Scope

GB 5135.8-2003 is the English-translated version of 自动喷水灭火系统 第8部分: 加速器.

GB 5135.8-2003 is Part 8 of the Chinese national standard series on automatic sprinkler systems and specifies the requirements, test methods, inspection rules, marking, instructions for use, packaging, transport and storage of accelerators, the quick-opening devices that release the air from a dry pipe alarm valve to shorten its opening time.

It applies to accelerators used with dry pipe alarm valves and dry/wet alarm valves.

The requirements cover appearance, a rated working pressure of at least 1.2 MPa, corrosion-resistant materials, components and elastomeric sealing elements, leakage and deformation at twice the rated working pressure for 5 min, an operating time not exceeding 30 s, air static pressure of 0.7 MPa, an equalisation time not exceeding 3 min, anti-flooding devices and an 800 °C fire resistance test; Clause 5 gives the matching test methods and Clause 6 the factory and type inspection, the sampling scheme (Figure 1) and the judgement rules.

Clauses 4 and 6 are mandatory and the rest is recommended. It was developed from GA 80-1994, which it repeals, adding requirements on packaging, transport and storage.

It was issued on 8 October 2003 and has been in force since 1 May 2004. Classification: ICS 13.220.10, CCS C83. The document runs to 7 pages, delivered complete in English translation.

Found what you need?

Document preview — GB 5135.8-2003

National Standard of the People's Republic of China

ICS
13.220.10
Classification
C83

Issued by: General Administration of Quality Supervision, Inspection and Quarantine of the People's Republic of China

Contents

  • Foreword
  • 1 Scope
  • 2 Normative references
  • 3 Terms and definitions
  • 4 Requirements
  • 5 Test methods
  • 6 Inspection rules
  • 7 Marking and instructions for use
  • 8 Packaging, transport and storage

3 Terms and definitions

4 Requirements

5 Test methods

6 Inspection rules

7 Marking and instructions for use

8 Packaging, transport and storage

Foreword

Clauses 4 and 6 of this part are mandatory; the rest is recommended.

GB 5135, Automatic sprinkler system, is at present planned to be divided into 15 parts:

- Part 1: Sprinklers;

- Part 2: Wet alarm valves, retard chambers and water motor alarms;

- Part 3: Water spray nozzles;

- Part 4: Dry pipe valves;

- Part 5: Deluge valves;

- Part 6: General valves;

- Part 7: Water flow indicators;

- Part 8: Accelerators;

- Part 9: Early suppression fast response (ESFR) sprinklers;

- Part 10: Pressure switches;

- Part 11: Grooved pipe couplings and fittings;

- Part 12: Extended coverage sprinklers;

- Part 13: Water curtain nozzles;

- Part 14: Pre-action devices;

- Part 15: Residential sprinklers;

- ...

This part is Part 8 of GB 5135.

This part was developed on the basis of GA 80-1994, Automatic sprinkler system - Performance requirements and test methods for accelerators.

Compared with GA 80-1994, the main difference of this part is as follows:

- requirements on product packaging, transport and storage have been added.

GA 80-1994 is repealed from the date of implementation of this part.

This part was proposed by the Ministry of Public Security of the People's Republic of China.

This part is under the jurisdiction of Sub-committee 2 of the National Technical Committee for Fire Protection Standardization.

Drafting organisation of this part: Tianjin Fire Research Institute of the Ministry of Public Security.

Main drafters of this part: Chen Zemin, Zhang Qiang.

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 7 pages — is available in the English PDF.

Referenced standards

Similar standards

Editions of GB 5135.8

EditionTitleRevisionStatus
GB 5135.8-2003Automatic sprinkler system--Part 8: Acceleratorcurrent editionCurrent

This page sells the current edition, GB 5135.8-2003. Earlier editions are listed for reference only.

How to Download GB 5135.8-2003

  1. 1

    Add to cart

    Click "Download PDF" on this page and choose "Buy this standard". You can add more standards before checkout.

  2. 2

    Checkout

    Enter your email and billing details. Payment is processed securely by Stripe (cards or bank transfer). Prefer bank details? Request a quotation (min. order $300).

  3. 3

    Instant delivery (0–9 sec)

    Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.

  4. 4

    Invoice included

    A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
7 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 5135.8-2003

$145.00