GB/T 11153-2012Test methods of laser power meter in lower-range (English PDF)
激光小功率计性能检测方法
Open the GB/T 11153-2012 preview as PDF
This is a limited preview
Buy now to download the full PDF (19 pages)
Issued by
General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Level / Type
National · Recommended
Issue date
December 31, 2012
Implementation date
June 1, 2013
Scope
GB/T 11153-2012 is the English-translated version of 激光小功率计性能检测方法.
GB/T 11153-2012 is the Chinese national standard on test methods of laser power meter in lower-range, in the field of metrology and measurement. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 31 December 2012 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 June 2013. Classification: ICS 17.180.99, CCS N30. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
Document preview — GB/T 11153-2012
National Standard of the People's Republic of China
- ICS
- 17.180.99
- Classification
- N30
Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China
Contents
- 1 Scope
- 2 Terms and definitions
- 2.4 Responsivity change during irradiation changeofresponsivityduringirradiation F
- 2.5 Responsivity variation with temperature temperaturedependenceofresponsivity F
- 2.6 Zero drift zerodrift F
Foreword
This standard rule according to GB/T 1.1-2009 given draft. This standard replaces GB/T 11153-1989 "laser power meter performance testing methods", compared with the GB/T 11153-1989 major change Of the following.
--- Modify the application of the criteria range (see Chapter 1, Chapter 1 of the 1989 edition);
--- Remove the source of the laser beam parameter space requirements (see the 1989 edition of 5.2a and 5.2c);
--- Laser power increased the standard and reference laser power requirements (see
--- Deleted the reference detector, the instrument display requirements (see the 1989 version of the 5.5,
--- Modify the basic detection device (Block) (see Fig. 1, 1989 edition of the FIG. 1);
--- Modify the response of the changes over time (see 5.7, 1989 edition, Chapter 12), removed from the response of the laser irradiation caused Detecting changes over time (see the 1989 edition 12.1);
--- Modify the response to the detection of the calibration uncertainty (see 59, Chapter 14 of the 1989 edition.);
--- Remove the Appendices A and B (see 1989 edition Appendix A and Appendix B). The standard proposed by the Ministry of Industry and Information Technology of the People's Republic of China. This standard by the National Standardization Technical Committee Electronic Measuring Instruments (SAC/TC153) centralized. This standard was drafted. Beijing Optoelectronics Technology Institute. The main drafters of this standard. full Chunyang, Lu Yaodong, Luo Zhijun. This standard superseded standard previously issued as follows:
--- GB/T 11153-1989. Laser power meter performance test method
1 Scope
GB/T 11153-2012 is the Chinese national standard on test methods of laser power meter in lower-range, in the field of metrology and measurement. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 31 December 2012 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 June 2013. Classification: ICS 17.180.99, CCS N30. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.
This standard provides for the power range of 0.1mW ~ 100mW laser power meter (referred to as the instrument) performance test method. This standard applies to 0.1mW ~ 100mW laser power meter development and production testing, other power range of the laser power measurement Test instrument can also reference.
2 Terms and definitions
The following terms and definitions apply to this document.
2.1 Responsiveness responsivity S (S = Y/X) Laser power output and generation Y input quantity X of the output of the quotient.
2.2 Responsivity with incident power changes dependenceofresponsitivityonradiantpower F
1 In laser power measurement range, because of the relative change in response to changes in laser power to be measured is generated.
2.3 Changes changeofresponsivityoverthedetectorsurface photosensitive surface detector responsivity F
2 The maximum relative change in the photosensitive surface of the detector responsivity of the points can also be defined relative to the photosensitive surface of each labeled probe point responsiveness Standard deviation.
2.4 Responsivity change during irradiation changeofresponsivityduringirradiation F
3 The response of the laser power meter can be restored during the laser radiation generated by the relative change.
2.5 Responsivity variation with temperature temperaturedependenceofresponsivity F
4 Laser Power Meter relative changes within the specified ambient temperature responsiveness can be restored.
2.6 Zero drift zerodrift F
5 Showing the value of laser power meter is the relative change in the absence of any other laser and light radiation over time.
2.7 Responsiveness caused by the storage of change over time changeofresponsivitybystorage F
6 Responsiveness unrecoverable laser power meter storage conditions to produce a corresponding change.
......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 19 pages — is available in the English PDF.
Similar standards
Editions of GB/T 11153
| Edition | Title | Revision | Status |
|---|---|---|---|
| GB/T 11153-2012 | Test methods of laser power meter in lower-range | current edition | Current |
| GB 11153-1989 | testing method of laser power meter in low range | merged into this edition | Superseded |
This page sells the current edition, GB/T 11153-2012. Earlier editions are listed for reference only.
How to Buy GB/T 11153-2012
- 1Add to cart. Click the "Buy GB/T 11153-2012" button on this page. You can add more standards before checkout.
- 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
- 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
- 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.
Related Standards
GB/T 47310-2026 — Determination of total silicon, aluminium, iron, potassium, sodium, calcium, magnesium, manganese, phosphorus, titanium and sulfur in soil - Monochromatic excitation energy dispersive X-ray fluorescence spectrometry
GB/T 47321-2026 — Specification for the warning data exchange of the national emergency early warning dissemination system
GB/T 47293-2026 — Determination of available mercury in soil
Secure payment via Stripe
Payments accepted
GB/T 11153-2012
$160.00