors
How to Download GB/T 14048.7-2016
- 1
Add to cart
Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.
- 2
Checkout
Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).
- 3
Instant delivery (0–9 sec)
Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4
Invoice included
A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 5169.5-2008 — Fire hazard testing for electric and electronic products -- Part 5: Test flames -- Needle test method -- Apparatus, confirmatory arrangement and guidance
GB/T 14048.11-2024 — Low-voltage switchgear and controlgear - Part 6-1: Multiple function equipment - Transfer switching equipment
GB/T 14048.12-2025 — Low-voltage switchgear and controlgear - Part 4-3: Contactors and motor-starters - Semiconductor controllers and semiconductor contactors for non-motor loads
Secure payment via Stripe