YY/T 0283-2007Large intestine fiber endoscope (English PDF)

纤维大肠内窥镜

Preview PDF

This is a limited preview

Buy now to download the full PDF (26 pages)

Need quotation for your management?

Get a formal quotation for YY/T 0283-2007 in 30 minutes.

Issued by

NMPA

Level / Type

Industry · Recommended

Issue date

July 2, 2007

Implementation date

March 1, 2008

Scope

YY/T 0283-2007 is the English-translated version of 纤维大肠内窥镜.

YY/T 0283-2007 is the Chinese pharmaceutical industry standard for large intestine fibre endoscopes, sigmoidoscopes and colonoscopes used to examine and diagnose the colon and in related surgery.

It sets the working conditions and the requirements for the surface and joints, the optical system, with illumination of at least 8 000 lx, resolution of at least 3.51 lp/mm and limits on broken fibres, the water supply and suction system, the bending mechanism and its lock, sealing of the waterproof type at 22 kPa, length marking, biocompatibility, environmental testing under GB/T 14710 and electrical safety under the GB 9706 series.

Test methods, inspection rules, marking, instructions, packaging, transport and storage complete it. It revises YY/T 0283-1995. Issued on 2 July 2007, it has applied since 1 March 2008.

Found what you need?

Document preview — YY/T 0283-2007

National Standard of the People's Republic of China

Replacing
YY/T 0283-1995

Issued by: National Medical Products Administration of the People's Republic of China

Contents

  • Foreword3
  • 1 Scope4
  • 2 Normative references4
  • 3 Classification5
  • 4 Requirements5
  • 5 Test methods8
  • 6 Inspection rules14
  • 7 Marking and operation instructions15
  • 8 Package, transportation and storage16
  • Annex A18
  • Annex B25
  • Annex C26

Foreword

This Standard is the revision of YY/T Q283-1995 "Large Intestine Fiber Endoscope".

Compared with YY/T 0283-1995, main differences in this Standard are as follows.

- Specify the name of standard;

- Add the classification of waterproof ability of product;

- Increase the quantity index of broken-fiber number;

- Add the coincidence requirements between illumination source and observation view-field;

- Modify the requirements on product marking;

- Add the requirements on waterproof product;

- Add the requirements on biocompatibility;

- Modify the test method of view-field angle;

- Delete the requirements on sealing property in previous standard;

- Add Annex A (Normative).

For electrical connection part, it shall comply with GB 9706.1-1995 "Medical Electrical Equipment - Part 1: General Requirements for Safety", GB 9706.4-1999 "Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of High Frequency Surgical Equipment", and GB 9706.19-2000 "Medical Electrical Equipment - Part 2: Particular Requirements for the Safety of Endoscopic Equipment". The details are given in Annex A (Normative).

Annex A and B of this Standard are normative; Annex C is informative. This Standard replaces YY/T 0283-1995, since the date of issuance. This Standard was approved by State Food and Drug Administration.

This Standard shall be under jurisdiction of National Technical Committee on Medical Optical Instruments of Standardization Administration of China.

Drafting organization of this Standard. Medical Optical Equipment Factory of Shanghai Medical Instruments Co., Ltd.

Main drafters of this Standard. Li Yafen, Sun Qi, and Shen Tianming. This Standard was first-time published in November 1995.

1 Scope

This Standard specifies the classification, marking, requirements, test methods, inspection rules, identification, operation instructions, packaging, transportation, and storage of large intestine fiber endoscope.

This Standard is applicable to large intestine fiber endoscope (hereinafter referred as fiber endoscope). This product is used to the examination and diagnosis of large intestine cavity and can also be used in the relevant surgical operation.

2 Normative references

The provisions in following documents become the provisions of this Standard through reference in this Standard. For dated references, the subsequent amendments (excluding corrections) or revisions do not apply to this Standard, however, parties who reach an agreement based on this Standard are encouraged to study if the latest versions of these documents are applicable. For undated references, the latest edition of the referenced document applies.

GB/T 191-2008 Packaging - Pictorial marking for handling of goods

GB/T 2829-2002 Sampling procedures and tables for periodic inspection by attributes (Apply to inspection of process stability)

GB 9706.1-1995 Medical electrical equipment - Part 1: General requirements for safety

GB 9706.4-1999 Medical electrical equipment - Part 2: Particular requirements for the safety of high frequency surgical equipment

GB 9706.19-2000 Medical electrical equipment - Part 2: Particular requirements for the safety of endoscopic equipment

GB 11244-2005 General requirements for the medical endoscope and endoscope accessories

GB/T 14710-1993 The environmental requirements and test methods for medical electrical equipment

GB/T 16886.1-2001 Biological evaluation of medical devices - Part 1: Evaluation and testing

3 Classification

3.1 Fiber endoscope includes sigmoidoscope and colonoscope.

4 Requirements

4.1 Working conditions

The normal working conditions of fiber endoscope.

4.2 Surface requirements

4.2.1 The coherence of each connecting part shall be reliable and fixed. The welding part shall be flat without fake welding, de-soldering or overlaying.

4.2.2 The external surface of head-end, bend part and inserted hose part shall be flat and smooth, without obvious bulge, scratch or burr.

4.3 Performance of optical system

4.3.1 Illumination shall not be less than 8 000 lx, at working distance.

4.3.2 Resolution ratio shall not be lower than 3.51 lp/mm, at working distance.

4.3.3 The quantity of the broken-fiber of coherent fiber bundle must not be more than 5 pieces, within 50% of view-field scope. The total quantity must not be more than 10 pieces.

