Valid

GB/T 11016.2-2009Plastic or rubber insulated telephone cords - Part 2: Polyvinyl chloride insulated telephone cords (English PDF)

塑料绝缘和橡皮绝缘电话软线 第2部分:聚氯乙烯绝缘电话软线

Open the GB/T 11016.2-2009 preview as PDF

Preview — first pages of GB/T 11016.2-2009 (full document: 17 pages)

This is a limited preview

Buy now to download the full PDF (17 pages)

Issued by

General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Level / Type

National · Recommended

Issue date

March 19, 2009

Implementation date

December 1, 2009

Scope

GB/T 11016.2-2009 is the English-translated version of 塑料绝缘和橡皮绝缘电话软线 第2部分:聚氯乙烯绝缘电话软线.

GB/T 11016.2-2009 is the Chinese national standard on plastic or rubber insulated telephone cords - part 2: polyvinyl chloride insulated telephone cords, in the field of electrical engineering. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 19 March 2009 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 December 2009. Classification: ICS 29.060.20, CCS K13. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB/T 11016.2-2009

National Standard of the People's Republic of China

ICS
29.060.20
Classification
K13

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China

Contents

  • 1 Scope
  • 2 Normative references
  • 3 Models
  • 4 Specification

Foreword

GB/T 11016 "plastic or rubber insulated telephone cords" is divided into four parts.

--- Part 1. General requirements;

--- Part 2. PVC insulated telephone cords;

--- Part 3. Polypropylene insulated telephone cords;

--- Part 4. Rubber insulated telephone cords. This section GB/T Part of 211,016. This Part replaces GB/T 11016.2-1989 "plastic or rubber insulated telephone cords PVC insulated telephone cords." This section compared with the GB/T 11016.2-1989 The main changes are as follows:

--- Increase the "Normative references" (1989 edition no; Chapter 2 of this section);

--- According to GB/T 1.1-2000 requirements, the original standard format has been modified. Appendix A of this section is normative appendix, Appendix B is an informative annex. This part is proposed by the China Electrical Equipment Industrial Association. This part of the National Standardization Technical Committee Wire and Cable (SAC/TC213) centralized. This part of the unit responsible for drafting. Shanghai Electric Cable Research Institute. Participated in the drafting of this section. Hai Saike force on Optical Cable Co., Ltd., Ningbo, a boat Investment Group Co., Ltd., Wenzhou Yaohua Electric Communications Limited. The main drafters of this section. Song Jie, Chen Jiande, Wang Qingsong, Xinxiu Dong, Ye Qinghua, Lu Xiang, Geely, Zou Ye Long, Meng Qingfeng, Gao Huan. This part of the standard replaces the previous editions are.

--- GB/T 11016.2-1989. Plastic or rubber insulated telephone cords Part 2. PVC insulated telephone cords

1 Scope

GB/T 11016.2-2009 is the Chinese national standard on plastic or rubber insulated telephone cords - part 2: polyvinyl chloride insulated telephone cords, in the field of electrical engineering. The /T suffix marks it as a recommended standard: it is not compulsory by itself, but it becomes binding as soon as a contract, a tender or a customer specification calls it up - which in practice is how most foreign buyers meet it. It was issued on 19 March 2009 by the General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China; Standardization Administration of China, and has been in force since 1 December 2009. Classification: ICS 29.060.20, CCS K13. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

GB/T 11016 provisions of this part of the PVC insulated telephone cords product variety, technical requirements, test methods and inspection rules. This section applies to the telephone base and the telephone connection handle or connection box PVC insulated telephone cords. PVC insulated telephone cords in addition to meeting the requirements of this part, it must also comply with GB/T 11016.1-2009 the corresponding requirements.

2 Normative references

The following documents contain provisions which, through reference

GB/T 11016 in this section constitute provisions of this section. For dated reference documents Member, all subsequent amendments (not including errata content) or revisions do not apply to this section, however, encouraged to reach under this section Parties to research agreement to use the latest versions of these documents. For undated reference documents, the latest versions apply to this section.

GB/T 2951.11-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 11. General test side Law

--- Measurement of thickness and overall dimensions of mechanical tests ( IEC 60811-1-1.2001, IDT)

GB/T 2951.14-2008 cable insulation and sheathing materials test methods - Part 14. General test methods for low temperature

IEC 60811-1-4. 1985, IDT)

GB/T 2951.31-2008 cable and the cable Common test methods for insulating and sheathing materials - Part 31. Polyvinyl chloride mixture Special test methods for high temperature pressure test

--- resistance to cracking (

IEC 60811-3-1. 1985, IDT)

GB/T 3048.4-2007 electrical wire and cable performance test methods - Part 4. Conductor DC resistance test

GB/T 3048.5-2007 electrical wire and cable performance test methods - Part 5. Insulation resistance test

GB/T 3048.8-2007 electrical wire and cable performance test methods - Part 8. AC voltage test

GB/T 4909.2-2009 Test methods for bare wires - Part 2. Measure

GB/T 11016.1-2009 plastic or rubber insulated telephone cords - Part 1. General requirements

3 Models

PVC insulated telephone cords of the model shown in Table 1. The telephone cord suitable for use at -10 °C ~ 40 °C indoor conditions. Table 1 PVC insulated telephone cords models Model Name Purpose HRV PVC insulated telephone cords connected to the telephone base and terminal box HRVB PVC insulated flat telephone cord to connect the telephone base and terminal box HRVT PVC insulated spring shaped telephone cord to connect the telephone base and the telephone handle

4 Specification

PVC insulated telephone cords specifications as shown in Table 2. Table 2 PVC insulated telephone cords specifications Model HRV HRVB HRVT Core number 2 2,3,4 3,4,5

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 17 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB/T 11016.2

EditionTitleRevisionStatus
GB/T 11016.2-2009Plastic or rubber insulated telephone cords - Part 2: Polyvinyl chloride insulated telephone cordscurrent editionCurrent
GB 11016.2-1989Plastic or rubber insulated telephone cords; Part 2:Polyvinyl chloride insulated telephone cordsmerged into this editionSuperseded

This page sells the current edition, GB/T 11016.2-2009. Earlier editions are listed for reference only.

How to Buy GB/T 11016.2-2009

  1. 1Add to cart. Click the "Buy GB/T 11016.2-2009" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
17 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB/T 11016.2-2009

$140.00

$120.00for partners