Scope
GB/T 12970.4-2009 is the English-translated version of 电工软铜绞线 第4部分:铜电刷线.
GB/T 12970.4-2009 is the Chinese national standard on flexilbe copper stranded conductors for electrical purposes - part 4: copper wires for electric brush, in the field of electrical engineering. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 19 March 2009 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 December 2009. Classification: ICS 29.060.10, CCS K11. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Document preview — GB/T 12970.4-2009
National Standard of the People's Republic of China
- ICS
- 29.060.10
- Classification
- K11
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- 1 Scope
- 2 Normative references
- 3 Models and specifications
- 4.1 Structure
- 4.2 Stranded
Foreword
GB/T 12970 "Electrical soft copper stranded" is divided into four parts.
--- Part 1. General requirements;
--- Part 2. soft copper wire;
--- Part 3. Flexible copper antenna;
--- Part 4. Copper wire brush. This section GB/T Part of 412,970. This Part replaces GB/T 12970.4-1991 "electrician soft copper stranded Part 4. Copper wire brush." This section compared with the GB/T 12970.4-1991 The main changes are as follows:
--- Remove section provides the structure and process requirements (before version
4.1.3 and 4.3.3);
--- Part of the process requirements of the structural adjustment (before version
4.3.1 and 4.3.2,
4.1.4 of this edition);
--- Modify the length of the manufacturing requirements (before version 4.8, this version 4.7). This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized. This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute. Participated in the drafting of this section. Shenzhen, China Cable Co., Ltd., Shanghai copper metal braid copper plant Jiang Su Jiangrun Copper Co. the company. The main drafters of this section. Liu Bin, party Peng, Zhang Peng, Chenya Fu, Liu Liming. This part of the standard replaces the previous editions are.
--- GB/T 12970.4-1991. Electrical soft copper wire Part 4. Copper wire brush
1 Scope
GB/T 12970.4-2009 is the Chinese national standard on flexilbe copper stranded conductors for electrical purposes - part 4: copper wires for electric brush, in the field of electrical engineering. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 19 March 2009 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 December 2009. Classification: ICS 29.060.10, CCS K11. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
GB/T 12970 provisions of this section copper brush wire model specifications, technical requirements and testing. This section applies to electrical and motor on the instrument line connecting copper wire brush. This section should be used in conjunction with the GB/T 12970.1-2009.
2 Normative references
The following documents contain provisions which, through reference
GB/T 12970 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.
GB/T 3048.4-2007 electrical wire and cable performance test methods - Part 4. Conductor DC resistance test
GB/T 4909.2-2009 Test methods for bare wires - Part 2. Measure
GB/T 4909.3-2009 Test methods for bare wires - Part 3. Tensile Test
GB/T 12970.1-2009 Electrical soft copper wire - Part 1. General requirements
3 Models and specifications
Copper brush wire models and specifications shown in Table 1. Table 1 copper wire brush type and specifications Model Name Nominal cross-sectional area mm2 TS TSX TSR Copper wire brush Tinned copper wire brush Soft copper wire brush
0.25 to 16
0.25 to 16
0.063 to 6.3 4. Technical Requirements
4.1 Structure
4.1.1 TS-type structure and TSX copper brush wire should meet the requirements of Table 2. Structure
4.1.2 TSR soft copper wire brush should be in accordance with Table 3.
4.1.3 There should be no shortage of brush line stocks, shares or broken strands damage phenomenon, the strands do not allow the entire shares welding.
4.1.4 lack of individual strands of wire should not exceed 3% of the total number of strands in a single line.
4.2 Stranded
4.2.1 wire brush to the outermost layer should be twisted to the right. Unless otherwise supply and demand sides of lay protocol, adjacent layers should contrast, the twisted strands by Specified by the manufacturer. Section
4.2.2 twisted inner diameter ratio should be less than 12, the outer stranding pitch diameter ratio should be 8 to 10. Section
4.2.3 strand diameter ratio should be less than 25.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 8 pages — is available in the English PDF.
Referenced standards
Normative references
- GB/T 3048.4-2007Test methods for electrical properties of electric cables and wires — Part 4: Test of DC resistance of conductors
- GB/T 4909.2-2009Test methods for bare wires - Part 2: Measurement of dimensions
- GB/T 4909.3-2009Test methods for bare wires - Part 3: Tensile test
- GB/T 12970.1-2009Flexible copper stranded conductors for electrical purposes - Part 1: General requirements
GB/T 12970
Similar standards
Editions of GB/T 12970.4
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 12970.4-2009 | Flexilbe copper stranded conductors for electrical purposes - Part 4: Copper wires for electric brush | current edition | Current |
| GB 12970.4-1991 | Flexible copper stranded conductors for electrical purposes Part 4:Copper brush wires | merged into this edition | Superseded |
This page sells the current edition, GB/T 12970.4-2009. Earlier editions are listed for reference only.
How to Buy GB/T 12970.4-2009
- 1Add to cart. Click the "Buy GB/T 12970.4-2009" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 12970.1-2009 — Flexible copper stranded conductors for electrical purposes - Part 1: General requirements
GB/T 12970.2-2009 — Flexible copper stranded conductors for electrical purposes - Part 2: Flexible copper stranded conductors
GB/T 12970.3-2009 — Flexible copper stranded conductors for electrical purposes - Part 3: Flexible copper wire for antenna
Secure payment via Stripe
Payments accepted
GB/T 12970.4-2009
$90.00