4.4 Water supply and suction system

4.4.1 Supplied water can wash the surface of lens. The flow of supplied water shall not be lower than 45 mL/min.

4.5 Bend-angle operation system

4.5.1 Bend-angle locking structure shall be able to tightly lock the hand-wheel. The bend-angle part shall be able to do bend action under locking state. After locking is released, it shall not affect the operating function of bend-angle hand-wheel. There is no too-tight, too loose or stuck-up phenomenon during operation.

4.6 Sealing

4.6.1 Fiber endoscope shall be soaked in water as a whole. Its internal cavity can withstand pressure of 22 kPa for 3 min; without air leakage (applicable to waterproof type).

4.6.2 The head-end part shall be used within 20°C ~ 40°C. The surface of optical parts shall not generate mist due to temperature variation that affect observation.

4.7 Marking

4.7.1 The inserted flexible tube shall be marked with length marking. The marked line and words shall be legible.

4.9 Biocompatibility

Fiber endoscope is a medical device which contacts with mucous membrane for short-term in accordance with GB 16886.1-2001. The surface of the part inserted into human body shall be made of materials which are proved to conform to biocompatibility or pass the following tests.

4.11 Requirements on ambient test

Conform to atmosphere environmental test group II, mechanical environmental test group II and table 3 in GB/T 14710-1993.

4.12 Safety

Fiber endoscope shall conform to the relevant requirements in GB 9706.1-1995, GB 9706.4-1999 and GB 9706.19-2000. For details, refer to annex A (Normative).

5 Test methods

5.1 Surface requirements

Adopt visual inspection and hand-touch inspection to check the surface. It shall conform to Article 4.2.

5.2 Performance of optical system

5.2.1 Illumination test

5.2.1.1 Under the voltage of 220V, insert the illumination tester specified in Annex B (Normative) into the cold lighting surface (150W). Adjust the illumination value of cold light source to above 70 000 lx.

5.2.3 Broken-fiber test

Place a white paper with two circles drawn on it on the working surface; light it uniformly; observe from lens. The quantity of broken-fibers, within 50% of view-field and out of 50% of view-field shall conform to Article 4.3.3.

5.2.4 View-field angle test
5.2.4.1 Measuring instruments
5.2.5 Coincidence of illumination source and observation view-field

Visual inspection shall be conducted under the maximum illumination of the provided lamp in accordance with Article 4.3.5.

5.2.6 Clear observation range

Fix the endoscope; adjust the distance between objective lens and the observed object.

When it is at 5mm and 100mm positions, observe through the eyepiece of endoscope; it shall be able to clearly see 1.0mm-wide strip; it shall conform to Article 4.3.6.

5.3 Water supply and suction performance test

5.6 Marking

Adopt visual inspection to check whether the operation conform to Article 4.7.

5.7 Dimensions

Measured by general measuring tools, it shall conform to Article 4.8.

5.8 Biocompatibility test

5.8.1 Cytotoxicity shall be tested in accordance with the method specified in Chapter 8 of GB/T 16886.5-2003. Cytotoxicity shall conform to the requirements in Article 4.9.1.

5.10 Environmental test

Environmental test shall be conducted in accordance with the relevant requirements in GB/T 14710-1993 and Article 4.11 of this Standard.

5.11 Safety test

Safety test shall be conducted in accordance with the methods specified in GB 9706.1-1995, GB 9706.4-1999, and GB 9706.19-2000. It shall conform to the requirements in Article 4.12.

6 Inspection rules

6.1 Classification of inspection

The inspections of fiber endoscope are divided into exit-factory inspection and type inspection.

6.2 Exit-factory inspection

6.2.1 Product can be delivered out of factory after being confirmed as qualified through exit-factory inspection.

6.3 Type inspection

6.3.1 In case of the following circumstances, type inspection shall be conducted.

6.4 Biocompatibility evaluation

6.4.1 In case of the following circumstances, biocompatibility evaluation shall be conducted.

6.4.2 When conducting biocompatibility evaluation, select the samples according to test needs. All of samples shall pass inspection.

7 Marking and operation instructions

7.1 Marking

7.1.1 Fiber endoscope shall have the following marks.

7.1.2 Product qualification certificate shall have the following marks.

7.1.3 Outer package shall have the following marks.

7.2 Operation instruction

It shall conform to the requirements specified in No. 10 "Management Regulations on Manual, Labelling, and Packaging Logo of Medical Instruments" issued by China Food and Drug Administration, and the relevant requirements in GB 9706.1-1995 and GB 9706.19-2000.

8 Package, transportation and storage

8.1 Package

8.2 Transportation

It shall conform to the relevant requirements in order contract.

8.3 Storage

The packed fiber endoscope shall be stored in the well-ventilated indoor environment where is free of corrosive gas, with the relative humidity not exceeding 80%. […]

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 26 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of YY/T 0283

EditionTitleRevisionStatus
YY/T 0283-2007Large intestine fiber endoscopecurrent editionCurrent
YY/T 0283-1995Large intestine fiber endoscopeprevious editionSuperseded

This page sells the current edition, YY/T 0283-2007. Earlier editions are listed for reference only.

How to Download YY/T 0283-2007

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
26 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

YY/T 0283-2007

$135.00