Scope

GB 9706.19-2000 (Medical electrical equipment. Part 2: Particular requirements for the safety of endoscopic equipment) is available as an English-translated PDF.

GB 9706.19-2000 — Addition. This Particular Standard specifies requirements for the safety of ENDOSCOPIC EQUIPMENT and its INTERCONNECTION CONDITIONS with ENDOSCOPICALLY-USED ACCESSORIES.

NOTE - As the General Standard does not give requirements for the safety of APPLIED PARTS of different MEDICAL ELECTRICAL EQUIPMENT when used together, this standard gives requirements for specific INTERCONNECTION CONDITIONS commonly encountered during the Use Of ENDOSCOPES.

Found what you need?

Document preview — GB 9706.19-2000

National Standard of the People's Republic of China

ICS
11.040.50
Classification
C 40

Issued by: State Bureau of Quality and Technical Supervision

Contents

  • Foreword...3
  • IEC Foreword...4
  • 1 Scope and Object...5
  • 2 Terminology and Definitions...7
  • 3 General Requirements...8
  • 4 General Requirements for Tests...9
  • 5 Classification...9
  • 6* Identification, Marking and Documents...9
  • 20 Dielectric Strength...12
  • 21* Mechanical Strength...12
  • 22 Moving Parts...12
  • 25 Expelled Parts...13
  • 26 Vibration and Noise...13
  • 27 Pneumatic and Hydraulic Power...13
  • 28 Suspended Masses...13
  • 36 Electromagnetic Compatibility...14
  • 42 Excessive Temperatures...14

Foreword

This Standard equivalently adopts IEC 60601-2-18.1996 Medical Electrical Equipment – Part

2 Particular Requirements for the Safety of Endoscopic Equipment.

This Standard is used in conjunction with international standard IEC 60601-1 Medical

Electrical Equipment – Part 1.General Requirements for Safety, which has been transferred

into national standard GB 9706.1-1995.IEC 60601-1-1 Medical Electrical Equipment – Part

1 General Requirements for Safety has been approved.

Annex L of this Standard is for reference.

Annex AA of this Standard is informative.

This Standard was proposed by National Medical Products Administration.

This Standard shall be under the jurisdiction of National Technical Subcommittee on Medical

Optics and Instrument of Standardization Administration of China.

Drafting organization of this Standard. Hangzhou Center for Medical Device Quality

Supervision and Testing of National Medical Products Administration.

Chief drafting staffs of this Standard. He Tao, Wen Yan, and Zhen Hui.

Medical Electrical Equipment – Part 2.Particular

Requirements for the Safety of Endoscopic Equipment

This Particular Standard equivalently adopts IEC 60601-2-18.1996 Medical Electrical

Equipment – Part 2.Particular Requirements for the Safety of Endoscopic Equipment; and

shall be used in conjunction with GB 9706.1-1995 Medical Electrical Equipment - Part 1.

General Requirements for Safety.

SECTION ONE – GENERAL

This Clause of and classification clause of the General Standard apply, except as follows.

1 Scope and Object

This clause of the General Standard applies, except as follows.

1.1 Scope

Addition.

This Particular Standard specifies requirements for the safety of ENDOSCOPIC EQUIPMENT

and its INTERCONNECTION CONDITIONS with ENDOSCOPICALLY-USED

ACCESSORIES.

NOTE - As the General Standard does not give requirements for the safety of APPLIED PARTS

of different MEDICAL ELECTRICAL EQUIPMENT when used together, this standard gives

requirements for specific INTERCONNECTION CONDITIONS commonly encountered

during the Use Of ENDOSCOPES.

1.2 Object

Replacement.

The object of this Particular Standard is to establish particular requirements for the safety of

ENDOSCOPIC EQUIPMENT and enable parts Of ENDOSCOPIC EQUIPMENT to be tested

together or individually.

1.3 Particular Standards

Addition.

This Particular Standard amends and supplements a set of IEC publications, hereinafter referred

to as "General Standard", consisting of GB 9706.1-1995 Medical electrical equipment - Part

1 General requirements for safety; IEC 60601-1.1998Medical electrical equipment - Part 1.

General requirements for safety, amendment 2; IEC 60601-1-1.1992 Medical electrical

equipment - Part 1.General requirements for safety, 1.Collateral Standard. Safety

requirements for medical electrical systems, amendment 1; and IEC 60601-1-2.1993 Medical

electrical equipment - Part I. General requirements for safety, 2.Collateral standard.

Electromagnetic compatibility - Requirements and tests.

GB 9706.1-1995 and IEC 60601-1.1998 Amendment 2 is referred to in this Particular Standard

either as the "General Standard" or as the "General Requirement(s)"; and IEC 60601-1-1.1992

and IEC 60601-1-2.1993 as the "Collateral Standards".

The term "this Standard" covers this Particular Standard, used together with the General

Standard and Collateral Standards.

The numbering of sections, clauses and subclauses of this Particular Standard corresponds with

that of the General Standard. The changes to the text of the General Standard are specified by

the use of the following words.

"Replacement" means that the clause or subclause of the General Standard is replaced

completely by the text of this Particular Standard.

"Addition" means that the text of this Particular Standard is additional to the requirements of

the General Standard.

"Amendment" means that the clause of subclause of the General Standard is amended as

indicated by the text of this Particular Standard.

Subclauses or figures which are additional to those of the General Standard are numbered

starting from 101, additional annexes are lettered AA, BB, etc., and additional items aa), bb),

etc.

Clauses and subclauses to which there is a rationale are marked with an asterisk *. These

rationales can be found in an informative annex AA. Annex AA is not part of this Particular

Standard and only gives additional information; it can never be the subject of testing.

Where there is no corresponding section, clause or subclause in this Particular Standard, the

section, clause or subclause of the General Standard or Collateral Standard applies without

modification.

Where it is intended that any part of the General Standard or Collateral Standards, although

possibly irrelevant, is not to be applied, a statement to that effect is given in this Particular

Standard.

A requirement of this Particular Standard replacing or modifying requirements of the General

......

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 14 pages — is available in the English PDF.

Referenced standards

Cited by

How to Download GB 9706.19-2000

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
14 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 9706.19-2000

$390.00