Valid

GB 21518-2022Minimum allowable values of energy efficiency and energy efficiency grades for AC contactors (English PDF)

交流接触器能效限定值及能效等级

Open the GB 21518-2022 preview as PDF

Preview — first pages of GB 21518-2022 (full document: 10 pages)

This is a limited preview

Buy now to download the full PDF (10 pages)

Issued by

State Administration for Market Regulation; Standardization Administration of China

Level / Type

National · Mandatory

Issue date

December 29, 2022

Implementation date

January 1, 2024

Scope

GB 21518-2022 is the English-translated version of 交流接触器能效限定值及能效等级.

GB 21518-2022 is the Chinese national standard on minimum allowable values of energy efficiency and energy efficiency grades for ac contactors, in the field of energy and heat transfer engineering. It carries no /T suffix, which in the Chinese system means compliance is mandatory: a product or a practice within its scope has to meet it to be lawfully made, sold or carried out in China. It was issued on 29 December 2022 by the State Administration for Market Regulation; Standardization Administration of China, and has been in force since 1 January 2024. Classification: ICS 27.010, CCS F01. This page is published from the official record of the standard held by the Chinese standards administration: the identification, the dates, the classification and the issuing body are taken from there. The clause text, the tables and the numeric limits are in the document itself, which is delivered complete in English translation.

Document preview — GB 21518-2022

National Standard of the People's Republic of China

ICS
27.010
Classification
F01

Issued by: State Administration for Market Regulation; Standardization Administration of China

Contents

  • 2 Normative References
  • 3 Terms and Definitions
  • 5 Technical Requirements

Foreword

NATIONAL STANDARD OF THE PEOPLE'S REPUBLIC OF CHINA ICS

Replacing GB 21518-2008

Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for AC Contactors

8 Table of Contents Foreword ........................................................................................................................ 3

1 Scope ........................................................................................................................... 4

2 Normative References ................................................................................................. 4

3 Terms and Definitions ................................................................................................. 4

4 Energy Efficiency Grades ........................................................................................... 5

5 Technical Requirements .............................................................................................. 6

Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for AC Contactors 1 Scope

This document specifies the energy efficiency grades, minimum allowable values of energy efficiency, sampling, test and calculation methods for AC contactors (hereinafter referred to as contactors). This document is applicable to three-pole electromechanical, direct-acting integral contactors with a rated frequency of

50 Hz, a rated operating voltage of the main circuit of 1,000 V and below, a rated operating current of 6 A ~ 630 A, a rated control power supply voltage of the contactors of AC 440 V and below, and an application category of AC-3. This document does not apply to household and similar-purpose contactors with external power-saving devices and semi-conductor contactors (solid-state contactors). NOTE: the "direct-acting" type described in this document refers to products in which both the contact system and the electromagnetic system are direct-acting.

2 Normative References

The contents of the following documents constitute indispensable clauses of this document through the normative references in the text. In terms of references with a specified date, only versions with a specified date are applicable to this document. In terms of references without a specified date, the latest version (including all the modifications) is applicable to this document.

GB/T 14048.1 (TRANSLATOR NOTE: it should be

GB 14048.1) Low-voltage Switchgear and Controlgear - Part 1: General Rules

GB/T 14048.4 Low-voltage Switchgear and Controlgear - Part 4-1: Contactors and Motor-starters - Electromechanical Contactors and Motor-starters (including motor protector)

3 Terms and Definitions

The terms and definitions defined in GB 14048.1 and GB/T 14048.4, and the following terms and definitions are applicable to this document.

5 Technical Requirements

The minimum allowable values of energy efficiency of the AC contactors are Grade-3 energy efficiency in Table 1.

6 Test and Calculation Methods 6.1 Test Methods 6.1.1 When contactors of same frame size have different rated control power supply voltage (Us) and different main circuit rated operating current ( Ie), the test shall be carried out in accordance with the following mode: a) When the number of rated control power supply voltage specifications is less than 5, the contactors with the maximum rated control power supply voltage and the minimum rated operating current shall be selected for the test; b) When the number of rated control power supply voltage specifications is greater than or equal to 5, 5 samples shall be selected, one of which is the minimum rated control power supply voltage, one is the maximum rated control power supply voltage, and another three rated control power supply voltage specifications that the manufacturer considers to have a larger holding power. For each voltage specification, select the contactor with the minimum rated operating current for the test.

6.1.2 When the rated control power supply voltage of the contactors of same frame size is in a range, the test shall be carried out in accordance with the following mode. In addition, take the maximum value as the holding power of the wide voltage specification.

a) When the upper limit of the rated control power supply voltage range is twice the lower limit, or above, respectively carry out the test at the upper limit and the lower limit of the voltage range;

b) When the upper limit of the rated control power supply voltage range is less than twice the lower limit, carry out the test at the upper limit of the voltage range.

6.1.3 The accuracy of the voltmeter and ammeter for the measurement shall be Grade

0.2 or above.

--- The End - - -

......
This preview omits tables, figures, formulas and parts of the technical clauses. The complete document — 10 pages — is available in the English PDF.

Referenced standards

Normative references

GB/T 14048.1 · GB 14048.1 · GB/T 14048.4

Similar standards

Editions of GB 21518

EditionTitleRevisionStatus
GB 21518-2022Minimum allowable values of energy efficiency and energy efficiency grades for AC contactorscurrent editionCurrent
GB 21518-2008Minimum Allowable Values of Energy Efficiency and Energy Efficiency Grades for AC Contactorsprevious editionSuperseded

This page sells the current edition, GB 21518-2022. Earlier editions are listed for reference only.

How to Buy GB 21518-2022

  1. 1Add to cart. Click the "Buy GB 21518-2022" button on this page. You can add more standards before checkout.
  2. 2Checkout. Enter your email and billing details. Payment is processed securely by Stripe (cards, Apple Pay, Google Pay supported).
  3. 3Instant delivery (0–9 sec). Delivery is automatic: within seconds of payment you'll receive an email with a secure download link. The link stays valid for 72 hours.
  4. 4Invoice included. A tax invoice is attached to the confirmation email. Need a custom invoice? Contact us.

Related Standards

English PDF
10 pages
Instant delivery (0–9 sec)
Invoice included
View Cart

Secure payment via Stripe

Payments accepted

VisaMastercardAmerican ExpressApple PayGoogle PayStripe

GB 21518-2022

$95.00

$80.00for partners